Zhoukou General Blower Co., Ltd
Home>Products>9-04 type high-pressure centrifugal fan
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    15539485098
  • Address
    No. 37 Zhouxi Road, Chuanhui District, Zhoukou City, Henan Province
Contact Now
9-04 type high-pressure centrifugal fan
9-04 type high-pressure centrifugal fan
Product details
Application of 9-04 type high-pressure centrifugal blower
Scope of application of 9-04 type high-pressure centrifugal fan: In order to meet the needs of the development of power equipment in China, the 9-04 series high-pressure small flow centrifugal blower has been developed and successfully applied in Xinbei Thermal Power Plant and Panjin Oilfield. This blower is suitable for power plants, petroleum, environmental protection, aquaculture, metallurgy, ironmaking, and chemical systems. The temperature of the medium generally does not exceed 50 ℃ (up to 80 ℃), and the dust and hard particles contained in the medium do not exceed 150mg/m ³.

Related products:9-06 type high-pressure centrifugal fan
9-04 type high-pressure centrifugal fan type:
The blower is a single suction type, with 11 machine numbers including No6.3D, 7.1D, 8C, 9D, 10D, 11.2D, 12.5D, 5.6C, 6.3C, 7.1C, and 8C for 9-04;
Ventilation fans can be made in two forms: right-handed and left-handed. When viewed from one end of the motor and the impeller rotates clockwise, it is called a right-handed cyclone fan, represented by "right"; The counterclockwise rotation is called a left cyclone, represented by "left".
The transmission modes of the fan are C type and D type.
The outlet position of the fan is represented by the outlet angle of the casing, and both "left" and "right" can be made into three angles: 0 degrees, 90 degrees, and 180 degrees.
Structure of 9-04 high-pressure centrifugal fan:
The blower is mainly composed of an impeller, a casing, an air inlet, a base, and a transmission group.
1) Shell: Welded into a snail shaped shell with ordinary steel plates as a whole.
2) Impeller: The 9-04 type fan has a total of 40 long and short blades. All belong to the forward curved blade type. After the impeller is formed, it undergoes static and dynamic balance correction, so it runs smoothly.
3) Transmission group: composed of main shaft, bearing box, coupling, etc. The main shaft is made of high-quality steel, and the bearing housing is an integral structure. It is lubricated with rolling bearings and bearing grease. There are detachable sealing rings installed on both sides of the cover.
4) Air inlet: Made into a convergent streamlined overall structure, fixed to the front cover plate group with bolts.

9-04 High pressure centrifugal fanPerformance and Component Selection Table:

Machine number drive
way
rotational speed
/(r/min)
internet traffic
/(m3/h)
Full pressure/Pa inner power
/kW
motor Couplings GB/T
4323-1984
Foot screw GB/T
799-1988
(4 of them)
Nut GB/T
6170-2000
(4 of them)
Gasket GB/T
97.1-1985
(4 of them)
model power
/ kW
6.3 D 2900 191
223
254
268
316
350
382
8390
8350
8300
8250
8190
8110
8030
0.74
0.82
0.89
0.97
1.07
1.22
1.42
Y132S1-2 5.5
TL7 38×82
60×142
M12×300 M12 12
7.1 D 2900 273
318
364
410
455
501
546

10650
10600
10530
10470
10390
10290
10200

1.35
1.49
1.61
1.75
1.95
2.22
2.58
Y132S1-2 5.5
TL7 38×82
60×142
M12×300 M12 12
8 D 2900 391
456
521
586
651
716
781
13520
13460
13370
13300
13200
13070
12940
2.44
2.70
2.94
3.19
3.54
4.04
4.28
Y132S1-2 5.5
TL7 38×82
60×142
M12×300 M12 12
9 D 2930 556
649
742
834
927
1019
1112
17120
17050
16930
16830
16710
16550
16380
4.41
4.88
5.29
5.74
6.39
7.27
8.44
Y160M1-2 11
TL7 42×112
60×142
M12×300 M12 12
10 D 2940 763
890
1017
1144
1271
1398
1526
21130
21040
20900
20780
20630
20430
20230
7.46
8.26
9.72
10.81
12.31
14.29
Y160M1-2 11
TL7 42×112
60×142
M12×300 M12 12
Y160M2-2 15
Y180M-2 22
TL7 48×112
60×142
11.2 D 2950 1072
1250
1492
1608
1786
1965
2144
26510
26390
26210
26070
25880
25630
25380
13.16
14.56
15.79
17.13
19.05
21.71
25.19
Y180M-2 22 M12×300 M12 12
Y200L1-2 30
TL7 55×112
60×142
12.5 D 2970 1490
1738
1987
2235
2483
2731
2980
33010
32870
32660
32470
32240
31920
31610
22.79
25.20
27.34
29.68
32.99
37.58
43.61
Y200L1-2 37 M12×300 M12 12
Y250M-2 55
TL7 55×112
60×142
Machine number drive
way
rotational speed
/(r/min)
internet traffic
/(m3/h)

Total pressure
/Pa

inner power
/kW

motor V belt Main shaft pulley Electric motor pulley Electric motor guide rail section
model power
/kW
Model and quantity
Inner circumference/mm
Code specification Code specification Code (2 sets)
5.6 C 4640 210
245
280
315
350
385
420
16250
16200
16100
15900
15700
15600
1.58
1.75
1.90
2.06
2.34
2.67
3.20
Y132S1-2 5.5

B2

2000

B2

140×60

B2

224×38

ST0201×02
6.3 C 4688 299
349
399
449
499
549
599
20600
20500
20400
20200
20100
19900
19700

2.85
3.15
3.42
3.01
4.20

4.80
5.40

Y160M1-2 11

B3

2000

B2

140×60

B3

224×42

ST0201×03
7.1 C 4688 428
500
570
642
713
785
858

26100
26000
25800
25700
25300
25000

5.17
5.73
6.22
6.75
7.67
8.75
9.9

Y160M2-2 15

B4

2000

B2

140×60

B4

224×42

ST0201×03
8 C 4704 612
714
816
918
1020
1122
1224
33100
33000
32800
32600
32400
32000
31700
9.4
10.4
11.3
12.3
12.9
15.9
18
Y180M1-2 22

B5

2000

B2

140×60

B5

224×48

ST0201×03
Attention: Please confirm and indicate the fan number, air volume, speed, pressure, outlet angle, rotation direction, and motor model specifications when placing an order. If there are special requirements, please specify them.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!