An air-cooled chiller uses an evaporator to exchange heat between water and refrigerant, and then transfers the heat to a finned condenser through the action of a compressorCooling fanThe air-cooled chiller does not require a cooling tower and can be used simply by connecting a water pipe, as it dissipates into the outside air! The unit has the following characteristics:
Compressor high and low pressure protection, internal overheating protection
Low water level alarm device, low water temperature anti icing alarm
Adopting imported compressors from Europe, America, and Japan
The welding interface of the refrigeration system adopts oxygen free welding method to reduce oxides and achieve a smooth surface
The throttling components are made by Danfoss from Denmark and Eco from the United States
The water tank is made of SUS304 stainless steel to prevent corrosion and water leakage
Adopting stainless steel plate, coil, shell and tube, and finned high-efficiency heat exchangers
RS485 communication function for automated management
The electrical appliance adopts OMRON.FUJI.TE.LGMOELLER.SCHNEIDER
Control method: Imported microcomputer or PLC control is adopted
Complete safety protection, fault display, no need for professional personnel for repair and maintenance
Efficient evaporators and condensers can save over 30% of energy
AC-08 and above use two sets of compressor heads, which can be used separately or together
Technical parameter table of air-cooled industrial chiller (I)
Parameter Model | AC-1/2A | AC-01A | AC-02A | AC-03A | AC-04A | AC-05A | AC-06A | AC-08AD | ||
Refrigeration capacity | KW50HZ | 1.53 | 2.94 | 5.67 | 8.39 | 10.9 | 13.95 | 16.9 | 21.8 | |
Cooling Capacity | Kcal/h 50HZ | 1316 | 2528 | 4872 | 7216 | 9374 | 11990 | 14530 | 18748 | |
Total input power | KW | 0.68 | 1.31 | 2.6 | 3.6 | 4.5 | 5.5 | 6.6 | 8.6 | |
Maximum operating current Maximum Running Current |
A | 4.1 | 8 | 15.8 | 8.8 | 10.9 | 13.4 | 16.20.9 | 31.8 | |
Power Supply | 1N-220 50HZ 3N-380V 50HZ | |||||||||
Refrigeration capacity Refrigerant |
Name | R22 | ||||||||
Charge quantity | Kg | 0.6 | 0.8 | 1.8 | 2.7 | 3.5 | 4.3 | 5 | 3.5×2 | |
Control method Control Type |
Capillary Tube | |||||||||
compressor Compressor |
Type Type | Hermetic Rotary Fully Enclosed Spiral or Piston Hermetic Scroll or Piston | ||||||||
Power Motor | KW | 0.55 | 0.75 | 1.5 | 2.25 | 3 | 3.75 | 4.5 | 3×2 | |
Cooling Air Flow | m³/ | 800 | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 | 8000 | |
Frozen water Chilled Water |
Water volume Row | m³/h | 0.26 | 0.51 | 0.97 | 1.44 | 1.87 | 2.4 | 2.91 | 3.75 |
Water tank | m³ | 0.022 | 0.028 | 0.038 | 0.06 | 0.06 | 0.07 | 0.11 | 0.11 | |
Inlet and outlet pipe diameter In/Out Pipe Size |
G1/2" | G1/2" | G3/4" | G3/4" | G3/4" | GV" | G1" | G1"-1/2" | ||
water pump Water Pump |
Power Motor | KW | 0.375 | 0.375 | 0.375 | 0.375 | 0.375 | 0.75 | 0.75 | 0.75 |
Pressure | Kpa | 180 | 180 | 250 | 242 | 242 | 290 | 290 | 290 | |
External dimensions Size |
Long Length | MM | 600 | 600 | 820 | 945 | 945 | 1035 | 1200 | 1470 |
Width | MM | 400 | 400 | 510 | 550 | 550 | 610 | 650 | 710 | |
High Height | MM | 940 | 940 | 1090 | 1370 | 1370 | 1385 | 1480 | 1700 | |
Weight | Kg | 45 | 60 | 120 | 130 | 160 | 170 | 250 | 270 | |
remarks: 1. The nominal refrigeration is based on an ice water inlet temperature of 15 ℃, an outlet temperature of 10 ℃, and an ambient temperature of 35 ℃. 2. The catalog specifications are subject to change without prior notice. | ||||||||||
Technical parameter table of air-cooled industrial chiller (II)
Parameter Model | AC-10AD | AC-12A | AC-15AD | AC-20AD | AC-25AD | AC-30AT | AC-40AF | AC-50AF | AC-60AG | ||
Refrigeration capacity | KW50HZ | 28.01 | 33.79 | 44.15 | 59.08 | 71.72 | 87.2 | 113.58 | 135.49 | 181.68 | |
Cooling Capacity | Kcal/h 50HZ | 24089 | 29059 | 37965 | 50805 | 61683 | 74992 | 97675 | 116521 | 156249 | |
Total input power | KW | 11 | 13.3 | 17 | 22.8 | 27.7 | 33.7 | 42.8 | 51.1 | 68.8 | |
Maximum operating current Maximum Running Current |
A | 26.7 | 32.3 | 41.3 | 55.4 | 63.1 | 76.8 | 97.5 | 116.5 | 143.1 | |
Power Supply | 3N-380V 50HZ | ||||||||||
Refrigeration capacity Refrigerant |
Name | R22 | |||||||||
Charge quantity | Kg | 4.3×2 | 5×2 | 6.5×2 | 8.5×2 | 10.5×2 | 8.3×3 | 8.5×4 | 10.5×4 | 8.5×6 | |
Control method Control Type |
Capillary tube Capillary Tube |
External Thermal Expansion Valve | |||||||||
compressor Compressor |
Type Type | Hermetic Scroll or Piston Fully Enclosed | |||||||||
Power Motor | KW | 3.75×2 | 4.5×2 | 5.5×2 | 7.5×2 | 9.4×2 | 7.5×3 | 7.5×4 | 9×4 | 7.5×6 | |
Cooling Air Flow | m³/ | 10000 | 12000 | 15000 | 20000 | 25000 | 30000 | 40000 | 48000 | 66000 | |
Frozen water Chilled Water |
Water volume Row | m³/h | 4.82 | 5.81 | 7.6 | 10.16 | 12.34 | 15 | 19.53 | 23.3 | 30.52 |
Water tank | m³ | 0.188 | 0.188 | 0.285 | 0.285 | 0.405 | 0.405 | 0.61 | 0.61 | 7 | |
Inlet and outlet pipe diameter In/Out Pipe Size |
G2B | G2" | G2" | G2" | G2-1/2" | G2-1/2" | G3" | G3" | G3-1/2" | ||
water pump Water Pump |
Power Motor | KW | 1.5 | 1.5 | 1.5 | 2.2 | 2.2 | 4 | 4 | 4 | 4 |
Pressure | Kpa | 205 | 205 | 205 | 220 | 220 | 250 | 250 | 250 | 250 | |
External dimensions Size |
Long Length | MM | 1478 | 1600 | 1680 | 1955 | 2080 | 2400 | 2250 | 2700 | 3600 |
Width | MM | 710 | 800 | 890 | 940 | 1000 | 1100 | 1550 | 1620 | 1800 | |
High Height | MM | 1545 | 1710 | 1710 | 1960 | 1950 | 1950 | 1820 | 1950 | 1900 | |
Weight | Kg | 350 | 370 | 520 | 590 | 790 | 880 | 1100 | 1280 | 1420 | |
remarks: 1. The nominal refrigeration is based on an ice water inlet temperature of 15 ℃, an outlet temperature of 10 ℃, and an ambient temperature of 35 ℃. 2. The catalog specifications are subject to change without prior notice. | |||||||||||