DIS-1D type
--Can be used as a power source for communication, car cigarette sockets, and DC batteries - portable design - can be used for heating and digestion i
Product details

-->Can be used as a power source for communication, car cigarette lighting sockets, and DC batteries
-->Portable design
-->Can be used for outdoor and on-site heating and digestion



Working principle

This instrument can achieve chemical analysis and digestion of COD, total phosphorus, total nitrogen, and total chromium in various water samples such as surface water, industrial wastewater, and domestic sewage that require heating processes. Four reaction tubes with a diameter of 16mm can be placed simultaneously, and the temperature can be automatically controlled according to the set digestion temperature and time.

Technical Parameter

1】 Dissolving temperature:Room temperature~170 ℃, automatic constant temperature control
2】 Temperature control accuracy:±1.0℃
3】 Dissolving time:1~999min
4】 Quantity of single digestion samples:4 of them
5】 Power supply:AC220V, DC12V
6】 Power consumption:80W
7】 External dimensions:80mm ×110 mm ×55mm
8】 Weight:About 2Kg



Product Features


1】 The heating rate is fast, and it only takes 15 minutes to reach the set temperature.

2】 High temperature control accuracy.

3】 With multi-point error free calibration, zero error measurement of the set point is achieved, completely eliminating the errors caused by the nonlinearity of temperature sensors in common digesters on the market.

4】 Effective insulation measures have been adopted to reduce energy consumption.

5】 Equipped with timed reminders.

6】 The instrument has a secondary protection function. When the temperature of the digestion instrument exceeds 185 degrees, the instrument will cut off the power by itself to ensure the safety of the digestion process.

7】 The standard digestion tube is made of imported glass and has the characteristic of not bursting during rapid cooling and heating.

Online inquiry