VIP member
Fiberglass composite salt spray test chamber
Product use: The fiberglass composite salt spray test chamber is used to assess the ability of materials and their protective layers to resist salt sp
Product details
Equipment model | Studio size (D * W * H) mm | Dimensions (D * W * H) mm | |
LRHS-108-RFHY | 450×600×400 | According to the three views of the contract | |
LRHS-270-RFHY | 600×900×500 | ||
LRHS-412-RFHY | 750×1100×500 | ||
LRHS-663-RFHY | 850×1300×600 | ||
LRHS-816-RFHY | 850×1600×600 | ||
LRHS-1080-RFHY | 900×2000×600 |
---|
Technical Parameter
Sales Hotline: 021-608 99999
sexually ability finger treetop |
temperature range | RT+5℃~80℃ | |||||
Humidity range | 30%~98% RH | ||||||
Saturation bucket temperature | RT+10℃~70℃ | ||||||
temperature uniformity | ≤2℃ | ||||||
temperature fluctuation | ±0.5℃ | ||||||
Salt spray deposition amount | 1-2ml/80 cm ². h (16 hour average) | ||||||
Compressed air pressure | 2.00±0.01(kg/cm²) | ||||||
---|---|---|---|---|---|---|---|
spray mode | Continuous/Periodic Optional | ||||||
Sample holder angle | Can meet 15 ° and 30 ° tilt tests | ||||||
test method | NSS test AASS test CASS test | ||||||
send use material material |
Cabinet material | Fiberglass material | |||||
Box cover material | Fiberglass material | ||||||
Air saturated bucket | High quality and premium stainless steel SUS304 | ||||||
Compressed air pipe material | High quality rubber tubing | ||||||
Other pipelines | Thickened fluorosilicone rubber tube | ||||||
pit the heart join in marriage place |
temperature controller | High quality "Youyi Control" brand temperature and humidity instrument | |||||
Dehumidification and cooling | Single machine or double machine cascade refrigeration | ||||||
compressor | Taikang, France | ||||||
temperature sensor | PT100 platinum resistance thermometer | ||||||
Heating pipe | Titanium alloy heating tube | ||||||
Circuit breaker | Schneider miniature circuit breaker (prevents control circuit short circuit) | ||||||
Standard configuration | V-shaped sample holder, round rod, nozzle, funnel, measuring cylinder, mist tube | ||||||
Safety protection | Underphase/reverse phase of the whole machine, equipment timing, rapid fog removal indication, test completion Over temperature, low water level protection, leakage, short circuit, compressor overpressure overload |
||||||
supply voltage | AC380V±10% 50Hz | ||||||
Power | 8.5kW/10.0kW/12.0kW/13.5kW/15.0kW/17.5kW | ||||||
send use ring area |
Temperature: | 5 ℃ to+35 ℃ (average temperature within 24 hours ≤ 28 ℃) | |||||
Relative humidity: | ≤85%RH | ||||||
Note: 1. The above data were measured under good ventilation conditions at an ambient temperature of 25 ℃ 2. We can customize non-standard laboratories according to specific user requirements 3. This technical information is subject to change without prior notice |
Online inquiry