GC126Introduction to the Application of Gas Chromatography:

GC126Gas chromatography is suitable for the specific needs of various laboratories,GC126The system is a gas chromatograph designed for users in various fields both domestically and internationally, providing accurate and reliable chromatographic methods for petroleum, chemical, food safety, and environmental protection.
GC126Gas chromatograph is a product that absorbs the essence of gas chromatograph technology of Shanghai Precision Scientific Instrument Co., Ltd. (formerly Shanghai Analytical Instrument Factory) in recent decades and the advanced technology of gas chromatograph at home and abroad. Newly designedGC126Gas chromatograph, easy to operate and use, provides users with high-quality products.
Simple, intuitive, and user-friendly interface
You can complete:
Setting various parameters of the instrument, such as column box, detector, sampler, etc; Call analysis and storage methods; Start analyzing; Real time browsing of chromatograms, column temperature curves, and real-time status of various parameters; Powerful features supporting data processing
C126System design, convenient and flexible operation experience
Users can use the operation accurately,3.8Chinese large screen LCD display and scrolling menu display, with easy keyboard control.
High performance column boxes, injectors, and detectors
Equipped with six independent temperature control zones: detector, sampler, and auxiliary temperature control zone
The temperature control system with fast heating and cooling capabilities ensures precise temperature control of the column box, ensuring efficient analysis
The dual injection, dual detection, and dual gas path system mechanism can effectively suppress baseline drift in real-time, making it suitable for program-controlled temperature analysis
Suitable for all large-diameter and capillary columns for flow separation/No diversion injection port, packed column inlet Sample mouth
Flame ionization detector(FIDHigh sensitivity and wide dynamic response make the analysis results more accurate
Thermal conductivity detector(TCDHas high sensitivity and low noise
Electron capture detector(ECDZui is sensitive and more reliable, used for analyzing insecticides, halogenated organic compounds, and chlorine containing solvents
Nitrogen and phosphorus detector(NPDSelective sensitive detector for analysis of organic nitrogen and organic phosphorus pesticide residues in food and environment
A user-friendly workstation with a user-friendly interface
A workstation designed for users. The user interface is simple and practical, and the high-speed data acquisition system of * accelerates data collection, making it easier to enter the working state and thus improving work efficiency.
After sales service and
GC126The design is very reliable, but when you need it, Shanghai Jingke's support agencies across the country will conveniently provide you with services in this industry. You can choose from a wide range of service options, including industry-specific support packages, support, and various individual services.

GC126Technical parameters of gas chromatograph:

column oven
Temperature range: room temperature plus5~ 400
Control accuracy:±0.1
Program heating up:6steps/7platform
Maximum heating rate:60/min
Compensation for loss of dual channel chromatography column
injector
Zui can load up to three injectors(2A filling column injection,1Capillary column injection) or2A capillary column sampler.
Injector unit: with independent splitter/Non split injector system and packed column injector system
detector
Zui can load up to three detectors.
Hydrogen flame ion detector(μ-FID): Temperature range: room temperature plus7400
Detection limit:≤4×10-12g/sSample:C16
Micro thermal conductivity detector(μ-TCD:Temperature range: room temperature plus7400
Sensitivity:≥3000mV.mlmg
Electron capture detector(ECD:Temperature range: room temperature plus7350
Radioactive Source:63Ni 10~12mci
Zui small inspection measurement:0.05pg/sSample:r666
Flame photometric detector(FPD:Temperature range: room temperature plus7400
Detection limit:≤3×10-12 g/sP≤3×10-11g/sS
Nitrogen and phosphorus detector(NPD:Temperature range: room temperature plus7400
Detection limit:≤5pgsN≤0.5pgsP