Hana portable conductivity meter HI98192
Hana portable conductivity meter HI98192: Conductivity [EC]: 0.001 to 999.9 amp; amp; #181; S/cm、1.000 to 1000.0 mS/cm, Total Solid Solubility (TDS):
Product details

Hana portable conductivity meter HI98192Introduction:

Conductivity [EC]: 0.001 to 999.9 µ S/cm, 1.000 to 1000.0 mS/cm, Total Solid Solubility [TDS]: 0.00 to 999.9 mg/L (ppm) ppm, 1.000 to 400.0 g/L (ppt); Electrical resistivity: 1.0 to 100.0 MOhms ● cm

Actual salinity: 0.00 to 42.00 PSU, seawater salinity: 0.00 to 80.00 ppt (g/L), salinity: 0.0 to 400.0% NaCl; Temperature: -20.0 to 120.0 ° C, -4.0 to 248.0 ° F

High precision professional EC TDS NaCI - ° C/º F/K measuring instrument, large LCD display screen, conductivity EC resistivity total dissolved solids TDS actual salinity (PSU) seawater salinity salinity (NaCl%) temperature and other conventional important water quality indicators can be quickly and accurately measured, automatically identifying the range and unit conversion; New appearance design, on-screen calibration operation steps prompts, GLP function, quick query of relevant data, USP (645) compliant with international pharmacopoeia measurement standards, automatic identification calibration and user-defined calibration, automatic endpoint locking function, USB data interface, large capacity data storage, and excellent data management.

Hana portable conductivity meter HI98192Parameters:

TECHNICAL INDEX

HI98192

Conductivity [EC] measuring range

0.000 to 9.999 µ S/cm, 10.00 to 99.99 µ S/cm, 100.0 to 999.9 µ S/cm, 1.000 to 9.999 mS/cm
10.00 to 99.99 mS/cm, 100.0 to 1000.0 mS/cm [actual/absolute conductivity, temperature compensation function turned off]

resolution

0.001 μS/cm、0.01 μS/cm、0.1 μS/cm、0.001 mS/cm、0.01 mS/cm、0.1 mS/cm

measurement accuracy

± 1% (± 0.01 µ S/cm or 1 word)

Conductivity constant

Four ring conductive electrode mode, conductivity constant range: 0.010 to 10.000

Calibration Mode

Five point automatic recognition calibration, built-in standard calibration points: 0, 84, 1413 µ S/cm, 5.00, 12.88, 80.0, 118.8 mS/cm

temperature compensation

NoTC、 Linear -20.0 to 120.0 ° C (-4.0 to 248.0 ° F), non-linear 0 to 36 ° C (32 to 98.6 ° F), ISO/DIS 7888 standard

reference temperature

15 ° C, 20 ° C, and 25 ° C; temperature coefficient: 0.00 to 10.00%/° C

Others

Up to 10 independent accounts can be set up, in compliance with USP (645) international pharmacopoeia measurement standards

TDS
【TDS】

measuring range

0.000 to 9.999ppm、10.00 to 99.99ppm、100.0 to 999.9 ppm(mg/L)、1.000 to 9.999ppt
10.00 to 99.99 ppt (g/L), 100.0 to 400.0 ppt (actual/absolute TDS, with temperature compensation turned off), TDS conversion factor: 1.00

resolution

0.001 ppm; 、 0.01 ppm、0.1 ppm、0.001 ppt、0.01 ppt、0.1 ppt

measurement accuracy

± 1% (± 0.05 mg/L or 1 word), whichever is greater

TDS conversion factor

0.40 to 1.00

resistivity measuring range

1.0 to 99.9 Ω• cm, 100 to 999 Ω• cm, 1.0 to 9.99 K Ω• cm, 10.0 to 99.9 K Ω• cm, 100 to 999 K Ω• cm
1.00 to 9.99 M Ω• cm, 10.0 to 100.0 M Ω• cm (actual/absolute resistivity, temperature compensation function turned off)

resolution

0.1 Ω• cm, 1 Ω• cm, 0.01 k Ω• cm, 0.1 k Ω• cm, 1 k Ω• cm, 0.01 M Ω• cm, 0.1 M Ω• cm

measurement accuracy

± 1% (± 10.0 Ohms or 1 word), whichever is greater

salinity

measuring range

Actual salinity: 0.00 to 42.00 PSU seawater salinity: 0.00 to 80.00 ppt (g/L) salinity: 0.0 to 400.0% NaCl

Resolution accuracy

Salinity: 0.1% actual salinity, seawater salinity: 0.01pppt (g/L); Accuracy: Reading ± 1%
Calibration Mode

Single point calibration (recommended HI7037 salinity 100% calibration solution), after conductivity calibration is completed, there is no need to perform salinity calibration again

temperature measuring range

-20.0 to 120 ° C, -4.0 to 248.0 ° F

Other indicators

Resolution: 0.1 ° C, 0.1 ° F, 0.1K; Accuracy: ± 0.2 ° C, ± 0.4 ° F, ± 0.2K [Ignoring probe error]
Calibration mode: single point or two-point calibration

other

Measurement mode

Automatic range, automatic range, locked and fixed range

electrode probe

HI763133 custom built-in temperature sensor with four ring EC-TDS electrodes, DIN interface, 1.5 meters long

GLP function

Refer to relevant information such as conductivity constant, reference temperature, temperature compensation coefficient, calibration point setting, time, date, etc

Data Storage

400 sets of measurement data storage, with a maximum storage capacity of 1000 measurement data

Storage interval: 5, 10, 30 seconds; 1. 2, 5, 10, 15, 30, 60, 120, 180 minutes

USB Data Interface [Recommended HI92000-15 Data Management Transmission Software and Transmission Cable Set]

Power Mode

4 x 1.5V AA batteries; Set standby time: 5, 10, 30, 60 minutes and non automatic shutdown mode

application environment

0 to 50 ° C (32 to 122 ° F), RH max 100%, waterproof standard: IP67

Dimension

Host size: 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4 "); Host weight: 400 g (14.2 oz.)