Hana portable conductivity meter HI98192Introduction:
Conductivity [EC]: 0.001 to 999.9 µ S/cm, 1.000 to 1000.0 mS/cm, Total Solid Solubility [TDS]: 0.00 to 999.9 mg/L (ppm) ppm, 1.000 to 400.0 g/L (ppt); Electrical resistivity: 1.0 to 100.0 MOhms ● cm
Actual salinity: 0.00 to 42.00 PSU, seawater salinity: 0.00 to 80.00 ppt (g/L), salinity: 0.0 to 400.0% NaCl; Temperature: -20.0 to 120.0 ° C, -4.0 to 248.0 ° F
High precision professional EC TDS NaCI - ° C/º F/K measuring instrument, large LCD display screen, conductivity EC resistivity total dissolved solids TDS actual salinity (PSU) seawater salinity salinity (NaCl%) temperature and other conventional important water quality indicators can be quickly and accurately measured, automatically identifying the range and unit conversion; New appearance design, on-screen calibration operation steps prompts, GLP function, quick query of relevant data, USP (645) compliant with international pharmacopoeia measurement standards, automatic identification calibration and user-defined calibration, automatic endpoint locking function, USB data interface, large capacity data storage, and excellent data management.
Hana portable conductivity meter HI98192Parameters:
TECHNICAL INDEX | HI98192 | |
Conductivity [EC] | measuring range |
0.000 to 9.999 µ S/cm, 10.00 to 99.99 µ S/cm, 100.0 to 999.9 µ S/cm, 1.000 to 9.999 mS/cm |
resolution |
0.001 μS/cm、0.01 μS/cm、0.1 μS/cm、0.001 mS/cm、0.01 mS/cm、0.1 mS/cm | |
measurement accuracy | ± 1% (± 0.01 µ S/cm or 1 word) | |
Conductivity constant | Four ring conductive electrode mode, conductivity constant range: 0.010 to 10.000 | |
Calibration Mode | Five point automatic recognition calibration, built-in standard calibration points: 0, 84, 1413 µ S/cm, 5.00, 12.88, 80.0, 118.8 mS/cm | |
temperature compensation | NoTC、 Linear -20.0 to 120.0 ° C (-4.0 to 248.0 ° F), non-linear 0 to 36 ° C (32 to 98.6 ° F), ISO/DIS 7888 standard | |
reference temperature | 15 ° C, 20 ° C, and 25 ° C; temperature coefficient: 0.00 to 10.00%/° C | |
Others | Up to 10 independent accounts can be set up, in compliance with USP (645) international pharmacopoeia measurement standards | |
TDS | measuring range |
0.000 to 9.999ppm、10.00 to 99.99ppm、100.0 to 999.9 ppm(mg/L)、1.000 to 9.999ppt |
resolution | 0.001 ppm; 、 0.01 ppm、0.1 ppm、0.001 ppt、0.01 ppt、0.1 ppt | |
measurement accuracy | ± 1% (± 0.05 mg/L or 1 word), whichever is greater | |
TDS conversion factor | 0.40 to 1.00 | |
resistivity | measuring range |
1.0 to 99.9 Ω• cm, 100 to 999 Ω• cm, 1.0 to 9.99 K Ω• cm, 10.0 to 99.9 K Ω• cm, 100 to 999 K Ω• cm |
resolution | 0.1 Ω• cm, 1 Ω• cm, 0.01 k Ω• cm, 0.1 k Ω• cm, 1 k Ω• cm, 0.01 M Ω• cm, 0.1 M Ω• cm | |
measurement accuracy | ± 1% (± 10.0 Ohms or 1 word), whichever is greater | |
salinity | measuring range | Actual salinity: 0.00 to 42.00 PSU seawater salinity: 0.00 to 80.00 ppt (g/L) salinity: 0.0 to 400.0% NaCl |
Resolution accuracy | Salinity: 0.1% actual salinity, seawater salinity: 0.01pppt (g/L); Accuracy: Reading ± 1% | |
Calibration Mode | Single point calibration (recommended HI7037 salinity 100% calibration solution), after conductivity calibration is completed, there is no need to perform salinity calibration again | |
temperature | measuring range | -20.0 to 120 ° C, -4.0 to 248.0 ° F |
Other indicators | Resolution: 0.1 ° C, 0.1 ° F, 0.1K; Accuracy: ± 0.2 ° C, ± 0.4 ° F, ± 0.2K [Ignoring probe error] | |
other | Measurement mode | Automatic range, automatic range, locked and fixed range |
electrode probe | HI763133 custom built-in temperature sensor with four ring EC-TDS electrodes, DIN interface, 1.5 meters long | |
GLP function | Refer to relevant information such as conductivity constant, reference temperature, temperature compensation coefficient, calibration point setting, time, date, etc | |
Data Storage |
400 sets of measurement data storage, with a maximum storage capacity of 1000 measurement data Storage interval: 5, 10, 30 seconds; 1. 2, 5, 10, 15, 30, 60, 120, 180 minutes USB Data Interface [Recommended HI92000-15 Data Management Transmission Software and Transmission Cable Set] | |
Power Mode | 4 x 1.5V AA batteries; Set standby time: 5, 10, 30, 60 minutes and non automatic shutdown mode
| |
application environment | 0 to 50 ° C (32 to 122 ° F), RH max 100%, waterproof standard: IP67 | |
Dimension | Host size: 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4 "); Host weight: 400 g (14.2 oz.)
|