VIP member
High and low temperature drop ball testing machine
The main purpose is to conduct drop ball impact tests on various plastic films and sheets
Product details

Details Description
Main purpose
- Suitable for conducting drop ball impact tests on various plastic films and sheets. This product complies with GB/T9639 "Test Method for Impact Resistance of Plastic Film and Thin Film - Free Dart Method", and also meets the requirements of SO7765 "Determination of Impact Resistance of Plastic Film and Thin Film - Free Dart Method" and ASTMD1709 "Standard Test Method for Resistance of Polyethylene Plastics to Free Dart Impact" for testing equipment.
- This machine places the test product on a test bench in a high and low temperature environment, and freely drops a fixed weight steel ball from the specified drop height onto the product to impact it. Then, the appearance and various performance of the product are checked. It is suitable for impact strength testing of plastic, ceramic, acrylic, glass, lenses, hardware and other products.



model | T-300PF-D | ||
A: 0 ℃~+150 ℃ B: -20 ℃~+150 ℃ C: 40 ℃~+150 ℃ E: -70 ℃~+150 ℃ | |||
chi cun |
Testing room size W × D × H cm | 90×96×55 | |
Dimensions W × D × H cm | 1260×1026×1300 | ||
sexually ability |
temperature range | -Optional range from 40 ℃ to room temperature | |
Temperature deviation | Temperature: ± 1.0 ℃ | ||
Falling distance | 20CM | ||
Steel ball diameter | optional | ||
Landing time | +20℃→﹣20℃≤30min | +20℃→﹣40℃≤40min | |
material material |
material | Outer box: Cold rolled steel plate with rust prevention treatment and spray coating Inner box: SUS ≠ 304 or SUS ≠ 316 stainless steel plate | |
Insulation material | Rigid polyurethane foam (with flame retardant) | ||
controller | Imported TEMI series 7 touch sensitive temperature and humidity meter | ||
Cooling method | Imported Taikang compressor+finned all copper evaporator+air-cooled condenser | ||
Fault Alarm | Compressor overcurrent, overpressure, overheating, water shortage, heating heater without air burning, leakage protection, over temperature protection, under phase | ||
Select accessories | Cold light plate, fixture bracket, infrared aiming probe |
Online inquiry