Yongjia County Marine Water Pump Factory
Home>Products>ISW, ISWR, ISWH horizontal single-stage single suction pipeline pump
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13676799385
  • Address
    No. 8 Linpu Road, Zhangbao Industrial Zone, Oubei Town, Yongjia County, Zhejiang Province
Contact Now
ISW, ISWR, ISWH horizontal single-stage single suction pipeline pump
The ISW, ISWR, and ISWH horizontal single-stage single suction pipeline pump systems are optimized using hydraulic models based on the performance par
Product details

Model Meaning
ISW、ISWR、ISWH卧式单级单吸管道泵型号意义

Product Introduction
The ISW, ISWR, and ISWH horizontal single-stage single suction pipeline pump systems are optimized using hydraulic models based on the performance parameters of IS and IR centrifugal pumps, following the ISO2858 standard. It is an ideal new generation of high-efficiency and energy-saving horizontal pump product.

Product Features
1. Smooth operation: The absolute concentricity of the pump shaft and excellent dynamic and static balance of the impeller ensure smooth operation without any vibration.
2. Drip proof: Hard alloy seals made of different materials ensure that there is no leakage during the transportation of different media.
3. Low noise: The water pump under two low-noise bearings runs smoothly, with almost no noise except for weak motor noise.
4. Low failure rate: The structure is simple and reasonable, and high-quality matching is used for key parts, greatly improving the fault free working time of the whole machine.
5. Easy to maintain: replace seals and bearings, simple and convenient.
6. More land saving: The exit can be arranged in three directions: left, right, and up, which is convenient for pipeline layout and installation, saving space.
7. ISW horizontal pipeline centrifugal pump is used for conveying clean water and other liquids with physical and chemical properties similar to clean water. It is suitable for industrial and urban water supply, high-rise building pressurized water supply, garden sprinkler irrigation, fire protection pressurization, long-distance transportation, HVAC refrigeration cycle, bathroom and other cold and warm water circulation pressurization and equipment matching. The operating temperature T ≤ 80 ℃.
8. The ISWR horizontal hot water pipeline centrifugal pump is widely used in metallurgy, chemical industry, textile, papermaking, as well as hotels, restaurants, and other boiler hot water pressurized circulation transportation and urban heating systems. The ISWR type uses a temperature T ≤ 120 ℃.
9. ISWH horizontal chemical pump is used for conveying liquids that do not contain solid particles, are corrosive, and have a viscosity similar to water. It is suitable for industries such as petroleum, chemical, metallurgical, power, papermaking, food and pharmaceuticals, and synthetic fibers. The operating temperature ranges from -20 ℃ to+120 ℃.
10. ISWB horizontal pipeline oil pump is used to transport oil products such as gasoline, kerosene, diesel, or flammable and late explosive liquids. The temperature of the transported medium is -20 ℃ to+120 ℃.

application
1. The ISW pump is suitable for industrial and urban water supply and drainage, high-rise building pressurized water supply, garden sprinkler irrigation, fire boosting, long-distance water supply, HVAC refrigeration cycle, bathroom warm water cycle boosting, as well as supporting various water supply equipment and boilers. Used for conveying clean water or other liquids with physical or chemical properties similar to clean water, with a usage temperature not exceeding 85 degrees Celsius℃.
2. The ISWR pump is suitable for metallurgy, chemical industry, textile, wood processing, papermaking, as well as restaurants, bathrooms, hotels, boiler hot water boosting circulation, and urban housing heating circulation, with a usage temperature not exceeding 120 ℃.
3. The ISWD pump is suitable for situations where low environmental noise is required, and the operating temperature should not exceed 100 ℃.

Conditions of Use
1. The suction pressure is ≤ 1.0Mpa, or the working pressure of the pump system is ≤ 1.6Mpa, that is, the pump suction inlet pressure+pump head is ≤ 1.6Mpa, and the pump static pressure test pressure is 2.5Mpa. Please specify the system working pressure when ordering. When the working pressure of the pump system is greater than 1.6Mpa, it should be separately stated when ordering, so that the overcurrent components and connecting parts of the pump can be made of cast steel materials during manufacturing.
2. Environmental temperature<40 ℃, relative humidity<95%.
3. The volume content of solid particles in the conveyed medium shall not exceed 0.1% of the unit volume, and the particle size shall be less than 0.2mm
Note: If the medium used is with small particles, please specify when ordering so that wear-resistant mechanical seals can be used.

scope of application
1. The high working pressure of the system is 1.6MPa, which means that the pump suction pressure+pump head is ≤ 1.6MPa (if the working pressure of the pump system is greater than 1.6MPa, it should be separately specified when ordering, so that cast steel can be used in the manufacturing of the pump's overcurrent components and connecting components)
2. The conveying medium is clear water or other liquids with physical and chemical properties similar to clear water.
3. Environmental temperature ≤ 40 ℃, altitude ≤ 1000m, relative humidity ≤ 95%.

Structure diagram

ISW、ISWR、ISWH卧式单级单吸管道泵结构示意图
Serial Number
name
Serial Number
name
1
pump body
6
water deflector
2
impeller
7
plug screw
3
IMPELLER NUT
8
base
4
mechanical seal
9
electrical machinery
5
pump cover

Spectrogram

ISW、ISWR、ISWH卧式单级单吸管道泵型谱图


performance parameter

model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
25-110
25
2.8
4
5.2
0.78
1.11
1.44
16
15
13.5
34
42
41
2900
0.55
2.3
26
25-125
25
2.8
4
5.2
0.78
1.11
1.44
20.6
20
18
28
36
35
2900
0.75
2.3
28
25-125A
25
2.5
3.6
4.6
0.69
1.0
1.28
17
16
14.4
35
2900
0.55
2.3
27
25-160
25
2.8
4
5.2
0.78
1.11
1.44
33
32
30
24
32
33
2900
1.5
2.3
39
25-160A
25
2.6
3.7
4.9
0.12
1.03
1.36
29
28
26
31
2900
1.1
2.3
34
32-100
32
3.5
5
6.5
0.97
0.39
1.8
13.2
12.5
11.3
40
44
42
2900
0.75
2.3
28
32-125
32
3.5
5
6.5
0.97
0.39
1.8
22
20
18
40
44
42
2900
0.75
2.3
28
32-125A
32
3.1
4.5
5.8
0.86
1.25
1.61
17.6
16
14.4
43
2900
0.75
2.3
28
32-160
32
3.5
5
6.5
0.97
0.39
1.8
33.2
32
30.2
48
54
53
2900
1.5
2.0
39
32-160A
32
3.1
4.5
5.8
0.86
1.25
1.61
29
28
26.3
48
54
53
2900
1.1
2.0
39
32-200
32
3.5
5
6.5
0.97
0.39
1.8
50.5
50
48
34
40
42
2900
3
2.0
77
32-200A
32
2.8
4
5.2
0.78
1.11
1.44
44.6
44
42.7
34
40
42
2900
2.2
2.0
74
32-100(I)
32
4.4
6.3
8.3
1.22
1.75
2.32
13.2
12.5
11.3
48
54
53
2900
0.75
2.0
32
32-100(I)A
32
4.4
6.3
8.3
1.22
1.75
2.32
13.2
12.5
11.3
48
54
53
2900
0.75
2.0
32
32-125(I)
32
4.4
6.3
8.3
1.22
1.75
2.32
22
20
18
48
54
53
2900
1.1
2.3
34
32-125(I)A
32
4.4
6.3
8.3
1.22
1.75
2.32
17.6
16
14.4
40
45
41
2900
0.75
2.3
33
32-160(I)
32
4.4
6.3
8.3
1.22
1.75
2.32
33.2
32
30.2
34
40
42
2900
2.2
2.0
47
32-160(I)A
32
4.1
5.9
7.8
1.14
1.64
2.17
29
28
26.3
34
39
39
2900
1.5
2.3
43
32-160(I)B
32
3.8
5.5
7.2
1.06
1.53
2.0
25.5
24
22.5
34
38
37
2900
1.1
2.3
38
32-200(I)
32
4.4
6.3
8.3
1.22
1.75
2.32
50.5
50
48
26
33
35
2900
4
2.0
43
32-200(I)A
32
4.1
5.9
7.8
1.14
1.64
2.17
45
44
42
26
31
30
2900
3
2.3
62
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
40-100
40
4.4
6.3
8.3
1.22
1.75
2.31
13.2
12.5
11.3
48
54
53
2900
0.55
2.3
32
40-100A
40
3.9
5.6
7.4
1.08
1.56
2.06
10.6
10
9
52
2900
0.37
2.3
32
40-125
40
4.4
6.3
8.3
1.22
1.75
2.31
21
20
18
41
46
43
2900
1.1
2.3
34
40-125A
40
3.9
5.6
7.4
1.08
1.56
2.06
17.6
16
14.4
40
45
41
2900
0.75
2.3
33
40-160
40
4.4
6.3
8.3
1.22
1.75
2.31
33
32
30
35
40
40
2900
2.2
2.3
47
40-160A
40
4.1
5.9
7.8
1.14
1.64
2.17
29
28
26.3
34
39
39
2900
1.5
2.3
43
40-160B
40
3.8
5.5
7.2
1.06
1.53
2.0
25.5
24
22.5
34
38
37
2900
1.1
2.3
38
40-200
40
4.4
6.3
8.3
1.22
1.75
2.31
51
50
48
26
33
32
2900
4
2.3
74
40-200A
40
4.1
5.9
7.8
1.14
1.64
2.17
45
44
42
26
31
30
2900
3
2.3
62
40-200B
40
3.7
5.3
7.0
1.03
1.47
1.94
38
36
34.5
29
2900
2.2
2.3
52
40-250
40
4.4
6.3
8.3
1.22
1.75
2.31
82
80
74
24
28
28
2900
7.5
2.3
105
40-250A
40
4.1
5.9
7.8
1.14
1.64
2.17
72
70
65
24
28
27
2900
5.5
2.3
98
40-250B
40
3.8
5.5
7.0
1.06
1.53
1.94
61.5
60
56
23
27
26
2900
4
2.3
77
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
40-100(I)
40
8.8
12.5
16.3
2.44
3.47
4.53
13.2
12.5
11.3
55
62
60
2900
1.1
2.3
34
40-100(I)A
40
8
11
14.5
2.22
3.05
4.03
10.6
10
9
60
2900
0.75
2.3
32
40-125(I)
40
8.8
12.5
16.3
2.44
3.47
4.53
21.2
20
17.8
49
58
57
2900
1.5
2.3
38
40-125(I)A
40
8
11
14.5
2.22
3.05
4.03
17
16
14
57
2900
1.1
2.3
33
40-160(I)
40
8.8
12.5
16.3
2.44
3.47
4.53
33
32
30
45
52
51
2900
3
2.3
56
40-160(I)A
40
8.2
11.7
15.2
2.28
3.25
4.22
29
28
26
44
51
50
2900
2.2
2.3
47
40-160(I)B
40
7.3
10.4
13.5
2.38
2.89
3.75
23
22
20.5
50
2900
1.5
2.3
43
40-200(I)
40
8.8
12.5
16.3
2.44
3.47
4.53
51.2
50
48
38
46
46
2900
5.5
2.3
85
40-200(I)A
40
8.3
11.7
15.3
2.31
3.25
4.25
45.0
44
42
37
45
45
2900
4
2.3
75
40-200(I)B
40
7.5
10.6
13.8
2.08
2.94
3.83
37
36
34
44
2900
3
2.3
63
40-250(I)
40
8.8
12.5
16.3
2.44
3.47
4.53
81.2
80
77.5
31
38
40
2900
11
2.3
145
40-250(I)A
40
8.2
11.6
15.2
2.28
3.22
4.22
71.0
70
68
38
2900
7.5
2.3
95
40-250(I)B
40
7.6
10.8
14
2.11
3.0
3.89
61.4
60
58
37
2900
7.5
2.3
94
40-250(I)C
40
7.1
10.0
13.1
1.97
2.78
3.64
53.2
52
50.4
36
2900
5.5
2.3
88
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
50-100
50
8.8
12.5
16.3
2.44
3.47
4.53
13.6
12.5
11.3
55
62
60
2900
1.1
2.3
36
50-100A
50
8
11
14.5
2.22
3.05
4.03
11
10
9
60
2900
0.75
2.3
35
50-125
50
8.8
12.5
16.3
2.44
3.47
4.53
21.5
20
17.8
49
58
57
2900
1.5
2.3
43
50-125A
50
8
11
14.5
2.22
3.05
4.03
17
16
14
57
2900
1.1
2.3
38
50-160
50
8.8
12.5
16.3
2.44
3.47
4.53
33
32
30
45
52
51
2900
3
2.3
59
50-160A
50
8.2
11.7
15.2
2.28
3.25
4.22
29
28
26
44
51
50
2900
2.2
2.3
51
50-160B
50
7.3
10.4
13.5
2.38
2.89
3.75
23
22
20.5
50
2900
1.5
2.3
47
50-200
50
8.8
12.5
16.3
2.44
3.47
4.53
52
50
48
38
46
46
2900
5.5
2.3
101
50-200A
50
8.3
11.7
15.3
2.31
3.25
4.25
45.8
44
42
37
45
45
2900
4
2.3
80
50-200B
50
7.5
10.6
13.8
2.08
2.94
3.83
37
36
34
44
2900
3
2.3
68
50-250
50
8.8
12.5
16.3
2.44
3.47
4.53
82
80
77.5
29
38
40
2900
11
2.3
160
50-250A
50
8.2
11.6
15.2
2.28
3.22
4.22
71.5
70
68
38
2900
7.5
2.3
115
50-250B
50
7.6
10.8
14
2.11
3.0
3.89
61.4
60
58
37
2900
7.5
2.3
114
50-250C
50
7.1
10.0
13.1
1.97
2.78
3.64
53.2
52
50.4
36
2900
5.5
2.3
108
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
50-100(I)
50
17.5
25
32.5
4.86
6.94
9.03
13.7
12.5
10.5
67
69
69
2900
1.5
2.5
41
50-100(I)A
50
15.6
22.3
29
4.3
6.19
8.1
11
10
8.4
65
67
68
2900
1.1
2.5
36
50-125(I)
50
17.5
25
32.5
4.86
6.94
9.03
21.5
20
18
60
68
67
2900
3
2.5
56
50-125(I)A
50
15.6
22.3
29
4.33
6.19
8.1
17
16
13.6
58
66
65
2900
2.2
2.5
48
50-160(I)
50
17.5
25
32.5
4.68
6.94
9.03
34.4
32
27.5
54
63
60
2900
4
2.5
72
50-160(I)A
50
16.4
23.4
30.4
4.56
6.5
8.44
30
28
24
54
62
59
2900
4
2.5
71
50-160(I)B
50
15.0
21.6
28
4.17
6.0
7.78
26
24
20.6
58
2900
3
2.5
59
50-200(I)
50
17.5
25
32.5
4.86
6.94
9.03
52.7
50
45.5
49
58
59
2900
7.5
2.5
108
50-200(I)A
50
16.4
23.5
30.5
4.56
6.53
8.47
46.4
44
40
48
57
58
2900
7.5
2.5
107
50-200(I)B
50
15.2
21.8
28.3
4.22
6.06
7.86
40
38
34.5
55
2900
5.5
2.5
100
50-250(I)
50
17.5
25
32.5
4.86
6.94
9.03
82
80
76.5
39
50
52
2900
15
2.5
175
50-250(I)A
50
16.4
23.4
30.5
4.56
6.5
8.47
71.5
70
67
39
50
52
2900
11
2.5
165
50-250(I)B
50
15
21.6
28
4.17
6.0
7.78
61
60
57.4
38
49
54
2900
11
2.5
165
50-315(I)
50
17.5
25
32.5
4.86
6.94
9.03
128
125
122
30
40
44
2900
30
2.5
310
50-315(I)A
50
16.6
23.7
31
4.61
6.58
8.6
115
113
110
30
40
44
2900
22
2.5
245
50-315(I)B
50
15.7
22.5
29.2
4.36
6.25
8.0
103
101
98
39
2900
18.5
2.5
215
50-315(I)C
50
14.4
20.6
26.8
4.0
5.72
7.44
86
85
83
38
2900
15
2.5
195
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
65-100
65
17.5
25
32.5
4.86
6.94
9.03
13.7
12.5
10.5
67
69
69
2900
1.5
2.5
46
65-100A
65
15.6
22.3
29
4.3
6.19
8.1
11
10
8.4
65
67
68
2900
1.1
2.5
41
65-125
65
17.5
25
32.5
4.86
6.94
9.03
21.5
20
18
60
68
67
2900
3
2.5
58
65-125A
65
15.6
22.3
29
4.33
6.19
8.1
17
16
14.4
58
66
65
2900
2.2
2.5
49
65-160
65
17.5
25
32.5
4.86
6.94
9.03
34.4
32
27.5
54
63
60
2900
4
2.5
75
65-160A
65
16.4
23.4
30.4
4.56
6.5
8.44
30
28
24
54
62
59
2900
4
2.5
75
65-160B
65
15.0
21.6
28
4.17
6.0
7.78
26
24
20.6
58
2900
3
2.5
63
65-200
65
17.5
25
32.5
4.86
6.94
9.03
52.7
50
45.5
49
58
59
2900
7.5
2.5
107
65-200A
65
16.4
23.5
30.5
4.56
6.53
8.47
46.4
44
40
48
57
58
2900
7.5
2.5
107
65-200B
65
15.2
21.8
28.3
4.22
6.06
7.86
40
38
34.5
55
2900
5.5
2.5
100
65-250
65
17.5
25
32.5
4.86
6.94
9.03
82
80
76.5
39
50
52
2900
15
2.5
180
65-250A
65
16.4
23.4
30.5
4.56
6.5
8.47
71.5
70
67
39
50
52
2900
11
2.5
170
65-250B
65
15
21.6
28
4.17
6.0
7.78
61
60
57.4
38
49
54
2900
11
2.5
170
65-315
65
17.5
25
32.5
4.86
6.94
9.03
127
125
122
32
40
44
2900
30
2.5
320
65-315A
65
16.6
23.7
31
4.61
6.58
8.6
115
113
110
32
40
44
2900
22
2.5
255
65-315B
65
15.7
22.5
29.2
4.36
6.25
8.0
103
101
98
39
2900
18.5
2.5
225
65-315C
65
14.4
20.6
26.8
4.0
5.72
7.44
86
85
83
38
2900
15
2.5
205
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
65-100(I)
65
35
50
65
9.72
13.9
18.1
13.8
12.5
10
67
73
70
2900
3
3.0
63
65-100(I)A
65
31.3
44.7
58
8.7
12.4
16.1
11
10
8
66
72
69
2900
2.2
3.0
53
65-125(I)
65
35
50
65
9.72
13.9
18.1
22
20
17
67
72.5
70
2900
5.5
3.0
99
65-125(I)A
65
31.3
44.7
58
8.7
12.5
16.1
17.5
16
13.6
66
71
69
2900
4
3.0
78
65-160(I)
65
35
50
65
9.72
13.9
18.1
35
32
28
63
71
70
2900
7.5
3.0
103
65-160(I)A
65
32.7
46.7
61
9.1
13.0
16.9
30.6
28
24
62
70
69
2900
7.5
3.0
103
65-160(I)B
65
30.3
43.3
56.3
8.4
12.0
15.6
26
24
21
69
2900
5.5
3.0
97
65-200(I)
65
35
50
65
9.72
13.9
18.1
53.5
50
46
55
67
68
2900
15
3.0
176
65-200(I)A
65
32.8
47
61
9.1
13.1
16.9
47
44
40
54
66
67
2900
11
3.0
166
65-200(I)B
65
30.5
43.5
56.6
8.5
12.1
15.7
40.6
38
33.4
65
2900
7.5
3.0
114
65-250(I)
65
35
50
65
9.72
13.9
18.1
83
80
72
52
59
60
2900
22
3.0
235
65-250(I)A
65
32.5
46.7
61
9.0
13.0
16.9
73
70
63
52
59
60
2900
18.5
3.0
205
65-250(I)B
65
30
43.3
56
8.3
12.0
15.6
62
60
54
58
2900
15
3.0
180
65-315(I)
65
35
50
65
9.72
13.9
18.1
128
125
121
44
54
57
2900
37
3.0
350
65-315(I)A
65
32.5
46.5
60.5
9.0
12.9
16.8
112.6
110
106.4
43
54
57
2900
30
3.0
335
65-315(I)B
65
31
44.5
58
8.6
12.4
16.1
102.5
100
98
53
2900
30
3.0
335
65-315(I)C
65
29
41
53.6
8.1
11.4
14.9
87
85
83
51
2900
22
3.0
270
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
80-100
80
35
50
65
9.72
13.9
18.1
13.8
12.5
10
67
73
70
2900
3
3.0
63
80-100A
80
31.3
44.7
58
8.7
12.5
16.1
11
10
8
66
72
69
2900
2.2
3.0
54
80-125
80
35
50
65
9.72
13.9
18.1
22
20
17
67
72.5
70
2900
5.5
3.0
99
80-125A
80
31.3
45
58
8.7
12.5
16.1
17.5
16
13.6
66
71
69
2900
4
3.0
79
80-160
80
35
50
65
9.72
13.9
18.1
35
32
28
63
71
70
2900
7.5
3.0
105
80-160A
80
32.7
46.7
61
9.1
13.0
16.9
30.6
28
24
62
70
69
2900
7.5
3.0
105
80-160B
80
30.3
43.3
56.3
8.4
12.0
15.6
26
24
21
69
2900
5.5
3.0
98
80-200
80
35
50
65
9.72
13.9
18.1
53.5
50
46
55
67
68
2900
15
3.0
175
80-200A
80
32.8
47
61
9.1
13.1
16.9
47
44
40
54
66
67
2900
11
3.0
165
80-200B
80
30.5
43.5
56.6
8.5
12.1
15.7
40.6
38
33.4
65
2900
7.5
3.0
115
80-250
80
35
50
65
9.72
13.9
18.1
83
80
72
52
59
60
2900
22
3.0
240
80-250A
80
32.5
46.7
61
9.0
13.0
16.9
73
70
63
52
59
60
2900
18.5
3.0
210
80-250B
80
30
43.3
56
8.3
12.0
15.6
62
60
54
58
2900
15
3.0
185
80-315
80
35
50
65
9.72
13.9
18.1
128
125
122
43
54
57
2900
37
3.0
355
80-315A
80
32.5
46.5
60.5
9.0
12.9
16.8
112.6
110
107.4
43
54
57
2900
30
3.0
340
80-315B
80
31
44.5
58
8.6
12.4
16.1
102.5
100
98
53
2900
30
3.0
340
80-315C
80
29
41
53.6
8.1
11.4
14.9
98
85
83
51
2900
22
3.0
275
80-350
80
35
50
65
9.72
13.9
18.1
146
150
142
55
66
67
2900
55
3.0
570
80-350A
80
31
44.5
58
8.6
12.4
16.1
138.4
142
134.8
65
2900
45
3.0
470
80-350B
80
29
41
53.6
8.1
11.4
14.9
131.4
135
127.8
63
2900
37
3.0
440
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
80-100(I)
80
70
100
130
19.4
27.8
36.1
13.6
12.5
11
66
76
75
2900
5.5
4.5
108
80-100(I)A
80
62.6
89
116
17.4
24.7
32.2
11
10
8.8
64
74
74
2900
4
4.5
87
80-125(I)
80
70
100
130
19.4
27.8
36.1
23.5
20
14
70
76
65
2900
11
4.5
163
80-125(I)A
80
62.6
89
116
17.4
24.7
32.2
19
16
11
68
74
65
2900
7.5
4.5
113
80-160(I)
80
70
100
130
19.4
27.8
36.1
36.5
32
24
70
76
65
2900
15
4.5
184
80-160(I)A
80
65.4
93.5
121.6
18.2
26.0
33.8
32
28
21
68
74
67
2900
11
4.5
174
80-160(I)B
80
60.6
86.6
112.5
16.8
24.1
31.3
72
24
18
72
2900
11
4.5
174
80-200(I)
80
70
100
130
19.4
27.8
36.1
54
50
42
65
74
73
2900
22
4.0
251
80-200(I)A
80
65.4
93.5
121.6
18.2
26.0
33.8
47.5
44
37
64
73
72
2900
18.5
4.0
220
80-200(I)B
80
61
87
113
16.9
24.2
31.4
41
38
32
71
2900
15
4.0
198
80-250(I)
80
70
100
130
19.4
27.8
36.1
87
80
68
62
69
68
2900
37
4.0
330
80-250(I)A
80
65.4
93.5
121.6
18.2
26.0
33.8
76
70
59.5
61
68
67
2900
30
4.0
315
80-250(I)B
80
61
87
113
16.9
24.2
31.4
65
60
51
66
2900
30
4.0
315
80-315(I)
80
70
100
130
19.4
27.8
36.1
132
125
114
55
66
67
2900
75
4.0
675
80-315(I)A
80
66.5
95
123.6
18.5
26.4
34.3
119
113
103
55
66
67
2900
55
4.0
535
80-315(I)B
80
63
90
117
17.5
25
32.5
106.6
101
92
65
2900
45
4.0
420
80-315(I)C
80
58
82
107
16.1
22.8
29.7
90
85
76
63
2900
37
4.0
366
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
100-100
100
70
100
130
19.4
27.8
36.1
13.6
12.5
11
66
76
75
2900
5.5
4.5
113
100-100A
100
62.6
89
116
17.4
47
32.2
11
10
8.8
64
74
74
2900
4
4.5
91
100-125
100
70
100
130
19.4
27.8
36.1
23.5
20
14
70
76
65
2900
11
4.5
169
100-125A
100
62.6
89
116
17.4
24.7
32.2
19
16
11
68
74
63
2900
7.5
4.5
118
100-160
100
70
100
130
19.4
27.8
36.1
36.5
32
24
70
76
65
2900
15
4.5
191
100-160A
100
65.4
93.5
121.6
18.2
26.0
33.8
32
28
21
68
74
67
2900
11
4.5
181
100-160B
100
60.6
86.6
112.5
16.8
24.1
31.3
27
24
18
72
2900
11
4.5
181
100-200
100
70
100
130
19.4
27.8
36.1
54
50
42
65
74
73
2900
22
4.0
245
100-200A
100
65.4
93.5
121.6
18.2
26.0
33.8
47.5
44
37
64
73
72
2900
18.5
4.0
215
100-200B
100
61
87
113
16.9
24.2
31.4
41
38
32
71
2900
15
4.0
193
100-250
100
70
100
130
19.4
27.8
36.1
37
80
68
62
69
68
2900
37
4.0
345
100-250A
100
65.4
93.5
121.6
18.2
26.0
33.8
76
70
59.5
61
68
67
2900
30
4.0
330
100-250B
100
61
87
113
16.9
24.2
31.4
65
60
51
66
2900
30
4.0
330
100-315
100
70
100
130
19.4
27.8
36.1
132
125
114
55
66
67
2900
75
4.0
689
100-315A
100
66.5
95
123.6
18.5
26.4
34.3
119
113
103
65
66
67
2900
55
4.0
549
100-315B
100
63
90
117
17.5
25
32.5
106.6
101
92
65
2900
45
4.0
439
100-315C
100
58
82
107
16.1
22.8
29.7
90
85
76
63
2900
37
4.0
385
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
100-100(I)
100
96
160
192
26.7
44.4
53.3
14
12.5
10
64
73
70
2900
11
4.5
115
100-125(I)
100
96
160
192
26.7
44.4
53.3
24
20
14
62
74
69
2900
15
4.5
168
100-125(I)A
100
84
140
168
23.3
39
46.7
20
17
12
64
72
68
2900
11
4.5
168
100-160(I)
100
96
160
192
26.7
44.4
53.3
36
32
27
69
79
75
2900
22
5.6
210
100-160(I)A
100
84
140
168
23.3
39
46.7
32
28
23.5
66
76
72
2900
18.5
5.0
210
100-200(I)
100
96
160
192
26.7
44.4
53.3
53
50
45
69
79
78
2900
37
5.2
402
100-200(I)A
100
84
140
168
23.3
39
46.7
48
45
40
64
74
73
2900
30
4.5
395
100-200(I)B
100
60
100
120
16.7
27.8
33.3
43
40
36
72
2900
22
4.5
360
100-250(I)
100
96
160
192
26.7
44.4
53.3
83
80
72
65
77
74
2900
55
4.8
560
100-250(I)A
100
84
140
168
23.3
39
46.7
75
72
65
60
72
69
2900
45
4.5
420
100-250(I)B
100
60
100
120
16.7
27.8
33.3
68
65
58
70
2900
37
4.5
400
100-350
100
60
100
120
16.7
27.8
33.3
153.6
150
142
72
57
74
2900
90
4.0
950
100-350A
100
61
87
113
16.9
24.2
31.4
145.6
142
134
75
2900
75
4.0
830
100-350B
100
58
82
107
16.1
22.8
29.7
138.6
135
127
75
2900
55
4.0
600
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
125-100
125
96
160
192
26.7
44.4
53.3
13
12.5
12
82
2900
11
4.0
180
125-100A
125
86
143
172
23.9
39.7
47.8
10.4
10
9.6
77
2900
7.5
4.0
125
125-125
125
96
160
192
26.7
44.4
53.3
22.6
20
17
80
2900
15
4.0
220
125-125A
125
86
143
172
23.9
39.7
47.8
18
16
13.6
77
2900
11
4.0
210
125-160
125
96
160
192
26.7
44.4
53.3
36
32
28
78
2900
22
4.0
265
125-160A
125
90
150
180
25
41.7
50
31.5
28
24.5
76
2900
18.5
4.0
230
125-160B
125
83
138
166
21.7
38.3
46.1
27
24
21
73
2900
15
4.0
215
125-200
125
96
160
192
26.7
44.4
53.3
55
50
46
77
2900
37
5.5
395
125-200A
125
90
150
180
25
41.7
50
48.4
44
40.5
76
2900
30
5.5
380
125-200B
125
83
138
166
21.7
38.3
46.1
41.3
37.5
34.5
75
2900
22
5.5
320
125-250
125
96
160
192
26.7
44.4
53.3
87
80
73
75
2900
55
5.0
580
125-250A
125
90
150
180
25
41.7
50
76
70
84
74
2900
45
5.5
490
125-250B
125
83
138
166
21.7
38.3
46.1
65
60
55
73
2900
37
5.5
430
125-315
125
96
160
192
26.7
44.7
53.3
133
125
119
70
2900
90
5.0
790
125-315A
125
90
150
180
25
41.7
50
117
110
104.6
70
2900
75
5.0
710
125-315B
125
86
143
172
23.9
39.7
47.8
106.4
100
95.2
69
2900
75
5.0
705
125-315C
125
80.5
134
161
22.4
37.2
44.7
96
88
86
67
2900
55
5.0
585
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg
150-125
150
96
160
192
26.7
44.4
53.3
22.6
24
17
66
76
76
2900
11
4.0
210
150-125A
150
90
150
180
25
41.7
50
18
16
13.6
77
2900
7.5
4.0
130
150-160
150
96
160
192
26.7
44.4
53.3
36
32
27
75
2900
22
4.0
270
150-160A
150
90
150
180
25
41.7
50
32
28
23.5
76
2900
18.5
4.0
230
150-160B
150
84
140
168
23.3
39
46.7
27
24
21
73
2900
15
4.0
220
150-200
150
96
160
192
26.7
44.4
53.3
55
50
46
77
2900
37
5.5
395
150-200A
150
90
150
180
25
41.7
50
48.4
44
40.5
76
2900
30
5.5
380
150-200B
150
84
140
168
23.3
39
46.7
41
38
34
75
2900
22
4.0
275
150-250
150
140
200
260
38.9
55.6
72.2
87
80
73
75
2900
75
5.0
630
150-250A
150
131
187
243
36.4
51.9
67.5
76
70
84
74
2900
55
5.5
530
150-250B
150
121
173
225
33.5
48.1
62.5
65
60
55
73
2900
45
5.5
480
150-315
150
140
200
260
38.9
55.6
72.2
133
125
119
70
2900
110
5.0
1080
150-315A
150
131
187
243
36.4
51.9
67.5
117
110
104.6
70
2900
90
5.0
820
150-315B
150
121
173
225
33.5
48.1
62.5
106.4
100
95.2
69
2900
75
5.0
770
150-315C
150
112
160
208
31.3
44.4
57.8
96
88
86
67
2900
55
5.0
640
150-350
150
96
160
192
26.7
44.4
53.3
153.6
150
142.8
80
2900
110
5.5
970
150-350A
150
90
150
180
25
41.7
50
145.6
142
134.8
70
2900
90
5.2
790
150-350B
150
84
140
168
23.3
39
46.7
138.6
135
127.8
65
76
74
2900
75
5.5
705
model
caliber
internet traffic
lift
efficiency
rotational speed
Motor Power
Required cavitation allowance
weight
mm
m3/h
L/S
m
%
r/min
KW
(NPSH)r
Kg

Installation instructions
1. Before installation, carefully check whether there are any hard objects inside the pump body to avoid damaging the impeller and pump body during operation.
2. During installation, pipeline management should not be added to the pump to prevent deformation and affect normal operation.
3. Tighten the anchor bolts to prevent vibration during start-up from affecting the performance of the pump.
4. Install regulating valves on the inlet and outlet pipelines of the pump, and install pressure gauges near the pump outlet to control the pump's operation within rated conditions and ensure its normal use.
5. If a check valve is installed in the discharge pipeline, it should be installed outside the gate valve.
6. The installation methods of pumps are divided into rigid connection installation and flexible connection installation.

Attachment installation method

1Hard connection
2、 Flexible connection
1
Ball valve
2
Imported flexible joint
3
Imported straight pressure tapping pipe
4
Export gate valve
1
Ball valve
2
Imported flexible joint
3
Imported straight pressure tapping pipe
4
Export gate valve
5
Export flexible joint
6
Export straight pipe pressure tapping pipe
7
pump
8
Pump base
5
Export flexible joint
6
Export straight pipe pressure tapping pipe
7
pump
8
Pump base
9
Basic platform
9
Vibration isolator
10
Basic platform

Start and Stop
(1) Preparation before starting
1. Pull and rotate the motor fan blades by hand, and the impeller should have no jamming or grinding phenomenon, and rotate flexibly.
2. Open the inlet valve, open the exhaust valve to fill the entire pump chamber with liquid, and then close the exhaust valve.
3. Manually rotate the pump shaft to allow lubricant to enter the mechanical seal end face.
4. Tap the motor to confirm if the steering is correct.
(2) Start up and operation
1. Fully open the inlet valve and close the outlet pipeline valve.
2. Connect the power supply, gradually open the valve on the discharge pipeline when the pump reaches normal speed, and adjust it to the desired working condition.
3. Pay attention to the instrument readings and check if the shaft seal leakage is normal. The mechanical seal leakage should be ≤ 3 drops/minute. Check if the temperature rise at the motor and bearing is ≤ 70 ℃. If any abnormal situation is found, it should be dealt with in a timely manner
(3) Parking
1. Gradually close the valve of the discharge pipeline and cut off the power supply.
2. Close the inlet valve.
3. If the ambient temperature is below 0 ℃, the liquid inside the pump should be drained to prevent freezing and cracking.
4. If the pump is not in use for a long time, it should be disassembled, cleaned, and kept under management.

maintenance
(1) Maintenance and upkeep during operation
1. The imported pipeline must be filled with liquid, and the pump is prohibited from running for a long time in a cavitation state.
2. Regularly check the motor current value and ensure it does not exceed the rated current of the motor.
3. After long-term operation of the pump, if the noise and vibration of the unit increase due to mechanical wear, it should be stopped for inspection, and vulnerable parts can be replaced if necessary. The overhaul period of the unit is generally one year.
(2) Mechanical seal maintenance and upkeep
1. Mechanical seal lubrication should be clean and free of solid particles.
2. Mechanical seals are strictly prohibited from working under dry grinding conditions.
3. Before starting, the pump (motor) should be turned a few times to avoid sudden starting causing damage to the sealing ring.
4. The allowable deviation for seal leakage is 3 drops/minute, otherwise maintenance should be carried out.

Vulnerable parts (mechanical seals and bearings)

Motor Power
bearing
mechanical seal
0.18KW、0.12KW
201
104-12
0.25KW、0.37KW
202
104-14
0.55KW、0.75KW、1.1KW-2
204
109-18
1.1KW-4、 1.5KW、2.2KW-2
205
109-20
2.2KW-4、3KW
206
109-25
4KW
306
109-25
5.5KW、7.5KW-2、7.5KW-4
308
109-25
11KW、15KW、 18.5KW-2、22KW-2
309
109-35
18.5KW-4、22KW-4
311
109-45
30KW、37KW-2
312
109-45
37KW-4、45KW
313
109-45
55KW、75KW-2、90KW-2
314
109-55

Reference Table for Pipeline Losses

Pipe diameter mm
Flow rate (L/S)
1
2
4
6
8
10
25
3.2
13
38
3.5
14
15
15
20
50
0.8
3.1
13
29
25
30
65
0.8
3.2
7.1
13
20
40
50
75
0.4
1.6
3.3
5.9
9.6
21.6
60
70
100
0.4
0.8
1.3
2.1
6.8
8.6
13
19.
80
90
125
0.2
0.4
0.6
1.3
2.7
4.1
5.9
10.
100
110
150
0.1
0.2
0.5
1.1
1.6
2.3
4.2
6.4
9.4
120
130
175
0.1
0.2
0.5
0.7
1.0
1.9
2.9
4.3
5.8
7.7
9.6
140
160
200
0.1
0.2
0.3
0.5
0.9
1.5
2.1
2.9
3.7
4.7
6.1
7.2
8.5
180
200
250
0.1
0.1
0.2
0.3
0.5
0.7
0.9
1.2
1.5
1.9
2.3
2.8
3.3
3.7
4.9
5.2
300
0.1
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.9
1.1
1.3
1.5
2.0
2.4
3.0

Valve and bent pipe converted to straight pipe length

type
Equivalent to multiple of straight pipe diameter
notes
Fully open gate valve
12
Unopened double
normal bend
25
check valve
100
bottom valve
100
Partial blockage doubles

The flow limit of a certain pipeline is certain

Pipeline diameter
internet traffic
velocity of flow
Pipeline diameter
internet traffic
velocity of flow
mm
L/S
m/s
mm
L/S
m/s
25
1
2.04
125
30.0
2.44
38
2.5
1.69
150
43.0
2.45
50
4.17
2.12
175
60.0
2.49
65
6.67
2.01
200
83.3
2.69
75
10.0
2.26
250
133.3
2.72
100
18.4
2.33
300
192.0
2.71

Fault causes and troubleshooting methods

Fault phenomenon
Possible causes
Troubleshooting
1. The water pump is not producing water
a、 The import and export valves are not open, the inlet and outlet pipelines are blocked, and the impeller of the flow channel is blocked.
b、 The motor is running in the wrong direction and has a slow speed due to phase loss.
c、 The suction pipe is leaking air.
d、 The pump is not filled with liquid and there is air inside the pump chamber.
e、 Insufficient imported water supply, high suction, and leaking bottom valve.
f、 Excessive pipeline resistance and improper pump selection.
a、 Check and remove blockages
b、 Adjust the motor direction and strengthen the motor wiring
c、 Tighten all sealing surfaces and eliminate air
d、 Open the pump cover or open the exhaust valve to exhaust the air
e、 Shutdown inspection and adjustment (this phenomenon is prone to occur when using grid connected water pipes and suction pumps)
f、 Reduce pipeline bends and reselect pumps.
2. Insufficient water pump flow
a、 First, check the cause according to 1.
b、 Pipeline, pump impeller blockage, scale deposition, and insufficient valve opening
c、 Low voltage
d、 Impeller wear
a、 First, press 1. Exclude
b、 Remove the obstruction and readjust the valve opening.
c、 Stabilize voltage.
d、 Replace the impeller.
3. Excessive power
a、 Exceeding the rated flow usage.
b、 The suction distance is too high.
c、 The pump bearings are worn.
a、 Adjust the flow rate and turn down the outlet valve.
b、 reduce
c、 Replace the impeller
4. Noise vibration
a、 The pipeline support is unstable.
b、 Liquid mixed with gas.
c、 Generate cavitation.
d、 The bearing is damaged.
e、 The motor is running under overload and overheating.
a、 Stable pipeline
b、 Increase suction pressure and exhaust
c、 Reduce the vacuum degree
d、 Replace bearings
e、 Press 5 to adjust.
5. Motor overheating
a、 Excessive traffic and overloaded operation.
b、 Rubbing.
c、 The motor bearings are damaged.
d、 Insufficient voltage.
a、 Close the outlet valve.
b、 Check and eliminate.
c、 Replace the bearings.
d、 Stabilize voltage.
6. Water pump leakage
a、 Mechanical seal wear.
b、 The water pump body has sand holes or cracks.
c、 The sealing surface is uneven.
d、 Loosen the installation bolts.
a、 Replace.
b、 Welding repair or replacement.
c、 Repair.
d、 Durable.


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!