Dandong Times Dongke Instrument Co., Ltd
Home>Products>Image Particle Analysis System
Image Particle Analysis System
The HR-T1000 Image Particle Analysis System is a multifunctional particle analysis system developed by our company, which includes image based particl
Product details

One HR-T1000 Introduction:

HR-T1000Image Particle Analysis SystemyesIA multifunctional particle analysis system developed by the company, which includes image based particle size distribution testing and particle morphology analysis. The system includes an optical microscope, digital imaging, and other componentsCCDIt consists of cameras, image processing and analysis software, computers, printers, and other components. It is a product that combines traditional microscopic measurement methods with modern image processing techniques. Its basic workflow is to capture images of the microscope through a dedicated digital camera; Transfer particle images to a computer via USB data transfer method; Through specialized meansParticle Image Analysis SoftwareProcess and analyze images; Output analysis results through displays and printers. This system has the characteristics of intuitiveness, imagery, accuracy, wide testing range, automatic recognition, automatic statistics, and automatic calibration. It can not only be used to observe particle morphology, but also obtain particle size distribution, average aspect ratio, and aspect ratio distribution, adding a new particle size testing method to scientific research and production fields.

II HR-TMain performance indicators of 1000:

serial number

project

performance metrics

serial number

project

performance metrics

1

measurement range

1-3000 microns

6

microscope

domestic

2

repeatability error

≤3 %(Excluding errors caused by sample factors)

7

Scale scale

10 microns

3

Z大放大倍数

4000 times

8

analysis project

Particle size, aspect ratio, roundness distribution

And individual particles and particle groups

4

Z High Resolution

0.1 micron

9

Automatic segmentation speed

≤ 1 second

5

Digital Camera (CCD)

5Million pixels

10

Segmentation success rate

≥93%

III HR-TThe main application areas of 1000 are:

1Abrasive materials:Such as silicon carbide, corundum, diamond, garnet, etc.2. Battery material:Spherical graphite powder, etc.3. Metal powder:Such as spherical aluminum powder, lead tin alloy powder, and other atomized metal powders.4. Non metallic powder:Such as glass beads, polystyrene, etc.5. Needle shaped powder:Such as wollastonite, etc.6. Biological agents:Like a cell7. Food:Like milkmilk powderFlour, etc.8. Other:Such as scientific research, teachingmedicinebloodWait.

4 Test Principle

  • Calibration method:Use a microscope specific standard scale to directly calibrate the size of each pixel, and then measure the particle size in micrometers based on the number of pixels occupied by each particle image area.
  • Testing principle:By counting the number of particles and the number of pixels contained in each particle, the equal circle area and equal sphere volume of each particle are calculated, thereby obtaining the equal circle area diameter, equal sphere volume diameter, and aspect ratio of the particles. For the convenience of calculation, HR-1000The image particle analyzer is measured in units of 100 pixels. The following table shows the particle size values corresponding to 100 pixels under different magnification factors of the objective lens

serial number

Objective magnification

pixel

Particle size (micrometers)

Remarks

1

4 times

100

250

The particle size corresponding to 100 pixels is based on the calibration value.

2

10 times

100

100

3

40 times

100

25

4

100 times

100

10

Five Examples of software functions:

1. Powerful image processing capabilities:(All places)All tasks are completed under this software without the need for other image processing software

2. Intelligent automatic analysis function:(Set SOP analysis sequence, software automatically processes and...)simultaneouslyanalyzeMany cards(Picture)

3. Image analysis:(Can obtain particle size distribution, aspect ratio and distributioncircleShape and distribution, maximum particle size, etc

VISystem features:

1.Calibration:RH-TThe 1000 image particle analysis system can accurately calibrate the actual size of particles through a ruler.

2.Automatic segmentation:It can automatically segment particles that are connected together.

3.Add ruler:You can add a ruler to the image to directly observe the size of particles.

4.Diverse analysis results:Including functions such as opening images, saving images, saving results, querying results, printing granularity results, previewing granularity results, printing images, previewing images, printing aspect ratio results, previewing aspect ratio results, etc.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!