Features and advantages:
◆ The incident light of the LTU500 turbidity meter sensor is generated by a black filament light source with a color temperature between 2200 degrees and 3000 degrees absolute temperature. It is obtained by assembling the black filament light source assembly
Parallel light is guided downwards into the water sample in the sensor, and the light is scattered by suspended particles in the water sample. The scattered light at a 90 degree angle to the incident angle is immersed in the water sample
In the middleSilicon photovoltaic cell receiver receives and measures turbidity by calculating the relationship between 90 degree scattered light and incident beam;
◆ It can be widely used for turbidity monitoring in sewage treatment plants, water treatment plants, water stations, surface water, industrial and other fields.

Main materials |
Body: ABS+SUS316L |
Display Accuracy |
± 2% of the reading or ± 0.015NTU at 0.001-40NTU Take the larger one; 40~100NTU is ± 5% of the reading |
Sealing element: Nitrile rubber |
measuring range |
0.01~100NTU |
|
Cable: PVC |
Operating environment |
0~45℃ |
|
size |
Length 310 * Width 210 * Height 410mm |
velocity of flow |
300ml/min≤x≤700ml/min |
Instrument net quantity |
2.1Kg |
calibration |
Standard solution calibration, water sample calibration, zero point calibration |
Waterproof grade |
IP66/NEMA4 |
Cable Length |
3m standard cable, not recommended for extension |
storage temperature |
-15~65℃ |
pipe fitting |
Injection port: 1/4NPT, discharge port: 1/2NPT |