Product Introduction
MPY-01 Pyroelectric TerahertzDetector operation instructions
The MPY-01 series detector is a compact and highly sensitive pyroelectric terahertz detector that can detect weak electromagnetic radiation signals from ultraviolet to terahertz bands. By replacing different window plates, MPY-01 can be used in different frequency bands and various application scenarios, and is suitable for measuring multiple radiation sources..
The MPY-01 series detector has a wide response band, ranging from ultraviolet to terahertz (UV-IR THz, 10nm-1000um), and has a responsivity of up to 2x10 ^ 5/W. The MPY-01 terahertz detector can be connected to lock-in amplifiers, as well as data acquisition cards or oscilloscopes.
The detector is powered by a single battery, has a stable power supply, and does not require cooling. The detector battery voltage can be monitored through an integrated voltage tester (optional).
MPY-01 has a compact design and high cost-effectiveness, which can save a lot of space and cost for optical experimental optical paths and industrial applications.
MPY-01 High Sensitivity Pyroelectric Terahertz Detector Terahertz Power Meter Technical Parameters
physical characteristics |
|
Detection principle |
PyroelectricPyroelectric |
Detecting materials |
The black layerLiTaO3 |
weight |
80g(including battery) |
Operating temperature |
-20℃-50℃ |
Size(H×B×T) |
64.0mm×48.5mm×20.4mm |
Detector entrance window size |
5.0mm×5.0mm |
Active detection area |
2.0mm×2.0mm |
Electrical characteristics |
|
Power supply |
1×MN21 Battery (12V) |
Power consumption |
Typical values0.3mA |
Measurement time for each battery |
Typical values 30Hour per battery |
output signal |
analog signal |
Output voltage value |
-5V-5V |
Output interface |
BNC |
Measurement characteristics |
|
Voltage responsivity |
20KV/W @633nm,200KV/[email protected];f=20Hz |
Response time(0-100%) |
Typical values0.15s |
Pulse frequency range |
5Hz-1KHz (Optical chopper is required for measuring continuous waves) |
Equivalent power of noiseNEP |
350pW/Hz1/2(@633nm,f=20Hz20,℃ |
) |
Noise density8uV/Hz1/2(rms,f=20Hz, BW-1Hz, 20 |
℃ |
)Detectability rate8Typical values5.7×10cmHz |
1/2 |
/W |
Maximum measured power |
250uW (f=10Hz)2 |
damage threshold |
60 mW/cmSpectral bandwidth |
UV-THzUV to THz |
KBr |
Window panel200nm-30um |
CSi |
Window panel400nm-40um6 |
Teflon |
Window panel |
60um-1000um |
No window panels |
10nm-1000umOther types of window panels can be customized according to requirements
Terahertz detectorGeometric dimensions
Terahertz detector