VIP member
Multiskan Ascent ELISA reader
Good optical performance, with a reading range of 0-6.0 ABS, suitable for measuring 96 well and 384 well plates, fast measurement, and large capacity
Product details
- Product Name: Multiskan Ascent ELISA reader
- Order number: tlyon000390
- Brand Name: Thermo, USA
- Type: Filter ELISA reader
- Filter positions: 8
- Incubator: available
- Printer: External
If you find that the product information is inaccurate, please feel free to correct it; For inquiries about related categories and brand products, please contact us
MULTISKAN ASCENTMicroplate readerThermo Fisher Scientific launches innovative enzyme-linked immunosorbent assay (ELISA) readerMULTISKAN ASCENT, It has excellent photometric measurement performance and can detect 96 well plates and 384 well plates. Advanced software is very easy to apply in both routine testing and scientific research. The compatibility of this machine with automated machinery makes it very suitable for environments with high workloads.Excellent photometric measurement characteristics1. Good optical performance, with a reading range of up to0—6.0ABS2. Suitable for measurement96 well and 384 well plates, fast measurement and large capacity3. Multi purposeASCENR software can be used for research work4. Can integrate with automated machinery5. Easy to use internal software6. The results and measurement plan can be saved on a floppy disk7. Optional temperature controlled incubatorExcellent optical performance, suitable for measurement96 well plate and 384 well plateThermo Fisher Scientific'sMULTISKAN ASCENT provides unique reliability for laboratories around the world. High quality optical systems ensure reliable results with excellent repeatability and accuracy. The maximum absorbance value during measurement can reach 4. This measurement capability reduces the time required to obtain sample results and does not require dilution of the sample.Fast measurement and large capacityMULTISKAN ASCENT can perform fast and accurate measurements in routine testing and scientific applications. It can readThe 384 well plate has exceptional photometric properties that make it suitable for use in environments with high workloads. Measuring a 96 well plate takes at least 14 seconds.Good internal software is very suitable for users' daily useUsers can choose it as their first choice in routine testingMULTISKAN ASCENT's internal software is easy to use, with different operations clearly displayed on the main menu. Due to the question and answer format of the program, the entire setup process is very simple, just follow the prompts to select.The memory of MULTISKAN ASCENT can be stored together100 measurement schemes and 50 measurement results. The internal software includes endpoint method, dual time method, and enzyme-linked immunosorbent assay for measurement, and can perform qualitative and quantitative calculations. The calculation of various types of curves and their conversion and inference between each other make the data processing of the results very flexible.curve type● Linear regression ● Two point method ● Quadratic polynomialFourth degree polynomial● Third degree polynomial ● Curve quantification● Logarithms of four parametersThe internal software has functions such as critical value calculation, calibration conversion, confirmation, quality control, and even dilution calculation, making the internal software more complete.MULTISKAN ASCENT also has a special feature: it intuitively marks the positions of blanks, proofs, controls, and specimens, making it more flexible and convenient to use.High quality enzyme-linked immunosorbent assay (ELISA) platesHigh quality enzyme-linked immunosorbent assay plates from Thermo Fisher ScientificWhen used together, MULTISKAN ASCENT provides the best measurement results in all detection applications. The high-quality surfaces of CLINIPLATE, CLINIPLATE384, and CLMBIPLATE are clean and smooth, fully meeting the optical requirements of high demand assays. The linear absorbance value of the 96 well plate can reach up to 4384, while the absorbance value of the 4 well plate can reach 3.The performance validation test kit is used to verify the accuracy of the enzyme-linked immunosorbent assay (ELISA) readerThe performance verification test box is designed specifically for testing the enzyme-linked immunosorbent assay (ELISA) of the thermoelectric group, with a testing wavelength range of340—750MM, The range of absorbance values is 0.3-4.0, including accurate and precise values.multipurposeASCENT Personal Computer SoftwareEstablished onThe ASCENT software on the WINDOUWS platform is one of the most versatile and flexible software packages, which can be used to open up various measurement programs for different research work.● Clearly set the measurement plan at a glance● With a comprehensive spreadsheet environment, various data processing can be carried out● Multi functional chart curves● Qualitative functionality, including user-defined threshold calculation● Easy and automated machinery andHIS/LIMS system integrationThe steps of the measurement process, such as measurement, oscillation, incubation, and preservation/Calling and pausing, using mouse drag and release techniques is easy to set.Soft drive (optional)In order to save the test results more conveniently or transfer them to a computer for processing,MULTISKAN ASCENT users can choose models with floppy drives and store data results in ASC II format on floppy disks.Incubator (optional)An incubator can be added internally to meet the temperature control requirements of certain experiments, with a maximum temperature of up to50 ℃.Can integrate with automated machinery and adapt to high workload environmentssendAnother characteristic of MULETISKAN ASCENT that is ideal for high workload environments is its ability to be easily integrated with automated devices. For example, this enzyme-linked immunosorbent assay (ELISA) reader can be used in conjunction with the auxiliary plate transport device of a thermoelectric group for fully automated ELISA analysis.effectiveMSCENT software, designed for user convenienceIn the enzyme-linked immunosorbent assay (ELISA) plate shown in the figure, the control, calibration, plate specific blank, calibration concentration, and sample dilution ratio are all listed, making them easy to use.A special electronic spreadsheet environment provides multiple options for data processing and plotting. Curve fitting, qualitative calculation of critical values, dynamic processing tables, blank subtraction, and pre calculation tables all make automatic processing more convenient. Different curve fitting methods, including linear regression, curve quantification, two-point method, and four parameter logarithm, can be utilized and easily converted to each other when needed.TECHNICAL INDEX
optical performance Wavelength range:340NM—850NM Light source: Halogen lamp 6V/10W optical filter 8Position filter wheel, randomly equipped with 4 standard filters The standard filters are 340NM, 405NM, 414NM, 450NM, 492NM, 540NM,620NM,690NM Half bandwidth of filter: 3—6NM Wavelength accuracy: +/-2NM Detector: silicon photodetector Linear (96 well plate): 0—4ABS,+/-1% 0-3ABS,+/-1%, 340NM and 450NM 0—3ABS, +/-1%, continuous board feeding method Linear (384 well plate) 0—3ABS,+/-1% 0—2ABS, +/-1%, continuous board feeding method Reading range: 0—6ABS Resolution:0.001ABS Accuracy: +/-1% or 0.003ABS, with higher accuracy between 0-2ABS; +/-2%(2—3ABS) Accuracy:CV<0.2%(0—3ABS) CV<1.0% (3-4ABS) step mode CV<0.3%(0—2ABS) CV<1.2% (2-3ABS) continuous mode Measurement time: 96perforated plate 384perforated plate Continuous mode9S 20S Self selected incubator temperature range Room temperature+4 ℃ -50 ℃ heating rate <40MIN(20℃-37℃<20MIN)
Online inquiry