Zhongyi Huanke (Beijing) Technology Co., Ltd
Home>Products>Noise detection sound level meter
Noise detection sound level meter
TSI Quest ™ The SE-400 noise detection sound level meter is used to accurately measure the noise level in various environments with significant chang
Product details

Measurement parameters

parameter

SPL, LMax, LMin, LPk (peak), LEQ/LAVG, LE, testing time

weighting

A,C,Z

Corresponding time

Fast and slow

range

110 dBA dynamic measurement range.

Overall range 30-140 dBA (single range)

standard microphone

First level accuracy: microphone QE4936

Second level accuracy: microphone QE7052

Memory

2MB (recording per minute for 34 days)

Maximum peak value

143dBa (sampling peak)

Exchange rate

3、4、5dBA

physical property

size

28.4cm(L) x 7.1cm(W) x 3.3cm(H)

weight

SE-401 type: 367.5g (including preamplifier and microphone)

SE-402 type: 380.5g (including preamplifier and microphone)

SE-401-1S model: 410g (including preamplifier and microphone)

SE-402-1S type: 410g (including preamplifier and microphone)

casing

ABS engineering plastic, IP65 (enclosure meets IP65), excluding microphone and other connecting parts.

Tripod fixation

There is a standard camera tripod hole on the back, with ¼ "-20 thread

Fall protection

2 meters, twice on the front and twice on the back. In case of microphone damage, it does not affect the functionality and stored data.

environment

operate temperature

-10 degrees -50 degrees

humidity

0~90%RH, non-condensing

storage temperature

-20 ° C to 60 ° C

atmospheric pressure

Operation: 80-100kPa Storage: 50-150kPa

Power/Electrical Characteristics

battery

Polymer lithium battery: standard model 2500mAHr/intrinsic safety model 1500mAHr, rechargeable running time: standard model minimum 18 hours (backlight off)/intrinsic safety model 8 hours

BATTERY LIFE

3 years or 500 cycles

Battery charging

The device can be charged using USB. Battery charging time: 8 hours (approximately)

Memory

2MB (recording per minute for 34 days)

standard microphone

First level accuracy: microphone QE4936, second level accuracy: microphone QE7052

Preamplifier

The preamplifier is directly connected to the microphone, with a half inch interface

extension

Remote measurement is possible, with no significant signal loss up to 15 meters (intrinsic safety models are not available)

interface

AC/DC output

3.5mm stereo (top AC, center ring DC, ring GND); Intrinsic safety model not available

I/O interface

RS-232 (intrinsically safe models cannot use I/O interface)

USB

Compliant with USB 2.0 and MINI-USB interfaces

Compliant with standards

IEC61672-1(2002)

Electroacoustic, Sound Level Meter Part 1: Specifications

ANSIS1.43-1997(R2007)

American National Standard: Integral Average Sound Level Specification

ANSIS1.4-1983(R2006)

Specification of Sound Level Meter

CE

self-certified


Noise detection sound level meter SE-400 series

TSI Quest ™ The SE-400 noise detection sound level meter is used to accurately measure the noise level in various environments with significant changes, including environments that require intrinsic safety. These sound level meters can help you more accurately evaluate the noise level in your work environment by calculating the average sound pressure level (LEQ/LAVG) over a certain operating time.

All models can be tested immediately upon startup without the need for settings.


Features and advantages

Ø The red model has intrinsic safety certification

Ø Intuitive interface, no need for training, ready to use out of the box

For the convenience of data download and analysis, users can customize the data recording interval through TSI Quest detection management software (sold separately)

Ø The averaging function simplifies measurements in environments with frequent noise changes

After connecting the optional digital printer *, test data can be printed on-site through the printing function

Choose models that use Class I or Class II microphones according to your application needs

The SE-401 and SE-402-R models are equipped with detachable preamplifiers

Compliant with appropriate industry standards

Practical tools for hearing protection programs; The collected data is accurate and reliable


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!