VIP member
R&S RTO1044 Digital Oscilloscope
Introduction: The RTO series oscilloscope RS RTO1044 from Rohde&Schwarz RS in Germany has excellent signal fidelity, extremely high acquisition rate,
Product details
The R&S RTO1044 oscilloscope series from Rohde&Schwarz in Germany has excellent signal fidelity, extremely high acquisition rate, and the world's first real-time digital triggering system. Its compact structure. The R&S RTO1044 is configured with a 4 GHz bandwidth and supports 4-channel colleague testing. These oscilloscopes have hardware accelerated measurement and analysis capabilities. With fast troubleshooting of signal faults, hardware accelerated analysis functions, and high-precision digital triggering system, the operation method is simpler and faster, achieving convincing measurement accuracy

One million waveforms per second: accurate troubleshooting without guessing.
The blind spot time of R&S RTO oscilloscope is extremely short, and the frequency of its sampled measurement signal is more than 20 times higher. Hardware signal processing saves time and can display results instantly.
Using R&S RTO oscilloscope for high-speed mask testing: within ten seconds,
Capable of collecting, evaluating, and displaying over six million waveforms. The world's first digital trigger achieves maximum accuracy by minimizing trigger jitter.
The digital trigger uses the same digital sampling points as the acquisition system. Unlike analog triggers,
A common time base can ensure the highest measurement accuracy. Unpacking, powering on, measuring:
Never before has an oscilloscope been so convenient.
According to preferences, users can operate using buttons, mice, or touch screens, etc
R&S RTO oscilloscope. After activating multiple graphs, Rohde&Schwarz's intelligent grid
The SmartGrid function can help users to best divide the display area. Convincing measurement accuracy
Typical inherent noise of R&S RTO1024 oscilloscope: standard deviation of histogram measurement
(S-dev) Measurement conditions: 50mV/div, resolution 100ps, no filter. Test Alpha
R&S RTO model
Basic unit bandwidth channel
R&S RTO1044 4 GHz 4
R&S RTO1024 2 GHz 4
R&S RTO1022 2 GHz 2
R&S RTO1014 1 GHz 4
R&S RTO1012 1 GHz 2
R&S RTO1004 600 MHz 4
R&S RTO1002 600 MHz 2
Performance indicators of RTO1044 digital oscilloscope

One million waveforms per second: accurate troubleshooting without guessing.
The blind spot time of R&S RTO oscilloscope is extremely short, and the frequency of its sampled measurement signal is more than 20 times higher. Hardware signal processing saves time and can display results instantly.
Using R&S RTO oscilloscope for high-speed mask testing: within ten seconds,
Capable of collecting, evaluating, and displaying over six million waveforms. The world's first digital trigger achieves maximum accuracy by minimizing trigger jitter.
The digital trigger uses the same digital sampling points as the acquisition system. Unlike analog triggers,
A common time base can ensure the highest measurement accuracy. Unpacking, powering on, measuring:
Never before has an oscilloscope been so convenient.
According to preferences, users can operate using buttons, mice, or touch screens, etc
R&S RTO oscilloscope. After activating multiple graphs, Rohde&Schwarz's intelligent grid
The SmartGrid function can help users to best divide the display area. Convincing measurement accuracy
Typical inherent noise of R&S RTO1024 oscilloscope: standard deviation of histogram measurement
(S-dev) Measurement conditions: 50mV/div, resolution 100ps, no filter. Test Alpha
R&S RTO model
Basic unit bandwidth channel
R&S RTO1044 4 GHz 4
R&S RTO1024 2 GHz 4
R&S RTO1022 2 GHz 2
R&S RTO1014 1 GHz 4
R&S RTO1012 1 GHz 2
R&S RTO1004 600 MHz 4
R&S RTO1002 600 MHz 2
Performance indicators of RTO1044 digital oscilloscope
RTO1044 Digital Oscilloscope Vertical System | ||
Input channel | R&S®RTO1002/R&S®RTO1012/R&S®RTO1022 | 2 |
R&S®RTO1004/R&S®RTO1014/R&S®RTO1024/R&S®RTO1044 | 4 | |
Bandwidth (-3 dB) at | R&S®RTO1002 and R&S®RTO1004 | 600 MHz |
50 Ω | ||
R&S®RTO1012 and R&S®RTO1014 | 1 GHz | |
R&S®RTO1022 and R&S®RTO1024 | 2 GHz | |
R&S®RTO1044 | 4 GHz | |
Rise time (calculated value) | R&S®RTO1002 and R&S®RTO1004 | 583 ps |
R&S®RTO1012 and R&S®RTO1014 | 300 ps | |
R&S®RTO1022 and R&S®RTO1024 | 175 ps | |
R&S®RTO1044 | 100 ps | |
Input impedance | 50 Ω ±1.5 % | |
1 M Ω± 1% with 15 pF (measured) | ||
Input sensitivity | Maximum bandwidth across the entire range | 50 Ω: 1 mV/div to 1 V/Div |
1MΩ: 1 mV/div to 10 V/Div | ||
Effective Bit Number (ENOB) of Analog to Digital Converter | Full range sine, frequency<-3 dB bandwidth | >7 digits (measurement) |
acquisition system | ||
Maximum sampling rate (real-time) | 10 G samples per second per channel | |
R&S®RTO1044 | 10 Gsa/s per channel | |
20 Gsa/s using two channels | ||
Memory depth | Standard configuration, with each channel/1 channel in working state | R&S®RTO: Two channel model: 20/40M sample |
R&S®RTO: Four channel model: 20/80M sample | ||
Maximum Upgrade (R&S)®RTO-B102 option), | R&S®RTO: Two channel model: 100/200M sample | |
Each channel/1 channel is in working state | R&S®RTO: Four channel model: 100/400M sample | |
Maximum collection rate | Continuous collection and display, 10 G samples/s, 1 k samples | 1 million waveforms per second |
Super segmentation mode | <200 ns blind spot time | |
Data Extraction Mode | For any combination of extraction mode and waveform algorithm, each channel can support up to 3 waveforms at most | Sampling, peak detection, high resolution, effective value |
Waveform algorithm | None, envelope, average | |
Interpolation mode | Linear, Sin(x)/x, Sampling and preservation | |
Horizontal system | ||
Time base range | 25 ps/div to 50 s/div | |
Time base accuracy | After supply/calibration | 2.5 ppm |
After supply/calibration (R&S®RTO-B4 option) | 0.02 ppm | |
Channel offset correction | ± 100 ns (real-time offset correction, channel to channel triggering - such as state detection offset correction) | |
Trigger system | ||
Trigger type | Edge, interference, pulse width, under amplitude, window, timeout, interval, slope, data clock, mode, status, serial mode, I2C, SPI, Optional: UART/RS-232, LIN, CAN, FlexRay | |
sensitivity | Definition of Trigger Lag Parameter | Automatic or manual setting range: 0.1 div to 5 div |
Detectable minimum pulse interference signal h | 100 ps | |
R&S®RTO1044 | 50 ps | |
Coupling mode | For the selected channel, RF suppression can be selected within the cutoff frequency range of 100 kHz to 50% of the analog bandwidth | |
Waveform arithmetic operation | ||
Types of Algebraic Operations | Arithmetic operations, logical operations, comparison operations, frequency domain, digital filters | |
Hardware accelerated mathematical calculation function | +, –, *, 1/x, | x|, Seeking guidance, log10, ln, log2Scaling, FIR, FFT amplitude | |
Analysis and measurement functions | ||
Hardware acceleration analysis function | Spectrum, histogram, template testing, cursor | |
Hardware accelerated measurement function | Amplitude measurement, time measurement | |
General data | ||
size | Width x Height x Depth | 427 mm x 249 mm x 204 mm |
(16.81 in x 9.8 in x 8.03 in) | ||
weight | R&S®RTO1024 | 9.6 kg (21.16 lb) |
monitor | 10.4 "LC TFT color touch screen, | |
1024 × 768 pixels (XGA) | ||
connect | 1Gbit/s LAN, 4xUSB 2.0, GPIB (optional), DVI (for external monitor), external trigger |