UAS series UV liquid chromatography separation instrument
scope of application
Chromatography separation experiments in industries such as biochemistry, synthetic chemistry, natural products, drug development, food chemistry, agricultural chemistry, cosmetics, polymers, and petrochemicals. Ion exchange chromatography, affinity chromatography, gel filtration chromatography, hydrophobic interaction chromatography and other methods can be used,Used for rapid separation of target proteins, purification and analysis of complex protein mixtures in specific tissues, cells or organellesThe separation, analysis, and flow detection of enzymes, nucleic acids, nucleotides, peptides (with/without aromatic amino acids), and any other biological/non biological samples with UV absorption are reasonable choices for the purification of biomolecules, characterized by ease of use and economy. Compact design maximizes space savings in cold storage and laboratories.
system configuration
product name |
model |
Configure instruments |
TECHNICAL INDEX |
UV liquid chromatography separation instrument |
UAS-2 |
1. UVD-680-3 UV detector (Built in chromatography workstation) 2. FB-2 constant flow pump 3. BSZ-100 Partial Collector 4. Conversion joint chromatography column and column frame 5. Tool box |
1. Wavelength: 254nm, 280nm-400nm optional (display absorbance value) USB interface, 6 analysis methods for data analysis and calculation 2. Flow rate: 0.6-200ml/min, pressure:>3.5Kg, digital display speed 3. Timing range: 1-9999.99 seconds, collection range: 12mlx100 seconds 4. Chromatography column: φ 10 × 200; φ16×500; φ26×600(mm) 5. One drawer and two open shelves for storing buffer bottles |
UV liquid chromatography separation instrument |
UAS-2A |
1. UVD-680-3 UV detector Or choose one of UVD-680-4 UV detector (with built-in chromatographic workstation) 2. FB-2 constant flow pump 3. BSZ-100 Partial Collector 4. Conversion joint expansion chromatography column and column frame 5. Tool box 6. Six way valve/conversion valve 7. Sample pump 8. TH-500 gradient mixer Composition Simplified: (Protein Purification Chromatography Separation Device) |
1. Wavelength: optional between 254nm, 280nm-400nm (display absorbance value) Wavelength: optional between 200nm and 400nm (display absorbance value) USB interface, 6 analysis methods for data analysis and calculation 2. Flow rate: 0.6-200ml/min, pressure:>3.5Kg, digital display speed 3. Timing range: 1-9999.99 seconds, collection range: 12mlx100 seconds 4. Chromatography column: φ 12 × 200; φ18×300; φ25×600(mm) 5. One drawer and two open shelves for storing buffer bottles 6. Pressure: 20kg/cm, solvent contact: PTFE, 316 stainless steel 7. 0.01-10ml/min continuously adjustable 8. Not resistant to organic matter, provides gradient: 1000ml, gradient shape: can be straight |
Note: 1. PC and printer users can customize locally or purchase on their behalf. 2. Standard wavelength: 254nm, 280nm 3. Simplified protein purification system: equipped with UVD-680-4 UV detector, micro stainless steel sample cell: optical path: 10mm, volume: 8ul 4. Users can configure different models and specifications of partial collectors, gradient mixers, chromatography columns, etc. according to their needs 5. Users can choose according to their needsSample pool optionalFlow Sample Cell: U-shaped(Used for semi preparation, preparation, and production types) optical path:4mm 6mm 8mm Flow rate: 0-300ml/min 0-500ml/min 0-1200ml/min |