Zhoukou General Blower Co., Ltd
Home>Products>W9-19 High Temperature Centrifugal Fan
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    15539485098
  • Address
    No. 37 Zhouxi Road, Chuanhui District, Zhoukou City, Henan Province
Contact Now
W9-19 High Temperature Centrifugal Fan
W9-19 High Temperature Centrifugal Fan
Product details
W9-19 High Temperature Centrifugal FanPurpose:
High temperature centrifugal fan is a professional equipment used to transport high-temperature gases. It is suitable for transporting weakly corrosive and unnatural gases with a dust content and hard particle concentration of no more than 150mg from 250 ℃ to 950 ℃/Generally used for gas discharge in various heating furnaces. The W9-19 high-temperature fan is designed to overcome the phenomenon of insufficient suction force and positive pressure in the furnace caused by the addition of dust removal equipment and waste heat utilization equipment to the boiler, which affects the combustion and normal operation of the boiler. It has the characteristics of high efficiency, low noise, flat performance curve, and wide high-efficiency range. A dust removal device with a dust removal efficiency of not less than 85% must be installed before the induced draft fan to reduce the dust content of the incoming flue gas and improve the service life of the fan. Those with comparable intake conditions and suitable performance can be selected. The maximum temperature shall not exceed 250 ° C.
W9-19 High Temperature Centrifugal Fancharacteristic:
There are currently many industrial boiler series, and the quality of coal used varies greatly. The resistance of the dust collector and economizer used varies, and the required air volume and pressure of the induced draft fan differ greatly. Considering the economy and adaptability of the fan, in addition to the direct coupling transmission of the (D type) coupling, a V-belt (C type) transmission is also used, which can meet the requirements of dust collectors and economizers of the same tonnage boiler configuration type with different speeds for one machine number.
(3) The outlet position of the fan is represented by the angle of the air outlet of the casing. Both "left" and "right" can be made into three angles: 0 °, 90 °, and 180 °.

W9-19 High Temperature Centrifugal FanType:
(1) This fan mechanism is single suction, with four machine numbers: NO.5, 6.3, 8, and 9.
(2) This fan can be made into two types: left rotation or right rotation. Looking at the fan from the transmission part, if the impeller rotates clockwise, it is called right rotation and is represented by "right"; Counter clockwise rotation is called left rotation, represented by "left".
W9-19 High Temperature Centrifugal FanStructure:
The fan is composed of impeller, casing, air inlet, transmission group and other components, and is equipped with regulating door.
(1) Impeller: There are 16 forward curved blades made of 16Mn material. After the impeller is formed, it undergoes static and dynamic balance correction, ensuring smooth and reliable operation.
(2) Shell: Welded into a snail shaped shell with steel plates as a whole. There is a dust cleaning door on the snail plate to facilitate the removal of dust accumulation at the blade and inside the casing, ensuring the balance and aerodynamic performance of the impeller.
(3) Air inlet: Made into a convergent streamlined overall structure, fixed with bolts and front cover plate.
(4) Transmission group: composed of main shaft, bearing box, pulley, etc. The spindle is made of high-quality steel and the bearing housing has an overall structure. Using rolling bearings, the rolling bearings are lubricated with bearing grease.
W9-19 High Temperature Centrifugal FanParameter Table
Machine number rotational speed Full pressure internet traffic Electric motor
r / min Pa m³/h model Power KW
4.5 2900 1838-1815 1174-1995 Y100L-2 3
1744-1584 2269-2817 Y112M-2 4
5 2500 1704-1730 1388-3331 Y100L-2 3
1680-1479 4610-7837 Y112M-2 4
7.1 2900 4824-4769 4610-7837 Y200L1-2 30
463-4296 8912-11064 Y200L2-2 37
8 2600 6002-6075 5912-8671 Y200L2-2 37
5932-5343 10051-14190 Y225M-2 45
9 1450 1593-1616 4695-6886 Y160M-4 11
1576-1409 7981-11267 Y160L-4 15
11.2 1450 3223-3262 9048-13270 Y225S-4 37
3185-2869 15381-21714 Y225M-4 45
12.5 1450 5170-5109 12578-21383 Y280S-4 75
4961-4598 24317-30187 Y280M-4 90
17 1450 8023-8170 63279-78048 Y400-4 400
8117-7704 92806-122344 Y400-4 500
7424-7143 137102-151870 Y450-4 630
18 1450 8995-9159 75116-92647 Y400-4 450
9100-8637 110166-145228 Y450-4 630
8323-8009 162748-180279 Y450-4 800


Attention: Please confirm and indicate the fan number, air volume, speed, pressure, outlet angle, rotation direction, and motor model specifications when placing an order. If there are special requirements, please specify them.
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!