ASTM D5374 Ventilation Aging Test Chamber Product Features:
1) Electronic control APT.line ® Internal preheating technology;
2) Temperature range: ambient temperature+5 ℃ to 300 ℃;
3) MCS controller: 25 stored programs, each program has 100 sections, with a maximum of 500 program segments;
User friendly liquid crystal display screen (LCD)
Easy to read menu guide
Comprehensive electronic chart recorder
Various options for displaying process parameter charts
Real time clock
4) The heating rate can be adjusted through a program editor;
5) Program adjustable air door;
6) High power air turbines have a high air exchange rate (+280%);
7) Rear exhaust pipe with a diameter of 50mm;
8) Fan speed adjustable (0 to 100%);
9) Independent adjustable temperature safety device, level 2 (DIN 12880), with visual alarm;
10) RS422 interface, used for communication software APT-COM@Data control system;
Basic parameters of ventilation aging test chamber M series
model |
M53 |
M115 |
M240 |
M400 |
M720 |
external dimensions(W×H×D) (mm) |
635×780×575 |
835×865×645 |
1035×985×745 |
1235×1185×765 |
1235×1695×865 |
Internal cavity size(W×H×D) (mm) |
400×400×330 |
600×480×410 |
800×600×510 |
1000×800×510 |
1000×1200×600 |
Internal cavity volume(L) |
53 |
115 |
240 |
400 |
720 |
Stainless steel shelf(standard/maximum) |
2 / 5 |
2 / 6 |
2 / 7 |
2 /10 |
2 / 15 |
Load capacity of each shelf/Total load(kg) |
15/40 |
20/50 |
30/70 |
35/90 |
45/120 |
Number of doors |
1 |
1 |
2 |
2 |
2 |
Temperature range: ambient temperature+5 to(°C) |
300 |
300 |
300 |
300 |
300 |
temperature deviation@70°C(± °C) |
0.5 |
0.6 |
0.8 |
0.7 |
0.7 |
temperature deviation@150°C(± °C) |
1.3 |
1.5 |
1.5 |
1.5 |
1.9 |
temperature deviation@250°C(± °C) |
2.8 |
2.8 |
2.8 |
5 |
4.6 |
Temperature fluctuation range(± °C) |
0.3 |
0.3 |
0.3 |
0.3 |
0.3 |
Heating time up to70°C (min) |
5 |
5 |
6 |
6 |
7 |
heating time to150°C (min) |
15 |
16 |
19 |
18 |
21 |
heating time to250°C (min) |
35 |
36 |
42 |
44 |
51/44 |
recovery time(Open the door30Arrived in seconds70°C(min) |
1 |
1 |
1 |
1 |
1 |
recovery time(Open the door30Arrived in seconds150°C) (min) |
3 |
3 |
3 |
3 |
3 |
recovery time(Open the door30Arrived in seconds300°C) (min) |
5 |
5 |
5 |
5 |
5 |
Air exchange rate@150°C(time/hour) |
192 |
96 |
60 |
54 |
36 |
power supply(50/60 Hz) |
230V/1.2KW |
230V/1.6KW |
230V/2.7KW |
400V/3.4KW |
400V/5.0KW |
Net weight(Kg) |
61 |
89 |
131 |
173 |
203 |
Note: For medical device products, please verify the company's business qualifications and medical device product registration certificate first
ASTM D5374 Ventilation Aging Test Chamber:
1) Electronic control APT.line ® Internal preheating technology;
2) Temperature range: ambient temperature+5 ℃ to 300 ℃;