American Industrial Scientific iTrans Fixed Detector
·The iTrans fixed detector adopts an intelligent electronic platform that can provide one or two detection points from a single head, achieving maximu
Product details
  • ·The iTrans fixed detector adopts an intelligent electronic platform that can provide one or two detection points from a single head, achieving maximum flexibility, superior performance, and lower installation costs.

    ·The iTrans fixed detector adopts industry recognized "smart" sensor technology and security functions, including automatic sensor recognition, secure password access, and zero and calibration fault protection (the detector is integrated into a flameproof aluminum or stainless steel casing), which can monitor any gas compound in specific environments.

    ·The transmitter controlled by the iTrans fixed detector microprocessor can operate independently or adopt a multi-point system configuration. After being equipped with onboard relays (optional), the monitor can also operate independently, activate alarms, horns or fans, and shut down the system without the need to return to the central control panel.

    ·Intelligent sensors can be used independently, with digital MODBUS RTU signal output that can be directly connected to PLC or Industrial Scientific controllers. The remote transmission distance of signals can reach up to 500 meters

    ·In places where different gases need to be detected simultaneously, as well as in places where toxic and harmful gases need to be detected remotely, the dual sensor and intelligent sensor remote detection functions can greatly reduce installation and wiring costs and improve detection flexibility.

    ·The devices above the Trans fixed detector are equipped with 4-20mA and MODBUS RTU digital transmission signals. All configurations can use various sensors.

    technical indicators

    Shell: Aluminum or stainless steel (IP66) explosion-proof shell

    Dimensions: 153 mm x 138 mm x 129 mm

    Weight: 3.5g

    Service life (standard temperature): 4-5 years

    Response time: LEL<>

    Concentration display: 4-digit LED digital display

    Fault output:<>

    Supply voltage and power consumption: 24VDC (12-28VDC)<>

    Analog signal: Three wire 4-20mA output (maximum load resistance not exceeding 500 Ω under 12-28VDC)

    Digital signal: RS485 MODBUS RTU communication protocol

    Temperature range: -40~70 ℃ (depending on sensor type)

    Humidity range: 15~95% RH (non condensing)

    China Certification:

    Fire Protection: GB 15322-94, Fire Protection Certificate Number: 0802030004

    Explosion proof: GB 3836 1-2000, GB 3836 2-2000 Mark: Ex dIIC Certificate Number: GYB02585

    计量: GB 12358-90,JJG693-90,JJG915-96,JJG695-90,JJG365-98

    install

    1. Selection of instrument installation location?

    The installation position of the instrument should be selected at potential leakage points or gas accumulation points, and the installation height of the instrument should be determined according to the density of the measured gas.

    The installation position of the instrument should also take into account the speed and direction of air flow, the relative position of potential leakage sources, and ventilation conditions, and be easy to maintain and calibrate.

    Note: The instrument should be directly installed on a heat source or vibration source.

    2. Installation method of the instrument

    For the convenience of users, this instrument has two installation methods to choose from:

    a. Can be used by accessory users, with two installation methods to choose from;

    b. Can be installed on the wall using 4 M8 expansion bolts