American Neutronics MODEL1100BEL-N1 Oxygen Analyzer
The NTRON 1100 electrochemical oxygen analyzer uses a weakly acidic electrolyte inside the sensor. The measurement range ranges from 0-1% to 0- * with
Product details

The electrochemical oxygen analyzer MODEL 1100 uses a weakly acidic electrolyte inside the sensor. The measurement range ranges from 0-1% to 0- * with high-performance microprocessors, making the measurement of oxygen concentration more reliable and stable.

The sensor should use a weak acid electrolyte to expand the application range of oxygen measurement. Can be applied to CO2, CO, H2S, Nox, N2, Ar, H2,
Measurement of oxygen in background gases such as CH4, and the influence of highly corrosive gases such as Cl2, CFC'S, SO2, NH3, HCl on oxygen measurement

Characteristics

● Small size, easy installation

● High brightness * type LED digital display

Electrochemical sensors

● * Non corrosive sensor electrolyte

● Low price

● Sensors installed on panels or remotely transmitted

Can be used for measuring acidic gas backgrounds without any impact, such as CO, CO2, NOx, etc

● Long service life of 5 years

Electrochemical Oxygen Analyzer MODEL 1100 Technical Parameters

sensor

Electrochemical sensors, installed internally or remotely

measurement range

0-1%/0-10%/0-25%/0-50%/0- * Automatic range or fixed range

display

0.75 "(19.05mm) LED digital display, system status LED indicator light: yellow light in case of fault, green light in normal and online measurement. Alarm 1 and 2 alarm indicator lights.

response time

<15 seconds T90

precision

At constant temperature: ± 2% range

When exceeding the operating temperature: ± 5% range

But when using the standard gas calibration of the measured point: ± 1% range

Operating temperature

5-45℃

signal output

RS-232 communication interface, 4-20mA, 0-10VDC

(Or 0-1VDC, 0-5DC)

alarm output

Two alarm relay outputs can be set as three lower limit alarms

Sample gas interface

1/8 '' NPT internal thread

electrical connection

Pluggable electrical connection terminal block

working power supply

5W 115/230VAC 50/60Hz or 12-30VDC

Protection level

Panel: NEMA 4, IP66

Machine box: NEMA1, IP20

quality assurance

Electronic components: 1 year,

Sensor: CAG-21 6 months/CAG250E 2 years

weight

Analyzer: less than 0.9kg