Product Introduction
BMT964AQ-LC is a precision ozone machine for cleaning ozone. The measurement principle uses a UV photometer, which can directly measure the ozone content in clean water or water with constant turbidity without generating bubbles. The average time between failures of instruments, including lamps, exceeds 65000 hours. The average time between failures, excluding lights, is 120000 hours. Mainly used for monitoring ozone in pure water systems or continuously turbid water, pharmaceutical industry, biotechnology industry, food, baby food industry, beverage industry, etc.
BMT964AQ-LCIt is a precision ozone machine for cleaning ozoneThe principle of measurement is usedUV photometer can directly measure the ozone content in clean water or water with constant turbidity without generating bubbles. Cleaning method: extremely low turbidity. Cleaning method: very low deposition on the surface.
The materials in contact with ozone water include stainless steel,PVDF,PFAQuartz andFFPMClean the quartz colorimetric dish window if necessaryBut the operationIt's simple.
By using a true dual beam optical system and an extremely long-lasting mercury lamp, excellent stability of the photometer can be achieved. The average time between failures of instruments, including lamps, exceeds65,000Hour. The average time between failures, excluding lights, is120,000Hour.
BMT964AQ-LCisaSensor, because it doesn't have a display screen. It is designed to pass through4-20 mAperhaps0-10 VSignal lines or isolated onesRS-232Serial connection directly connects to the workstation.
optionaljoin in marriageremote indicationBMT964RDCan be used for installation without a workstation. To use with a remote monitor, it must be orderedBMT964AQ-LC / RDVersion ofBMT964AQ-LC.
The built-in microcontroller allows for remote display or software usageBMT964Link(Provided with the instrument)Windows PCPerform tests on many parameters of the instrumentset up.

-Dual beam UV photometer
-Stainless steel sample tank
-Long life mercury lamp
-High precision, with an error not exceeding0.5%
-Scope from0.5to15g/Nm3(ppmw)
-Cleaning the colorimetric dish window is simple
- Automatic zeroing of electrical contact control
-Error Alert: Insufficient Brightness, Sample Tank Contamination, Out of Range, Error Summary
-Set up functions through computer window software
-High and low limit alarm
-Timer setting automatically resets to zero
- 4-20mAand0-10VIsolated output
- RS-232Interface (bidirectional)
-Optional: Remote display for reading and control
-Monitor ozone in purified water systems or continuously turbid water
-Pharmaceutical industry
-Biotechnology industry
-Food, baby food industry
-Beverage Industry
|
measuring principle |
Dual beam UV photometer(254nm) |
|
MTBF |
The instrument includes a UV lamp65,000hExcluding UV lamps120,000h |
|
Ultraviolet Lamp |
Low pressure mercury lamp, long-life design |
|
concentration range |
0.5,0.75, 2,5,10, fifteeng/Nm3(ppmw), optional unitsg/Nm3andppmw |
|
accuracy |
The maximum sum of errors after zeroing is: the sum of the measured values0.4%+Range of measurement0.1% |
|
Repeatability error |
The measured values0.2% |
|
response time |
0.03s(Analog output),0.3s(Display) |
|
zero-drift |
0.2%/Oh my god(non-cumulativeSex) |
|
Maximum inlet pressure |
10Bar |
|
ambient temperature |
0-50°C(mistakeCondensation) |
|
Contact materials |
SSQuartz,PFA,FFPM,PVDF |
|
Fluid port |
PVDFCompression joint is used for4x6mm(5 / 32''x1 / 4'')PTFEPipe or1/4''swagelok |
|
referral traffic |
standardThe value is0.05to0.1L/min |
|
pressure drop |
use0.1L/minThe speed is about10 m Bar |
|
signal output |
4-20mA(Isolation,activation)0-10V(Isolation) |
|
Concentration alarm |
tall/Low concentration alarm |
|
control in |
Set to zero(24V,18mAIsolation) |
|
control output |
Relay contacts,28V,0.5AIsolationLow light, color cup pollution, high/Low alarm, purge control(Lamp Low,Cuvette Dirty,High Alarm,Low Alarm,Purge Control) |
|
Error report handling |
Error relay:30V,1ASummary of instrument malfunction warnings and errors: low bulb error, bulb off error,Low light bulb warning,Color comparison dish dirty warning, color comparison dish dirty error, over range, over pressure |
|
serial interface |
RS-232, bidirectional,2400-38400Baud |
|
AUTO ZERO |
By blowing the contacts, it can be done |
|
power supply |
100-240VAC,15VAOptional:12-36VDC,15W |
|
size |
360x160x91(Wide)xtallxDeep) |
|
weight |
4kg Clean the water |
BMT964AQ-LCOzone sensor with waterproof and splash proof aluminum casing(IP65,NEMA4X)360x160x91mm(WxHxD), with waterproof coating(RAL5009, sky blue), weighing about4Kilogram. Four installation brackets are provided forSENSORInstall where needed. All electrical connectors are waterproof.
As long as the colorimetric cup of the sensor is kept clean, there is no need to spend weeks or even months zeroing the instrument. But for safety reasons, zero readings should be checked regularly.
BMT964AQ-LCOzone sensor detects ozone in clean water, and the isolated signal output is transmitted through10MegOhmsConnect the resistor to the grounding protection.
otherBMTProduct (for detailed information, please refer to the corresponding data sheet):
- BMT964AQUsed for ultra pure deionized water
- BMT964(Standard version), used for measuring ozone in the air
- BMT932Ozone monitor, used for monitoring in ambient air(1、3and6Channel)
- BMT802X(4g / h)AndBMT803(8g / h)Ozone generator