BT-5000 Constant Current Air Sampler
BT-5000 Constant Current Air Sampler
I. Overview
BT-5000A constant current air sampler is an instrument used to collect gaseous or vapor samples from the atmosphere, suitable for sampling individual toxic substances and dust substances such as metals at designated locations for occupational hazards in the workplace; It is also applicable to the environment and atmosphere,public healthRoutine monitoring and emergency monitoring.
The constant flow air sampler mainly consists of an operating system, an intelligent control system, an air pump, and a flow measurement system. Fully charged once for continuous operation20More than one hour, convenient for sampling work. This instrument has real-time flow rate, sampling volume, sampling time, temperature, atmospheric pressure, and electricity display. It has the advantages of compact structure, small volume, light weight, durability, strong load capacity, stable and accurate flow rate, and low noise.
2、 Application Fields
BT-5000The constant flow air sampler is a disease prevention center,environmental monitoringThe ideal instrument for short-term or long-term air detection and sampling by environmental protection personnel in colleges, universities, research institutions, and testing institutions.
Execution standard:
JJG956-2013air samplerVerification regulations
GBZ/T300-2017Sampling standards for harmful substances in workplace air
GB50325-2010Code for Indoor Environmental Pollution Control of Civil Building Engineering
HJ 194-2017Technical Specification for Manual Monitoring of Environmental Air Quality
3、 Technical parameters
1Flow range:(100~1500ml)/min;
(20-500ml)/min;
(1000ml-5000ml)/minConfigure a pre separator to collect individual dust (flow rate optional)
Choose one of the traffic options
2Constant current mode: electronic constant current (digital constant current; built-in high-precision sensor; instrument can be self calibrated)
The flow rate is not affected by voltage fluctuations and air resistance changes
3Flow error: ≤±5%
4Traffic stability: ≤5%
5Traffic repeatability: ≤2%
6Timing error: ≤±0.1%
7Timing range:1min~99h59min
8Working temperature:-10~50℃
9Relative humidity: ≤95%RH
10Battery life:>20hour
11Load capacity: ≥35000pa
12Timer mode: ① Loop sampling(99Multiple cycles can be used to sample volume or time, set sampling time, pause time, and number of cycles.
② Manual sampling: After setting the sampling flow rate, you can directly sample, start timing, and manually shut down.
③ Timed sampling, set the sampling time, and stop sampling when the time is up.
④ Fixed volume sampling(1000L)Set the sampling volume for sampling.
13Host size:122*60*72mm(Long)*wide*High)
14Operating noise: <60db
15Instrument weight:0.5kg
16Power supply:DC7.4V,220VAC±10%;