Note:For more information on similar products and industry solutions, please consult our online customer service or call our sales hotline at 400-0093-968 to inquire about product prices, models, parameters, and request product information.
Characteristics and Applications:
Sensors adopt cylindrical and column structures according to the magnitude and effect of the load force. It has the characteristics of large range, good structural sealing, stable and reliable performance, and easy installation and use.
External dimensions:
Range
ФA
B
C
D
ФE
ФF
ФG
SR
4-M
L
10~30t
94
130
14
106
42
89
56
40
M10
124
50~100t
129
178
18
148
76
124
82
75
M12
160
150~200t
149
220
24
182
100
144
98
95
M14
180
250~300t
184
260
28
216
120
178
130
130
M16
219
Technical indicators:
Parameters
unit
Technical Parameter
Parameters
unit
Technical Parameter
sensitivity
mV/V
1.0~1.5±0.05
Sensitivity temperature coefficient
≤%F·S/10℃
±0.1
Nonlinear
≤%F·S
±0.3
Working temperature range
℃
-20℃~+80℃
Lag
≤%F·S
±0.3
Input Resistance
Ω
750±20Ω
repeatability
≤%F·S
±0.15
output resistance
Ω
700±5Ω
Creep
≤%F·S/30min
±0.3
Safe Overload
≤%F·S
150%F·S
Zero point output
≤%F·S
±1
insulation resistance
MΩ
≥2000MΩ(50VDC)
zero temperature
≤%F·S/10℃
±0.1
Recommended incentive voltage
V
10V~15V