Regarding the improvement of teachingmicroscopeDesigned for the workflow
The CX23 microscope designed for students is not only sturdy and durable, but also reliable in performance. Due to the following design features, it can be easily carried to the classroom:
Less space occupied
lightweight
Ergonomically designed anti slip handle
Its safety performance design ensures that the eyepiece, observation tube, objective lens, and stage are not easily damaged during transportation or long-term repeated use.

Excellent optical performance
Uniform LED lighting with stable color temperature can display realistic colors for various samples. From an economic perspective, LED lights also have the advantages of a long lifespan of 20000 hours and low power consumption.
The CX23 microscope also has a large field of view (FN) of up to 20, which can provide a wider field of view. Its specially designed flat field achromatic objective lens ensures a flat image throughout the entire field of view.


portable
The CX23 microscope is the lightest in its class of applicationsOlympus microscopeOne of them weighs approximately 5.9 kilograms (13.01 pounds). The anti slip handle and V-shaped handle design allow users to carry the microscope comfortably and safely. The observation tube and eyepiece can be fixed on the microscope to avoid damage or loss during movement.


Observing Comfort
The CX23 microscope is designed for comfortable microscopic observation. Users can easily adjust the pupil distance and eye point height according to their comfort level, and can also adjust the left and right refractive power to give each eye appropriate focus. When in use, the locking pin can fix the observation tube in place.


Comfortable specimen handling
The user oriented design features of CX23 microscope make specimen placement and related settings adjustments easier:
The inward rotating objective lens converter makes stage operation easier, allowing for quick sample replacement and easy addition of lens oil as needed
Long working distance flat field achromatic objective lens provides better gap between thicker samples and glass slides
The coaxial knob that can be easily operated from any side of the microscope allows for quick focus adjustment or coarse adjustment


Avoid damage to the microscope/specimen
In order to avoid damage to the microscope and specimen, CX23 also adopts an anti damage design:
Focusing limit lock can prevent the objective lens from damaging the sample.
The torque release function can prevent excessive force on the coarse focus knob and the stage knob.

easy to store
The following practical functions make the storage of CX23 microscope more convenient:
The storage compartment located on the back of the microscope can be used to store power cables and AC adapters
Built in safety lock hole can be used to connect anti-theft cables


Using digital cameras to improve your training efficiency
Use a digital camera to share the images you see on the CX23 microscope in the classroom or with the audience. The digital camera installed on the CX23 observation tube allows for easy image capture and recording.

Kohler Lighting Fundamentals Training
The CX23 microscope can be equipped with a field of view aperture (CX23-FS). CX23 enables users to use and demonstrate Kohler lighting, providing support for basic training of microscopes.

Antifungal treatment
When used in hot and humid environments, microscopes are susceptible to damage from mold and other fungi. For this reason, the objective lens, eyepiece, and observation tube of the CX23 microscope have undergone antifungal treatment, which helps ensure better usability and superior durability.

Head up display, convenient for collaboration
Easily share and display images in the classroom using a wireless EP50 digital camera that supports LAN. Combining this camera with our CX series student microscope can transform a regular classroom into a digital classroom. For group users, the head up display system can achieve easy viewing. Everyone can see the observed specimen in real time, without the need to take turns viewing through the eyepiece.

| Observation method | bright field | ✓ | |
|---|---|---|---|
| dark field | ✓ | ||
| Illuminator | Transmitted Illuminator | LED Lamp |
|
| focus | Focus mechanism | Stage focusing | ✓ |
| Handle stroke |
|
||
| feature | Rough adjustment limit valve |
||
| Field Diaphragm | Binocular (Option: CX23-FS) | ✓ | |
| Trinocular | ✓ | ||
| Revolving Nosepiece | Manual | Standard (4 positions) | ✓ |
| stage | manual | Mechanical stage with right-hand control knob |
|
| Spotlight lens | manual | Abbe spotlight | NA 1.25/W.D. - (4X – 100X) (built-in) |
| barrel | Standard (FN20) | Binocular tube | ✓ |
| Three eye tube | ✓ | ||
| Tilt angle of the lens barrel |
|
||
| Three lens tube optical path (camera: visible to the naked eye) |
|
||
| Interpupillary distance adjustment |
|
||
| Dimensions (width x depth x height) | Binocular tube: 198 (W) x 398 (D) x 386 (H) mm, Trinocular tube: 198 (W) x 398 (D) x 430 (H) mm | ||
| weight | Approximately 5.9 kg |