Chengdu Column Vacuum Circuit Breaker ZW32-35kv Specification Parameters
overview
The ZW32-40.5 outdoor high-voltage vacuum circuit breaker adopts a uniquely designed integrated solid sealed pole and a highly reliable operating mechanism. This device is mainly used in medium voltage overhead power grids for the purpose of dividing and combining load currents, overload currents, and short-circuit currents.
characteristic
U has extremely high reliability
U is completely maintenance free throughout its entire lifespan
U has high mechanical and electrical lifespan
The whole machine has a small volume, light weight, and is easy to install
Conditions of Use
Surrounding air temperature: -30 ℃ to+60 ℃;
Altitude: not exceeding 3000 meters;
Wind speed not exceeding 34m/s;
External vibrations or ground movements from switchgear and control equipment can be ignored;
Pollution level: Level IV;
Storage temperature: -40 ℃ to+85 ℃.
Product style, physical image
Chengdu Column Vacuum Circuit Breaker ZW32-35kv Specification Parameters
after-sale service:
There is a complete after-sales service system for vacuum circuit breakers from receiving orders to delivering products to customers.
When the product is safely transported to the customer's hands, the customer must carefully inspect it. The specific inspection items are as follows:
1. Check if the packaging is damaged;
2. Check whether the documents, accessories, and spare parts are complete by comparing with the product packing list;
3. Check whether the technical parameters and product qualification certificate on the nameplate of the circuit breaker on the column meet the ordering requirements.
Kind reminder: Before installation after purchase, vacuum circuit breakers must be stored indoors in a dry, ventilated, moisture-proof, shock resistant, and harmful gas resistant environment. When stored for a long time, the environment should be regularly checked to ensure compliance with requirements.
Packing, unpacking, and storage should be carried out in a dry room, and the products and components should be checked for completeness and consistency.
Technical Parameter
Rated voltage KV: 40.5
Rated frequency Hz: 50/60
3 Rated current A: 630/1250/2500
4 rated short-circuit breaking current KA: 20/25/31.5
5 rated short-circuit current breaking times: 30
6 rated peak withstand current KA: 63/80
7 rated short-circuit closing current (peak) KA: 63/80
8 mechanical life cycles: 10000
9 4S short-time withstand current KA: 25/31.5
10 power frequency withstand voltage (1 minute): dry test (phase to phase, ground/fracture) KV: 80 95/95
11 lightning impulse withstand voltage (peak) phase to phase, relative/fracture KV: 185
12 rated operating cycles: on-off -0.1s-on-off -3s on-off -6-son-off -60s on-off -60s restoration
13 institutions control voltage AC/DC220