VIP member
Product details
The power monitoring system in the computer room mainly monitors the use of three-phase power and our backup batteries or UPS to ensure that our computer room can continue to be used in the event of unstable power and power outages, minimizing the losses caused by power outages while also ensuring that our hardware is not damaged by power outages.At present, the power monitoring system in the computer room is mostly integrated into our environmental monitoring system, and few computer rooms will use itThe separate listing of the computer room power monitoring system for monitoring mainly integrates multiple functions of our system, so our computer room environment monitoring system is more powerful in terms of functionality.
The problems that need to be solved in the power monitoring system of the computer room
(1) Fire safety issues.
(2) Water leakage issue.
(3) Temperature issue.
(4) Humidity issue.
(5) Checking various power sources is troublesome.
(6) Personnel access issues.
(7) The issue with air conditioning.
(8) UPS or battery issues.
2. Safety and reliability:
(1) Considering the security and reliability of data center equipment and the services it carries, it is necessary to establish a unified monitoring and security management system for the data center environment. This not only enables real-time monitoring of the data center environment, but also collects relevant information on the operating status of major equipment, and timely discovers some security risks in the data center environment. In physical environments, attention should be paid to dust prevention, temperature and humidity, and resistance to magnetic field interference.
(2) In an electrical environment, dual power supply should be used for power supply in the computer room; The electrical load level and power supply requirements of the computer room shall comply with the current national standards.
3. Layout of the power supply and distribution system in the computer room:
The main equipment of the computer room power supply and distribution system includes: temperature and humidity, water leakage, precision air conditioning, ordinary air conditioning, power supply and distribution, and distribution switches UPS、 Battery, generator, transformer, fire protection, lightning protection, anti-theft, access control, video and other equipment. The power monitoring system for the banyan tree computer room was developed based on the characteristics of various power room constructions. In response to the wide distribution, large number, large number of maintenance personnel, and difficult management and monitoring of power rooms, it ensures centralized management, unified monitoring, and rapid response of power rooms, reduces monitoring and maintenance costs, and improves operation and maintenance quality.
Computer room power monitoring system distribution monitoring
1) Monitoring content:
For important distribution switches in the computer room, monitor whether the switches are tripped or powered off, and monitor the distribution switches on the mains input cabinet Dj in real time. Install a power meter to monitor parameters such as voltage, current, frequency, and power of the incoming power line.
2) Working mode:
Using a dedicated signal processing module with complete optoelectronic isolation, the input strong electrical signal is processed and converted into a low-level signal, which is then input into the intelligent switch quantity acquisition module to convert into data information and sent to the on-site management server to achieve switch status monitoring.
The monitoring of voltage, current, frequency and other parameters of the distribution cabinet mainly adopts a three-phase power detector, which transmits RS485 signals through the built-in power meter to the multi device drive board and connects to the centralized management server to achieve real-time voltage and current monitoring.
3) Implementation function:
Important switch detection function: It can display the status of important distribution switches in the computer room in real time in the system. Once the switch trips or loses power, it can give an alarm in a timely manner, and according to the pre-set alarm strategy, it can display abnormal switches on the interface and achieve automatic alarm screen switching function.
Computer room power monitoring system UPS monitoring
1) Monitoring content:
Monitor one UPS and use UPS to provide remote monitoring communication interface and complete and accurate communication protocol to monitor all status and parameters provided by the protocol. Real time monitoring of analog and digital quantities of UPS.
2) Working mode:
UPS adopts wiring method and directly connects the UPS signal to the on-site management server through RS232/485 conversion module to achieve real-time UPS monitoring.
3) Implementation function:
1. Real time monitoring of the operating status and parameters of various parts of the UPS rectifier, inverter, battery, bypass, load, etc. through the intelligent communication interface and communication protocol provided by the UPS manufacturer. Monitoring parameters include:
2. Analog quantities: input phase voltage, output phase voltage, bypass phase voltage, input phase current, output phase current, bypass phase current, battery voltage, battery current, system frequency, system load, battery backup time.
3. Digital quantity: output voltage exceeds the range, battery working mode, bypass working mode, high battery voltage, low battery voltage, system alarm, system pause, low battery voltage alarm, bypass voltage exceeds the limit, main voltage exceeds the limit.
4. The specific situation of all analog and digital quantities depends on the UPS communication protocol provided by the UPS manufacturer.
havepower and environment monitoring systemmonitoring systemprojectDo you need to move the ring?Just look for Sibe Technology, we have case studies to help you operate projects more easily.Please call: Or consult online!We provide free services for youDynamic environmental monitoring systemProposal and product quotation.
havepower and environment monitoring systemmonitoring systemprojectDo you need to move the ring?Just look for Sibe Technology, we have case studies to help you operate projects more easily.Please call: Or consult online!We provide free services for youDynamic environmental monitoring systemProposal and product quotation.
Online inquiry