Flow sampling system
Product details
FSSFlow sampling system
Monitor and record the flow of rainwater and industrial discharge
FSSFlow sampling systemProduct Introduction:
Product Introduction:
The FSS flow sampling system consists of three parts: a lightweight and easy-to-use mixed water quality sampler, an open channel flow monitor, and a data logger with software, making it easy to carry and install on site. Users can choose different configurations according to their monitoring needs.
The FSS flow sampling system is installed in a sturdy, rainproof lockable carrying case, which includes a 2-gallon (7.57-liter) polyethylene wastewater sampling bottle (for collecting mixed water samples), a peristaltic sampling pump, a control panel (no programming required), and a rechargeable battery, as well as an injection tube and battery charger. Optional glass sampling bottles, portable refrigeration containers, portable ice storage containers, etc.
The FC220 open channel flow monitor is suitable for measuring the flow of various water tanks, weirs, and gravity based open channels. Its traffic data logger provides many practical functions, such as real-time monitoring, interval measurement and engineering unit selection, station numbering, sensor calibration, etc. The recorder software allows for easy viewing of stored data and setting options. The data logger monitors and records the flow rate and total flow rate. The data downloaded from the data logger can be opened with any PC spreadsheet program for analysis and graphical display.


FSSFlow sampling systemKey Features:

·Suitable for wastewater, industrial, and environmental flow sampling
·Sturdy structure, suitable for harsh environments
·Support various types of traffic calculation models
·Traffic ratio sampling triggered
·Adjustable, repetitive sampling capacity
·Peristaltic pump prevents sample contamination
·Traffic data logger compatible with Windows and PDA software
·Easy to operate system


FSSFlow sampling systemTechnical Specifications:

Mixed water sampler
sampling size
50ml-2000ml, 15 non continuous mixed sampling quantities and full bottle sampling can be set
Operating Temperature
0 ~ +70℃
material
Shell: Expanded UV resistant PVC
Sampling bottle: 2.5 gallon polyethylene, optional glass sampling bottle
Sampling tube: 4.5-meter reinforced PVC hose, imported with filter screen
Pump tube: wear-resistant peristaltic tube
sampling pump
Flow rate: 1000ml per minute
Type: Peristaltic pump
Greatest improvement: 6 meters
battery
5AH rechargeable battery. Lifespan: Continuous sampling for 1 hour, standby for 3 months
Open channel flowmeter
Flow rate display
5 digits+decimal point, LCD
Accumulator display
6 digits+decimal point, LCD (only FSS-STD and FSS-LTS)
precision
Pressure sensor ± 0.2% FS+flow monitor ± 0.01%+depth flow meter error
traffic unit
CFS - cubic feet per second, GPM - gallon per minute, m3/s. MGD-1 million gallons per day
Accumulator unit
Associated with traffic units (only FSS-STD and FSS-LTS)
relay contacts
(All models)
voltage
30VDC
current
5A/30VDC
maximum capacity
150W
Relay 1
Pulse output: NPN ground, 1K Ω pull-up resistor, connected to samplers (FSS-STD and FSS-LTS)
Relay 2
Pulse output: NPN ground, open collector, connected to data loggers (FSS-STD and FSS-LTS)
analog output
4-20mA, Resolution 0.005mA
power supply
FSS-STD/LS: Independent 12VDC rechargeable battery, working 60-100mA, sleep 120 μ A
FSS-INT: Shared 12VDC battery with sampler, working 60-100mA, sleep 120 μ A
Pre defined traffic table
parshall flume
1', 2', 3', 6', 9', 12'
Palmer Purus
4', 6', 8', 10', 12', 15'
weir
45 ° V-shaped, 90 ° V-shaped, 1-foot rectangle, 2-foot rectangle
H-shaped groove
0.4HS, 0.6HS, 0.5H, 0.75H, 1.0H, 1.5H, 2.0H
trapezoidal groove
60°
Customized flow meter
Need to provide depth flow formula or checklist
Traffic data logger
memory
Non volatile flash memory
power supply
FSS-STD and FSS-LTS: Independent 12VDC rechargeable batteries
FSS-INT: Shared 12VDC rechargeable battery with sampler
Standby current: 70 μ A
Record current: 5mA+sensor current
Analog input
4-20Ma
Resolution: 12 bits, 4096 steps
Sensor preheating time: 0-60 seconds, programmable
FSS-STD and FSS-INT: 6 input channels+flow rate+battery voltage monitoring
FSS-LTS: 1 input channel+flow rate+battery voltage monitoring
digital input
Maximum input voltage: 24VDC
Zui High Frequency: 100Hz
Zui small pulse width: 2ms
Maximum count: 65535, 16 bits
FSS-STD and FSS-INT: Sampling Events+Total Flow
FSS-LTS: 1 input channel connected to accumulator
Sampling start input
Sampling request input, software activation (only FSS-STD and FSS-INT)
Maximum input voltage: 24VDC
Zui small pulse width: 2ms
Sampling mode
Fixed interval sampling, programmable from 1 second to 1 year
High speed sampling, 10 times per second
Logarithmic sampling
Exception sampling, sampling based on the set deviation
storage capacity
FSS-STD and FSS-INT: a total of 40879 records
FSS-LTS: A total of 81759 records
Data Coverage: Optional loop coverage or stop recording when full
通信端口
FSS-STD and FSS-INT: RS-232 DB9 or USB-B
FSS-LTS: RS-232, 4-pin circular connector
Baud rates: 9600, 19200, 28800, 38400, 57600, 115200
clock
Synchronize with user's computer date and time
Operating Temperature
-40~+85℃
Data logger software
Windows 98, ME, 2000, NT, XP 兼容
List display/print data format: Standard Spreadsheet (. CSV)
Programmable alarm start and stop
On site calibration software and assistance files
mechanical parameters
FSS-STD
2 carrying cases
Sampler box: 560 × 430 × 230 mm, 9kg
Recorder box: 170 × 250 × 150 mm, 6.4kg
FSS-LTS
2 carrying cases
Sampler box: 560 × 430 × 230 mm, 9kg
Recorder box: 170 × 250 × 150 mm, 5.9kg
FSS-INT
1 carrying case, 560 × 430 × 230 mm, 10kg


FSSFlow sampling systemStandard configuration:
model
description
FSS-STD
FSS-STD flow sampling system, including WS700 flow ratio mixed water sampler, FC200 open channel flowmeter, GL500-7 flow data logger, user manual
FSS-LTS
FSS-LTS flow sampling system, including WS700 flow ratio mixed water sampler, FC200 open channel flowmeter with built-in GL500-2 flow data recorder, user manual
FSS-INT
FSS-INT integrated flow sampling system, WS700 flow proportional mixed water sampler with built-in FC210 open channel flowmeter and GL500-2 flow data recorder, optional WS750 sampler configuration, user manual
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!