VIP member
Product details
FSSFlow sampling system
Monitor and record the flow of rainwater and industrial discharge
FSSFlow sampling systemProduct Introduction:
Product Introduction:
The FSS flow sampling system consists of three parts: a lightweight and easy-to-use mixed water quality sampler, an open channel flow monitor, and a data logger with software, making it easy to carry and install on site. Users can choose different configurations according to their monitoring needs.
The FSS flow sampling system is installed in a sturdy, rainproof lockable carrying case, which includes a 2-gallon (7.57-liter) polyethylene wastewater sampling bottle (for collecting mixed water samples), a peristaltic sampling pump, a control panel (no programming required), and a rechargeable battery, as well as an injection tube and battery charger. Optional glass sampling bottles, portable refrigeration containers, portable ice storage containers, etc.
The FC220 open channel flow monitor is suitable for measuring the flow of various water tanks, weirs, and gravity based open channels. Its traffic data logger provides many practical functions, such as real-time monitoring, interval measurement and engineering unit selection, station numbering, sensor calibration, etc. The recorder software allows for easy viewing of stored data and setting options. The data logger monitors and records the flow rate and total flow rate. The data downloaded from the data logger can be opened with any PC spreadsheet program for analysis and graphical display.
FSSFlow sampling systemKey Features:
·Suitable for wastewater, industrial, and environmental flow sampling
·Sturdy structure, suitable for harsh environments
·Support various types of traffic calculation models
·Traffic ratio sampling triggered
·Adjustable, repetitive sampling capacity
·Peristaltic pump prevents sample contamination
·Traffic data logger compatible with Windows and PDA software
·Easy to operate system
FSSFlow sampling systemTechnical Specifications:
|
Mixed water sampler
|
|
|
sampling size
|
50ml-2000ml, 15 non continuous mixed sampling quantities and full bottle sampling can be set
|
|
Operating Temperature
|
0 ~ +70℃
|
|
material
|
Shell: Expanded UV resistant PVC
Sampling bottle: 2.5 gallon polyethylene, optional glass sampling bottle
Sampling tube: 4.5-meter reinforced PVC hose, imported with filter screen
Pump tube: wear-resistant peristaltic tube
|
|
sampling pump
|
Flow rate: 1000ml per minute
Type: Peristaltic pump
Greatest improvement: 6 meters
|
|
battery
|
5AH rechargeable battery. Lifespan: Continuous sampling for 1 hour, standby for 3 months
|
|
Open channel flowmeter
|
|
|
Flow rate display
|
5 digits+decimal point, LCD
|
|
Accumulator display
|
6 digits+decimal point, LCD (only FSS-STD and FSS-LTS)
|
|
precision
|
Pressure sensor ± 0.2% FS+flow monitor ± 0.01%+depth flow meter error
|
|
traffic unit
|
CFS - cubic feet per second, GPM - gallon per minute, m3/s. MGD-1 million gallons per day
|
|
Accumulator unit
|
Associated with traffic units (only FSS-STD and FSS-LTS)
|
|
relay contacts
|
(All models)
|
|
voltage
|
30VDC
|
|
current
|
5A/30VDC
|
|
maximum capacity
|
150W
|
|
Relay 1
|
Pulse output: NPN ground, 1K Ω pull-up resistor, connected to samplers (FSS-STD and FSS-LTS)
|
|
Relay 2
|
Pulse output: NPN ground, open collector, connected to data loggers (FSS-STD and FSS-LTS)
|
|
analog output
|
4-20mA, Resolution 0.005mA
|
|
power supply
|
FSS-STD/LS: Independent 12VDC rechargeable battery, working 60-100mA, sleep 120 μ A
FSS-INT: Shared 12VDC battery with sampler, working 60-100mA, sleep 120 μ A
|
|
Pre defined traffic table
|
|
|
parshall flume
|
1', 2', 3', 6', 9', 12'
|
|
Palmer Purus
|
4', 6', 8', 10', 12', 15'
|
|
weir
|
45 ° V-shaped, 90 ° V-shaped, 1-foot rectangle, 2-foot rectangle
|
|
H-shaped groove
|
0.4HS, 0.6HS, 0.5H, 0.75H, 1.0H, 1.5H, 2.0H
|
|
trapezoidal groove
|
60°
|
|
Customized flow meter
|
Need to provide depth flow formula or checklist
|
|
Traffic data logger
|
|
|
memory
|
Non volatile flash memory
|
|
power supply
|
FSS-STD and FSS-LTS: Independent 12VDC rechargeable batteries
FSS-INT: Shared 12VDC rechargeable battery with sampler
Standby current: 70 μ A
Record current: 5mA+sensor current
|
|
Analog input
|
4-20Ma
Resolution: 12 bits, 4096 steps
Sensor preheating time: 0-60 seconds, programmable
FSS-STD and FSS-INT: 6 input channels+flow rate+battery voltage monitoring
FSS-LTS: 1 input channel+flow rate+battery voltage monitoring
|
|
digital input
|
Maximum input voltage: 24VDC
Zui High Frequency: 100Hz
Zui small pulse width: 2ms
Maximum count: 65535, 16 bits
FSS-STD and FSS-INT: Sampling Events+Total Flow
FSS-LTS: 1 input channel connected to accumulator
|
|
Sampling start input
|
Sampling request input, software activation (only FSS-STD and FSS-INT)
Maximum input voltage: 24VDC
Zui small pulse width: 2ms
|
|
Sampling mode
|
Fixed interval sampling, programmable from 1 second to 1 year
High speed sampling, 10 times per second
Logarithmic sampling
Exception sampling, sampling based on the set deviation
|
|
storage capacity
|
FSS-STD and FSS-INT: a total of 40879 records
FSS-LTS: A total of 81759 records
Data Coverage: Optional loop coverage or stop recording when full
|
|
通信端口
|
FSS-STD and FSS-INT: RS-232 DB9 or USB-B
FSS-LTS: RS-232, 4-pin circular connector
Baud rates: 9600, 19200, 28800, 38400, 57600, 115200
|
|
clock
|
Synchronize with user's computer date and time
|
|
Operating Temperature
|
-40~+85℃
|
|
Data logger software
|
Windows 98, ME, 2000, NT, XP 兼容
List display/print data format: Standard Spreadsheet (. CSV)
Programmable alarm start and stop
On site calibration software and assistance files
|
|
mechanical parameters
|
|
|
FSS-STD
|
2 carrying cases
Sampler box: 560 × 430 × 230 mm, 9kg
Recorder box: 170 × 250 × 150 mm, 6.4kg
|
|
FSS-LTS
|
2 carrying cases
Sampler box: 560 × 430 × 230 mm, 9kg
Recorder box: 170 × 250 × 150 mm, 5.9kg
|
|
FSS-INT
|
1 carrying case, 560 × 430 × 230 mm, 10kg
|
FSSFlow sampling systemStandard configuration:
|
model
|
description
|
|
FSS-STD
|
FSS-STD flow sampling system, including WS700 flow ratio mixed water sampler, FC200 open channel flowmeter, GL500-7 flow data logger, user manual
|
|
FSS-LTS
|
FSS-LTS flow sampling system, including WS700 flow ratio mixed water sampler, FC200 open channel flowmeter with built-in GL500-2 flow data recorder, user manual
|
|
FSS-INT
|
FSS-INT integrated flow sampling system, WS700 flow proportional mixed water sampler with built-in FC210 open channel flowmeter and GL500-2 flow data recorder, optional WS750 sampler configuration, user manual
|
Online inquiry