1、 JMHVS-5/10/30/50-XYZ Fully Automatic Precision Vickers Hardness Tester - "Aolongxin" Features:
High precision step controlled electric loading technology
The loading speed of the main test force is extremely fast, resulting in improved efficiency
High precision sensors combined with the Aolongxin control system
Aolongxin's unique force value curve chart
Faster and more precise loading and unloading speed
Can achieve remote control, easy to operate
Extremely fast loading speed: test force loading time 2-6 seconds
Intelligent control throughout the entire process. Segmented force application, smooth variable speed, high-precision and high-speed step control, etc
2、 JMHVS-5/10/30/50-XYZ Fully Automatic Precision Vickers Hardness Tester - Main Technical Parameters:
|
model |
JMHVS-5-XYZ |
JMHVS-10-XYZ |
JMHVS-30-XYZ |
JMHVS-50-XYZ |
|
Test force (kgf) |
0.2, 0.3, 0.5, 1, 2, 2.5, 3, 5 |
0.3, 0.5, 1, 2, 2.5, 3, 5, 10 |
0.5, 1, 2, 3, 5, 10, 20, 30 |
1. 2, 3, 5, 10, 20, 30, 50 |
|
loading method |
Automatic loading and unloading |
|||
|
Test force switching |
automatic |
|||
|
Language Selection |
Chinese-English translation |
|||
|
holding time |
5-60s |
|||
|
Pressure head objective lens switching |
Auto Switch |
|||
|
Testeable parameters |
HV/HK |
|||
|
objective lens |
10 times, 20 times |
|||
|
Digital encoder micrometer eyepiece |
10 times |
|||
|
*Large measurement length |
400um |
|||
|
*Small scale division |
0.1um |
|||
|
Sample * Large Height |
215mm |
|||
|
Sample * large depth |
160mm |
|||
|
Hardness conversion |
HV、HK、HRA、HRB、HRC、HRD、HRE、HRF、HRG、HRK、HR15N、HR30N、HR45N、 HR15T、HR30T、HR45T、HBW |
|||
|
Touch screen operation panel |
Force curve, options, database, control, loading start, light adjustment, objective lens switching |
|||
|
numerical display |
D1, D2 values, HV, HK indication, hardness value, conversion value, holding time, test frequency |
|||
|
light source |
5V/12V light bulb |
|||
|
communication interface |
RS 232 |
|||
|
execution standard |
JJG151,GB/T 4340,ISO/DIN6507,ASTM E-384 |
|||
|
power supply |
AC220V±5%,50-60Hz |
|||
|
Overall dimensions |
Length 510 * Width 310 * Height 600mm |
|||
|
Net weight of the machine |
About 70kg |
|||
|
|
|
|||
3、 JMHVS-5/10/30/50-XYZ Fully Automatic Precision Vickers Hardness Tester - Host Standard Configuration:
|
name |
quantity |
name |
quantity |
|
Cross test bench |
1 piece |
Thin film clamping table |
1 piece |
|
Flat mouth clamping table |
1 piece |
Fine thread support table |
1 piece |
|
screwdriver |
2 of them |
Horizontal adjustment screw |
4 pieces |
|
10x micrometer eyepiece |
1 piece |
Microhardness block |
2 pieces |
|
spare bulb |
2 pieces |
spare fuses |
2 pieces |
|
level gauge |
1 piece |
Product Qualification Certificate |
1 copy |
|
Product User Manual |
1 copy |
|
|
Fully automatic measurement system
Product Introduction
The fully automatic Vickers hardness image measurement system integrates various new professional technologies such as optical imaging, mechanical displacement, electronic control, digital imaging, image analysis, and computer processing. It controls the micro Vickers hardness tester and automatic stage through the computer host, and digitizes the hardness indentation on the computer screen. Then, through automatic reading, manual reading and other means, it accurately measures the micro hardness, hardening layer depth, film thickness, two-point spacing, etc. of metal and some non-metallic materials, as well as various film layers and coatings. It can also capture the surface morphology of metals and perform fixed magnification printing. This system breaks through the traditional hardness testing method and achieves fully automated, high-precision, and highly repeatable hardness testing, making it an important equipment for material analysis.
Feature Introduction
·XYZ sample movement control: The system supports XY electric movement of the sample stage and Z-axis control; Including manual control, electric control (joystick control), and automatic control (software control). The X-Y direction can move synchronously. The electric control adopts a three-dimensional joystick control, based on ergonomic principles, simple and convenient, and allows for free movement.
·Software control and loading mode
Positioning and Mobile Loading: The platform is directly moved to the software set position and loaded;
Fixed point moving loading: Select any point on the sample, move it below the pressure head and load it;
Directional movement loading: Click the mouse to control the loading platform to move in eight directions freely, and the movement step distance can be set and loaded;
Loading at any position: Drag the mouse to move the stage in any direction, making it easy for users to browse the surface condition of the sample; And the loading point can be set at any position;
Variable speed movement: When the platform moves, there are five speed options available;
Other functions: various professional functions such as arbitrary setting of origin position, automatic reset, mechanical limit, etc., to meet various needs;
·Fully automatic operation: The system automatically moves, rotates, loads, focuses, and measures at multiple points according to the set path, and automatically draws the hardening curve;
·Hardness value conversion, correction, and effective verification: The system can convert the measured micro Vickers hardness value into other hardness values such as HB, HR, etc; Can effectively verify the measured values of the sample.
Technical parameters of fully automatic precision Vickers hardness tester
|
execution standard |
GBT4340.1,GBT4340.2,ASTM_E92 |
|
Test force application method |
Automatic (loading, holding, unloading) |
|
XYZ sample stage and movement control |
The system provides XY electric moving sample stage and Z-axis control: 1. XY stroke: 50mm * 50mm Table size: 200mmX180mm, displacement repeatability<2um; XYZ displacement resolution can reach 2um; 2. XYZ movement speed can be adjusted 3. You can click the mouse to control the movement, or move or lift by inputting the movement distance, etc 4. The XY and Z movements can be controlled with a joystick, and the position can be fed back in a timely manner. |
|
Loading mode and path settings |
Multiple methods ensure that users can still obtain satisfactory measurement results even when the sample placement is not vertical or horizontal. Two point method: Click on any two points on the sample image to specify the direction of movement of the stage; Normal method: Select the normal tangent to the edge of the specimen as the direction of movement for the stage; Angle bisector: By selecting the angle, the direction of the bisector is used as the direction of sample movement; Arbitrary point method: Move the platform to any position, add loading points, and then load and measure at once. Random point loading: Double click at any position on the platform, and the platform will automatically move the point to the center of the indenter field of view for loading and measurement. Path adjustment: For the selected path, various operations such as horizontal mirror orientation, vertical mirror orientation, 90 degree, 180 degree, arbitrary angle rotation, and position translation can be performed. |
|
fully automatic measurement |
Automatically load point by point according to the set loading path, automatically focus, and automatically measure indentation to calculate hardness values, and draw a hardening curve; |
|
Camera and calibration management |
1.3 million pixel USB 2.0 CMOS dedicated for microscope measurement cameras 2. The camera can be calibrated using either a hardness calibration block or a calibration ruler 3. In order to improve measurement accuracy, different test forces can be calibrated separately and the system will automatically load them |
|
Hardness value conversion and correction |
Hardness conversion: The measured Vickers hardness value can be converted to other hardness values such as HB, HR, etc. in American, Chinese, or German standards; |
|
data statistics |
Automatically calculate statistical values such as the average and variance of hardness |
|
Measurement algorithm |
1. Superior automatic reading technology - Superior automatic reading technology can not only obtain sub-pixel, high-precision, and high repeatability results, but also is suitable for general indentation images, including images with small amounts of rust, scratches, uneven lighting, and shallow corrosion, with extremely fast measurement speed; 2. Unique manual point taking and automatic point finding technology - Users can roughly point near the four vertices of the indentation, and the system automatically identifies the best vertex position and reads directly; Satisfying the habits of ordinary users while greatly reducing their labor intensity; 3. General manual measurement methods - including 4-point measurement, 2-diagonal measurement, etc. When measuring 4 vertices, 4 vertices can be selected in any order for the convenience of users. |
|
Hardening curve |
Automatically draw hardening curve: |
|
data storage |
The original measurement data and images can be saved in the document for later calling out and printing the report; One file stores all the data of one measurement |
|
Test Report |
Automatically generate WORD or EXCEL document reports; The report format can be customized; The standard format includes hardness values, statistical values, indentation images, and hardening curves for each individual measurement point |
|
Knoop hardness |
Can be set for Knoop hardness measurement |
Software standard configuration
|
name |
quantity |
name |
quantity |
|
XY electric platform |
1 piece |
3D platform control box |
1 piece |
|
power cord |
1 piece |
USB cable |
1 piece |
|
XYZ connection line |
1 set |
Software installation CD |
1 piece |
|
3 million dedicated camera |
1 piece |
Brand desktop computer |
1 set |
|
dongle |
1 piece |
|
|
Fully automatic precision Vickers hardness testerVersion Description
Fully automatic hardness image measurement system: XY electric platform+3 million digital camera+XYZ 3D platform control box+fully automatic hardness image software (automatic platform, automatic focus, automatic turret, automatic loading, automatic reading)