Generator load testing cabinet
Host Introduction: Customizable according to the requirements of the generator's factory load test
Product details
Instrument Name: Generator Load Cabinet
Instrument model: FZ series
Features: The FZ-106 single-phase generator set (6kW) load testing system is based on the requirements of the factory test of single-phase generator sets, consisting of GDW1200C (or GDW1200A) single-phase electrical parameters and load resistors. Each load group is composed of two identical resistors, and load switching and regulation control can be performed on generator sets with rated voltages of 220V and 110V through a conversion switch.
The FZ-110 single-phase generator set (10KW) load tester is composed of GDW1400 single-phase electrical parameters and load resistors according to the requirements of the factory test of single-phase generator sets. Each load group is composed of two identical resistors, and the load switching and adjustment control of the rated voltage 220V and 110V generator sets can be carried out through a conversion switch.
The FZ-310 single/three-phase generator load testing system is developed based on the requirements of the generator's factory load test. The entire machine is composed of full resistance loads, with three-phase loads connected to A, B, C phases and neutral line N, and single-phase loads connected to A phase and neutral line (neutral line). Each load group consists of three sets of resistors.
1) Measurement range: Voltage (0-500) V
Power: Three phase: (0~10) kW
Single phase (220V): (0~10) kW; Single phase (110V): (0~10) kW
2) Usage conditions: Working power supply: AC220V ± 22V, 50Hz ± 2Hz
Environmental temperature: (0~35) ℃
The FZ-315 single/three-phase generator load testing system is based on the requirements of the generator factory load test: the whole machine is composed of full resistance loads, with three-phase loads connected to A, B, C phases and neutral line N, and single-phase loads connected to A phase and neutral line (neutral line). Each load group consists of three sets of resistors.
1) Measurement range: Voltage (0-500) V
Power: Three phase: (0~15) kW,
Single phase (240V): (0~15) kW. Single phase (120V): 0~12kW
2) Usage conditions: Working power supply: AC220V ± 22V, 50Hz ± 2Hz