German MRU DELTA65 flue gas analyzer
Through German T ü V quality certification, certification number ByRgG 227 continuous analysis and measurement: O2-CO-CO2- flue gas temperature - ambi
Product details

Passed German T ü V quality certification, certification number ByRgG 227

Continuous analysis and measurement: O2-CO-CO2- flue gas temperature - ambient temperature

Calculation: CO2- mg/m3- combustion efficiency - exhaust heat loss - excess air coefficient - CO/CO2 ratio

Characteristics

Rubber instrument protective cover with magnetic backplate

● Multi stage smoke and dust filter and air-water separator

High definition large screen LCD display, displaying 4 lines of data

180mm sampling probe? 8 mm, 1.5-meter sampling pipeline

The infrared printer interface is suitable for non-contact printing of data

The data storage can store 100 sets of data

RS232 interface, capable of downloading data to a PC

● Built in battery or external power supply

Rechargeable battery that can work for up to 8 hours

● 230Vac power cord for charger

Durable and sturdy, specifically designed for on-site applications

Electrochemical sensors measure quickly and with high accuracy

Compact and lightweight handheld combustion efficiency tester

Standard Configuration

Continuous analysis and measurement of O2 and CO (only one CO range can be selected)

Separate the measurement of flue gas temperature and ambient temperature, and measure the pressure in the flue gas

RS232 computer interface, 100 sets of data storage, infrared printer interface

180mm sampling probe, diameter 8mm, 1500mm sampling pipeline

● Calculation: CO/CO2 ratio mg/m3 、CO2、 Excess air coefficient λ, combustion efficiency, exhaust heat loss

Standard mode instrument box (can hold spare parts for instruments inside)

Technical Specifications

measurement parameters

measurement range

resolution

precision

Oxygen O2

0-20.9%

0.1%

*Less than+0.2%

Carbon monoxide CO

0-2000 ppm (small range)

1ppm

+5% of the measured value

Carbon monoxide CO

0-10000 ppm (standard range)

1ppm

+5% of the measured value

Flue gas temperature T-gas

0-650 ℃ nickel chromium nickel thermocouple

0.1℃

+1% of the measured value

Environmental temperature T-room

0-50℃

0.1℃

+1% of the measured value

Working temperature 5-45 ℃

Storage temperature -20-50 ℃

Power supply from battery: approximately 8 hours

Size 150X200X55 mm (instrument only) Weight: Approximately 500 grams

Application field



Environmental monitoring station

paper mill

chemical industry

Ceramic manufacturing industry

Brewing and manufacturing industry

Thermal power plant

garbage incineration plant

automobile manufacturing industry

University Research Institute

Boiler system testing




Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!