Passed German T ü V quality certification, certification number ByRgG 227
Continuous analysis and measurement: O2-CO-CO2- flue gas temperature - ambient temperature
Calculation: CO2- mg/m3- combustion efficiency - exhaust heat loss - excess air coefficient - CO/CO2 ratio
Characteristics
Rubber instrument protective cover with magnetic backplate
● Multi stage smoke and dust filter and air-water separator
High definition large screen LCD display, displaying 4 lines of data
180mm sampling probe? 8 mm, 1.5-meter sampling pipeline
The infrared printer interface is suitable for non-contact printing of data
The data storage can store 100 sets of data
RS232 interface, capable of downloading data to a PC
● Built in battery or external power supply
Rechargeable battery that can work for up to 8 hours
● 230Vac power cord for charger
Durable and sturdy, specifically designed for on-site applications
Electrochemical sensors measure quickly and with high accuracy
Compact and lightweight handheld combustion efficiency tester
Standard Configuration
Continuous analysis and measurement of O2 and CO (only one CO range can be selected)
Separate the measurement of flue gas temperature and ambient temperature, and measure the pressure in the flue gas
RS232 computer interface, 100 sets of data storage, infrared printer interface
180mm sampling probe, diameter 8mm, 1500mm sampling pipeline
● Calculation: CO/CO2 ratio mg/m3 、CO2、 Excess air coefficient λ, combustion efficiency, exhaust heat loss
Standard mode instrument box (can hold spare parts for instruments inside)
Technical Specifications
measurement parameters |
measurement range |
resolution |
precision |
|||||||||||||||
Oxygen O2 |
0-20.9% |
0.1% |
*Less than+0.2% |
|||||||||||||||
Carbon monoxide CO |
0-2000 ppm (small range) |
1ppm |
+5% of the measured value |
|||||||||||||||
Carbon monoxide CO |
0-10000 ppm (standard range) |
1ppm |
+5% of the measured value |
|||||||||||||||
Flue gas temperature T-gas |
0-650 ℃ nickel chromium nickel thermocouple |
0.1℃ |
+1% of the measured value |
|||||||||||||||
Environmental temperature T-room |
0-50℃ |
0.1℃ |
+1% of the measured value |
|||||||||||||||
Working temperature 5-45 ℃ | ||||||||||||||||||
Storage temperature -20-50 ℃ | ||||||||||||||||||
Power supply from battery: approximately 8 hours | ||||||||||||||||||
|
Size 150X200X55 mm (instrument only) Weight: Approximately 500 grams
| ||||||||||||||||||