● Adopting high-frequency voltage doubling circuit, applicationPWMPulse Width Modulation Technology and High PowerIGBTDevices.
Adopting high voltage feedback, the output voltage stability is high, and the ripple coefficient is small ≤1%.
Smooth voltage regulation across the entire range, with fine voltage regulation and precise adjustment accuracy ≤0.5%Stability ≤1%Voltage and current error1%(Reading ±)0.2KV)Current error ±1One word.
The boost potentiometer boosts the voltage from zero.
●75%UDC1mAFunction button, convenient for testing zinc oxide lightning arrester, accuracy1%Reading ±1%.
Overvoltage protection adopts dip code setting, which is clear at a glance and has an error of ±1%.
The double pressure adopts new materials, which are lightweight and sturdy. The exterior is coated with special insulation material, which has good electrical performance and strong moisture resistance.
Folding support feet, with a large diameter area and good stability performance.
●HDKZG40KVIntegrated design, high-voltage grounding cable lead out, convenient for on-site testing.
●HDKZGThe product complies withDL/T848.1-2004Technical requirements and type testing conducted by the Electrical Equipment Quality Inspection and Testing Center of the Ministry of Electric Power, strictly following the enterprise standard for factory delivery.
1Technical Specifications:
1.1 Integrated machine
|
Specifications Technical Specifications |
40/3 |
60/2 |
60/3 |
60/5 |
60/10 |
100/2 |
120/2 |
120/10 |
|
Rated voltage(KV) |
40 |
60 |
60 |
60 |
60 |
100 |
120 |
120 |
|
Rated currentmA) |
3 |
2 |
3 |
5 |
10 |
2 |
2 |
10 |
|
Rated powerW) |
120 |
120 |
180 |
300 |
600 |
200 |
240 |
1200 |
|
Chassis weight(kg) |
2 |
2 |
2 |
4.5 |
5.5 |
3 |
3 |
4.5 |
|
Double pressure weight(kg) |
2 |
2.5 |
3 |
3.8 |
4.2 |
4 |
4 |
4.5 |
|
Double pressure height(mm) |
400 |
400 |
400 |
500 |
500 |
500 |
500 |
500 |
|
Voltage measurement accuracy |
Digital display meter ±(1%Reading ±2One word) |
|||||||
|
Accuracy of current measurement |
Digital display meter ±(1%Reading ±2One word) |
|||||||
|
Ripple coefficient |
≤1% |
|||||||
|
voltage stability |
Random fluctuations, changes in power supply voltage ±10%Time ≤1% |
|||||||
|
overload capacity |
The no-load voltage may exceed the rated voltage10%Use for ten minutes The maximum charging current is1.5Double rated current |
|||||||
|
power supply |
Single-phase AC50Hz 220V±10% |
|||||||
|
working method |
Intermittent use |
|||||||
|
The longest continuous time is30minute |
||||||||
|
working environment |
temperature-10~40℃ |
|||||||
|
Relative humidity: Room temperature is25Not greater than at ℃85%(No condensation) |
||||||||
|
Altitude:1500Below meters |
||||||||
|
With capacitor Load capacity |
The capacitance of the test sample is unlimited |
|||||||
|
available1.5Charging at times the rated current |
||||||||
|
structural characteristics |
Epoxy fiberglass electrical insulation double pressure cylinder |
|||||||
|
Air insulation, no leakage concerns |
||||||||
|
Characteristics of the operation box |
high precision0.75UDC1mAOne touch button (accuracy ≤1%)The most suitable test for zinc oxide lightning arrester |
|||||||
|
Overvoltage protection adopts a toggle setting, which is clear at a glance |
||||||||
|
Place an aluminum alloy box with double voltage on the chassis, and the entire machine can be lifted with one hand |
||||||||
1.2 Split machine
|
Specifications Technical Specifications |
200/2 |
200/3 |
200/10 |
300/2 |
300/5 |
400/3 |
400/5 |
Other levels |
|
Rated voltage(KV) |
200 |
200 |
200 |
300 |
300 |
400 |
400 |
500~1000KVfixed do |
|
Rated currentmA) |
2 |
3 |
10 |
2 |
5 |
3 |
5 |
|
|
Rated powerW) |
400 |
600 |
2000 |
600 |
1500 |
1200 |
2000 |
|
|
Chassis weight(kg) |
4.5 |
4.5 |
4.5 |
5.5 |
5.5 |
5.5 |
6.5 |
|
|
Double pressure weight(kg) |
7.9 |
8.3 |
10 |
11 |
11.5 |
38 |
40 |
|
|
Double pressure height(mm) |
965 |
965 |
1030 |
1250 |
1250 |
1900 |
1900 |
|
|
Voltage measurement accuracy |
Digital display meter ±(1%Reading ±2One word) |
|||||||
|
Accuracy of current measurement |
Digital display meter ±(1%Reading ±2One word) |
|||||||
|
Ripple coefficient |
≤1% |
|||||||
|
voltage stability |
Random fluctuations, changes in power supply voltage ±10%Time ≤1% |
|||||||
|
overload capacity |
The no-load voltage may exceed the rated voltage10%Use for ten minutes The maximum charging current is1.5Double rated current |
|||||||
|
power supply |
Single-phase AC50Hz 220V±10% |
|||||||
|
working method |
Intermittent use |
|||||||
|
The longest continuous time is30minute |
||||||||
|
working environment |
temperature-10~40℃ |
|||||||
|
Relative humidity: Room temperature is25Not greater than at ℃85%(No condensation) |
||||||||
|
Altitude:1500Below meters |
||||||||
|
With capacitor Load capacity |
The capacitance of the test sample is unlimited |
|||||||
|
available1.5Charging at times the rated current |
||||||||
|
structural characteristics |
Epoxy fiberglass electrical insulation double pressure cylinder |
|||||||
|
Air insulation, no leakage concerns |
||||||||
|
Characteristics of the operation box |
high precision0.75UDC1mAOne touch button (accuracy ≤1%)The most suitable test for zinc oxide lightning arrester |
|||||||
|
Overvoltage protection adopts a toggle setting, which is clear at a glance |
||||||||
|
Small control box, convenient for on-site use |
||||||||