HDKZG-II 400kV2mA High Voltage DC Generator
Equipment Name: High Voltage DC Generator Model: HDKZG-II400kV2mA Quantity: 1 set Manufacturer: Wuhan Huadian Keyi Electric Co., Ltd. Keywords: High V
Product details
Product Overview
The HDKZG series high-voltage DC generator (also known as DC high-voltage tester) is a new generation of portable DC high-voltage tester designed and manufactured according to the new Chinese power grid standard DL/T848.1-2004 "General Technical Conditions for DC High Voltage Generators". Mainly suitable for power departments of enterprises such as electric power, metallurgy, and steel to conduct DC withstand voltage tests on high-voltage electrical equipment such as zinc oxide lightning arresters, power cables, transformers, and generators.
Features


● Adopting high-frequency voltage doubling circuit, applicationPWMPulse Width Modulation Technology and High PowerIGBTDevices.

Adopting high voltage feedback, the output voltage stability is high, and the ripple coefficient is small ≤1%.

Smooth voltage regulation across the entire range, with fine voltage regulation and precise adjustment accuracy ≤0.5%Stability ≤1%Voltage and current error1%(Reading ±)0.2KV)Current error ±1One word.

The boost potentiometer boosts the voltage from zero.

75%UDC1mAFunction button, convenient for testing zinc oxide lightning arrester, accuracy1%Reading ±1%.

Overvoltage protection adopts dip code setting, which is clear at a glance and has an error of ±1%.

The double pressure adopts new materials, which are lightweight and sturdy. The exterior is coated with special insulation material, which has good electrical performance and strong moisture resistance.

Folding support feet, with a large diameter area and good stability performance.

HDKZG40KVIntegrated design, high-voltage grounding cable lead out, convenient for on-site testing.

HDKZGThe product complies withDL/T848.1-2004Technical requirements and type testing conducted by the Electrical Equipment Quality Inspection and Testing Center of the Ministry of Electric Power, strictly following the enterprise standard for factory delivery.

Detailed specifications


1Technical Specifications:

1.1 Integrated machine

Specifications

Technical Specifications

40/3

60/2

60/3

60/5

60/10

100/2

120/2

120/10

Rated voltage(KV

40

60

60

60

60

100

120

120

Rated currentmA

3

2

3

5

10

2

2

10

Rated powerW

120

120

180

300

600

200

240

1200

Chassis weight(kg

2

2

2

4.5

5.5

3

3

4.5

Double pressure weight(kg

2

2.5

3

3.8

4.2

4

4

4.5

Double pressure height(mm

400

400

400

500

500

500

500

500

Voltage measurement accuracy

Digital display meter ±(1%Reading ±2One word)

Accuracy of current measurement

Digital display meter ±(1%Reading ±2One word)

Ripple coefficient

1%

voltage stability

Random fluctuations, changes in power supply voltage ±10%Time ≤1%

overload capacity

The no-load voltage may exceed the rated voltage10%Use for ten minutes

The maximum charging current is1.5Double rated current

power supply

Single-phase AC50Hz 220V±10%

working method

Intermittent use

The longest continuous time is30minute

working environment

temperature-1040

Relative humidity: Room temperature is25Not greater than at ℃85%(No condensation)

Altitude:1500Below meters

With capacitor

Load capacity

The capacitance of the test sample is unlimited

available1.5Charging at times the rated current

structural characteristics

Epoxy fiberglass electrical insulation double pressure cylinder

Air insulation, no leakage concerns

Characteristics of the operation box

high precision0.75UDC1mAOne touch button (accuracy ≤1%)The most suitable test for zinc oxide lightning arrester

Overvoltage protection adopts a toggle setting, which is clear at a glance

Place an aluminum alloy box with double voltage on the chassis, and the entire machine can be lifted with one hand

1.2 Split machine

Specifications

Technical Specifications

200/2

200/3

200/10

300/2

300/5

400/3

400/5

Other levels

Rated voltage(KV

200

200

200

300

300

400

400

5001000KVfixed do

Rated currentmA

2

3

10

2

5

3

5

Rated powerW

400

600

2000

600

1500

1200

2000

Chassis weight(kg

4.5

4.5

4.5

5.5

5.5

5.5

6.5

Double pressure weight(kg

7.9

8.3

10

11

11.5

38

40

Double pressure height(mm

965

965

1030

1250

1250

1900

1900

Voltage measurement accuracy

Digital display meter ±(1%Reading ±2One word)

Accuracy of current measurement

Digital display meter ±(1%Reading ±2One word)

Ripple coefficient

1%

voltage stability

Random fluctuations, changes in power supply voltage ±10%Time ≤1%

overload capacity

The no-load voltage may exceed the rated voltage10%Use for ten minutes

The maximum charging current is1.5Double rated current

power supply

Single-phase AC50Hz 220V±10%

working method

Intermittent use

The longest continuous time is30minute

working environment

temperature-1040

Relative humidity: Room temperature is25Not greater than at ℃85%(No condensation)

Altitude:1500Below meters

With capacitor

Load capacity

The capacitance of the test sample is unlimited

available1.5Charging at times the rated current

structural characteristics

Epoxy fiberglass electrical insulation double pressure cylinder

Air insulation, no leakage concerns

Characteristics of the operation box

high precision0.75UDC1mAOne touch button (accuracy ≤1%)The most suitable test for zinc oxide lightning arrester

Overvoltage protection adopts a toggle setting, which is clear at a glance

Small control box, convenient for on-site use