HT-PM-300BR Dust Online Monitoring System (β - Ray)
HT-PM-300BR dust online monitoring system (β - ray) In recent years, the domestic environmental protection industry has developed rapidly, and a large
Product details
HT-PM-300BR Dust Online Monitoring System (β - Ray)
In recent years, the domestic environmental protection industry has developed rapidly, and a large number of new environmental protection enterprises have begun to develop high-tech instruments and equipment. There are dust monitoring systems, VOC monitoring equipment, negative oxygen ion monitoring instruments, etc., among which the application demand for dust monitoring systems is more extensive.
Product Features:
This device has functions such as online monitoring of particulate matter concentration, environmental temperature and humidity, alarm, wind speed and direction, noise monitoring, and video recording transmission and capture. The device consists of a video surveillance system, an online particulate matter monitor, a data collection and transmission system, a data integration and information collection platform. Secondly, the device has powerful functions, simple operation, and accurate detection, and can achieve 24-hour operation.
HT-PM-300BR Dust Online Monitoring System (β - Ray)
performance metrics
project
performance metrics
principle
β - ray absorption method
Concentration measurement range
(0~10)mg/m3
detection limit
1μg/m3
indication error
Not greater than ± 20%
indication repeatability
Not exceeding 10%
Clock Error
Not exceeding ± 20s, in normal working condition
Not more than ± 2 minutes, in power-off state
Temperature measurement indication error
Not greater than ± 2 ℃, (-30~50) ℃
Traffic stability
Set flow rate to ± 8% within 24 hours
Set flow rate to ± 4%, 24-hour average flow rate
temporal resolution
60s
Calibration membrane reproducibility
Not greater than ± 2% (nominal value)
Voltage variation stability
The variation of the measured value of the standard membrane shall not exceed ± 5% (nominal value)
parallelism
≤10%
Comparison testing of reference methods
Slope: 1 ± 0.15; Intercept: (0 ± 10) μ g/m3; Correlation coefficient ≥ 0.95
Data efficiency
Not less than 85%
Meteorological five parameter technical indicators
name
measurement range
Technical Requirements
temperature
(-40~100)℃
±1℃
humidity
0%RH~100%RH
±3%RH
wind direction
0°~359°
±5°
wind speed
0m/s~30m/s
±1 m/s
atmospheric pressure
100hPa~1150 hPa
±10 hPa