Shanghai Cenxi Technology Co., Ltd
Home>Products>Hana pen acidity meter HI98128
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    16710276909
  • Address
    205, Building A, Yinzhou International Building, No. 258 Chengjiaqiao Road, Minhang District, Shanghai
Contact Now
Hana pen acidity meter HI98128
Hana pen acidity meter HI98128: suitable for on-site or laboratory use, easy to operate and affordable, in line with laboratory measurement standards.
Product details

Hana pen acidity meter HI98128Parameters:

Suitable for on-site or laboratory use, with simple and affordable operation, meeting laboratory measurement standards.
It has functions such as a large screen LCD, automatic recognition calibration, final measurement value identification, electrode diagnosis, automatic shutdown, etc. The endpoint measurement value is stable, and the screen will display the hourglass symbol during measurement. After the measurement reading is stable, the hourglass symbol disappears, and the pH electrode diagnosis function automatically diagnoses the status of the acidity electrode during calibration. When an Err error message appears on the display screen, it indicates that the acidity electrode needs to be cleaned or the acidity electrode is damaged, and the battery level is displayed and automatically shut down. When the battery level is low, the low battery indicator will be displayed, prompting timely battery replacement; The instrument can be set to automatically shut down in three modes: 8 minutes, 60 minutes, or disable. It is used for rapid measurement of acidity in trace samples or small bottle neck samples, and can replace acidity test strips.

Hana pen acidity meter HI98128Parameters:

HI98129 pH EC TDS - º C/º F analyzer

HI98130 pH EC TDS - º C/º F analyzer HI98131 pH EC TDS - º C/º F analyzer

Range pH: 0.00 to 14.00

Range pH: 0.00 to 14.00 Range pH: 0.00 to 14.00

Calibration pH: 1-2 point automatic recognition, built-in two sets of standard points

Calibration pH: 1-2 point automatic recognition, built-in two sets of standard points Calibration pH: 1-2 point automatic recognition, built-in two sets of standard points

Range EC: 0 to 3999 μ S/cm

Range EC: 0.00 to 20.00 mS/cm Range EC: 0.00 to 6.00 mS/cm

Range TDS: 0 to 2000 ppm (mg/L)

Range TDS: 0.00 to 10.00 ppt (g/L) Range TDS: 0 to 3000 ppm (500CF); 0 to 3999 ppm (700CF)

Calibration EC/TDS: Single point automatic recognition, built-in EC and TDS standard points

Calibration EC/TDS: Single point automatic recognition, built-in EC and TDS standard points Calibration EC/TDS: Single point automatic recognition, built-in EC standard points and fast calibration

TDS conversion factor: 0.45 to 1.00

TDS conversion factor: 0.45 to 1.00 TDS conversion factor: 0.5 (500 ppm) or 0.7 (700 ppm)

Range - º C/º F: 0.0 to 60.0 ° C (32.0 to 140.0 ° F)

Range - º C/º F: 0.0 to 60.0 ° C (32.0 to 140.0 ° F) Range - º C/º F: 0.0 to 60.0 ° C (32.0 to 140.0 ° F)

Standard configuration: HI73127 polypropylene direct insertion pH electrode and built-in EC electrode

Standard configuration: HI73127 polypropylene direct insertion pH electrode and built-in EC electrode Standard configuration: HI73127 polypropylene direct insertion pH electrode and built-in EC electrode

Other: BEPS battery detection function, HOLD key reading lock

Other: BEPS battery detection function, HOLD key reading lock Other: BEPS battery detection function, HOLD key reading lock

Scope: Laboratory, on-site, wastewater, water treatment and other general acidity testing

Scope: Laboratory, on-site, wastewater, water treatment and other general acidity testing Scope: Acidity testing on-site, hydroponics, greenhouses, agricultural applications, etc

PH ORP/mV - º C/º F analyzer

ORP/mV - º C/º F analyzer PH - º C/º F analyzer

HI98121-400.jpg

HI98128-400.jpg

HI98121 pH mV - º C/º F analyzer

HI98120 mV - º C/º F&HI98201 mV - Tester HI98128 pH - º C/º F analyzer
Range pH/ORP: -2.00 to 16.00 pH; ± 1000 mV HI98120 Range ORP: ± 1000 mV Range pH: -2.00 to 16.00

Calibration pH: 1-2 point automatic recognition, built-in two sets of standard points

HI98201 Range ORP: ± 999 mV Calibration pH: 1-2 point automatic recognition, built-in two sets of standard points
Range - º C/º F: -5.0 to 60.0 ° C (23.0 to 140.0 ° F) Calibration ORP: Factory default calibration Range - º C/º F: -5.0 to 60.0 ° C (23.0 to 140.0 ° F)
Standard configuration: HI73127 polypropylene direct insertion pH electrode and built-in ORP electrode HI98120 range - º C/º F: -5.0 to 60.0 ° C (23.0 to 140.0 ° F) Standard configuration: HI73127 polypropylene direct insertion pH electrode
Other: HOLD key reading lock, battery detection reminder, automatic shutdown HI98120 standard configuration: HI73120 polypropylene direct insertion ORP electrode Other: HOLD key reading lock, BEPS battery detection, automatic shutdown
Scope: Laboratory, on-site, wastewater, water treatment and other general acidity testing Scope: Laboratory, on-site, wastewater, water treatment and other general acidity testing Scope: Laboratory, on-site, wastewater, water treatment and other general acidity testing

PH - º C/º F analyzer Acidity pH analyzer

HI98127-400.jpg

HI98127 pH - º C/º F analyzer

HI98108&HI98118 pH - º C/º F measuring instruments HI98100&HI98115 acidity pH analyzer

Range pH: -2.0 to 16.0

Range pH: 0.00 to 14.00 Range pH: 0.00 to 14.00

Calibration pH: 1-2 point automatic recognition, built-in two sets of standard points

Calibration pH: 1-2 point automatic recognition, built-in 4.01/7.01/10.01 pH standard points Calibration pH: 1-2 point automatic recognition, built-in 4.01/7.01/10.01 pH standard points

Range - º C/º F: -5.0 to 60.0 ° C (23.0 to 140.0 ° F)

Range - º C/º F: 0.0 to 50.0 ° C (32.0 to 122.0 ° F) Standard configuration: HI1271 polypropylene direct insertion pH electrode, specification: ∅ 8 × 103mm

Standard configuration: HI73127 polypropylene direct insertion pH electrode

Standard configuration: Built in replaceable dialysis membrane composite acidity pH electrode [non replaceable] Other: Stable reading indicator, battery detection reminder, automatic shutdown

Other: HOLD key reading lock, BEPS battery detection, automatic shutdown

Other: Stable reading indicator, battery detection reminder, automatic shutdown HI98100 [Red]; HI98115 [White]

Scope: General acidity testing on site, wastewater, water treatment, etc

Scope: Laboratory, on-site, hydroponic, water treatment and other general acidity testing Scope: Laboratory, on-site, hydroponic, water treatment and other general acidity testing

Acidity pH analyzer

HI98107-400.jpg

HI98103-400.jpg

HI981030-400.jpg

HI98107 acidity and pH analyzer

HI98103 acidity and pH analyzer HI981030 Acidity pH Tester 【 Suitable for Agriculture/Soil Industry 】

Range pH: 0.0 to 14.0

Range pH: 0.0 to 14.0 Range pH: 0.0 to 14.0

Calibration pH: 1-2 point automatic recognition, built-in 4.0/7.0/10.0 pH standard points

Calibration pH: 1-2 point automatic recognition, built-in 4.0/7.0/10.0 pH standard points Calibration pH: 1-2 point automatic recognition, built-in 4.0/7.0/10.0 pH standard points

Range - º C/º F: 0.0 to 50.0 ° C (32.0 to 122.0 ° F)

Standard configuration: HI1271 polypropylene direct insertion pH electrode, specification: ∅ 8 × 103mm Standard configuration: Built in detachable sheath composite acidity pH electrode [non replaceable]

Standard configuration: Built in replaceable dialysis membrane composite acidity pH electrode [non replaceable]

Power supply: CR2032 button lithium battery, 8, 60 minutes or disable automatic shutdown Power supply: CR2032 button lithium battery, 8, 60 minutes or disable automatic shutdown

Other: Stable reading indicator, battery detection reminder, automatic shutdown

Other: Stable reading indicator, battery detection reminder, automatic shutdown Other: Stable reading indicator, battery detection reminder, automatic shutdown

Scope: General acidity testing on site, wastewater, water treatment, etc

Scope: Laboratory, on-site, hydroponic, water treatment and other general acidity testing Scope: Acidity testing in laboratory, on-site, agricultural, soil and other industries

HI981031-400.jpg

HI981032-400.jpg

HI981033-400.jpg

HI981031 Acidity pH Tester 【 Suitable for Beer/Brewing Industry 】

HI981032 Acidity pH Tester 【 Suitable for Cheese Industry 】 HI981033 Acidity pH Tester 【 Suitable for the Wine Industry 】

Range pH: 0.0 to 14.0

Range pH: 0.0 to 14.0 Range pH: 0.0 to 14.0

Calibration pH: 1-2 point automatic recognition, built-in 4.0/7.0/10.0 pH standard points

Calibration pH: 1-2 point automatic recognition, built-in 4.0/7.0/10.0 pH standard points Calibration pH: 1-2 point automatic recognition, built-in 4.0/7.0/10.0 pH standard points

Standard configuration: Titanium sheathed glass composite acidity pH flat head electrode [non replaceable]

Standard configuration: PVDF material composite acidity pH conical electrode [non replaceable] Standard configuration: CPS ™ Sheath glass composite acidity pH electrode [non replaceable]

Power supply: CR2032 button lithium battery, 8, 60 minutes or disable automatic shutdown

Power supply: CR2032 button lithium battery, 8, 60 minutes or disable automatic shutdown Power supply: CR2032 button lithium battery, 8, 60 minutes or disable automatic shutdown

Other: Stable reading indicator, battery detection reminder, automatic shutdown

Other: Stable reading indicator, battery detection reminder, automatic shutdown Other: Stable reading indicator, battery detection reminder, automatic shutdown

Scope: Acidity testing in laboratory, on-site, beer, brewing tower and other industries

Scope: Acidity testing in laboratory, on-site, yogurt, cheese, semi-solid and other industries Scope: Acidity testing in laboratory, on-site, wine and other industries

HI981034-400.jpg

HI981035-400.jpg

HI981036-400.jpg

HI981034 Acidity pH Tester 【 Suitable for Milk Industry 】

HI981035 Acidity pH Tester 【 Suitable for Paper and Leather Industries 】 HI981036 Acidity pH Tester 【 Suitable for Meat Industry 】

Range pH: 0.0 to 14.0

Range pH: 0.0 to 14.0 Range pH: 0.0 to 14.0

Calibration pH: 1-2 point automatic recognition, built-in 4.0/7.0/10.0 pH standard points

Calibration pH: 1-2 point automatic recognition, built-in 4.0/7.0/10.0 pH standard points Calibration pH: 1-2 point automatic recognition, built-in 4.0/7.0/10.0 pH standard points

Standard configuration: Glass composite acidity pH conical electrode [non replaceable]

Standard configuration: Glass composite acidity pH flat head electrode [non replaceable] Standard configuration: PVDF material composite acidity pH conical electrode [non replaceable]

Power supply: CR2032 button lithium battery, 8, 60 minutes or disable automatic shutdown

Power supply: CR2032 button lithium battery, 8, 60 minutes or disable automatic shutdown Power supply: CR2032 button lithium battery, 8, 60 minutes or disable automatic shutdown

Other: Stable reading indicator, battery detection reminder, automatic shutdown

Other: Stable reading indicator, battery detection reminder, automatic shutdown Other: Stable reading indicator, battery detection reminder, automatic shutdown

Scope: Acidity testing in laboratory, on-site, milk and other industries

Scope: Laboratory, on-site, paper industry, leather, skin and other industries acidity testing Scope: Acidity testing in laboratory, on-site, meat and other industries
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!