TG-61320C High and Low Temperature Impact Test ChamberPurpose of instrument and equipment:
The high and low temperature impact test chamber is used to test the degree to which material structures or composite materials can withstand continuous environments of extremely high and low temperatures in an instant, in order to test the chemical changes or physical damage caused by thermal expansion and contraction in the shortest possible time. Applicable objects include automotive electronics/Components, LED/LCD/PDP display lighting, new energy/electronic components/appliances, plastics/rubber/films, scientific research/quality inspection/universities/medical equipment, PCB/FPC/HDI/MPCB/IC and other industry materials can serve as a basis and reference for product quality verification or improvement.
TG-61320C High and Low Temperature Impact Test ChamberApplicable to standards:
1:GB/T 10592-2008 Technical Conditions for High and Low Temperature Test Chambers;
2:GB/T 2423.1-2008 Environmental testing for electrical and electronic products - Part 2: Test methods - Test A: Low temperature (IEC 60068-2-1:2007, IDT);
3:GB/T 2423.2-2008 Environmental testing for electrical and electronic products - Part 2: Test methods - Test B: High temperature (IEC 60068-2-2:2007, IDT);
4:GB/T 2423.22-2012 Environmental Testing Part 2: Test Methods Test N: Temperature Variation (IEC 60068-2-14:2009, IDT);:
5:GJB 150.3-86 Environmental Test Methods for Military Equipment Part 3 High Temperature Test;
6:GJB/T 150.4-2009Environmental testing methods for military equipment 第4 parts of low temperature test;:
7:GJB/T 150.5-86 Environmental Test Methods for Military Equipment Part 5 Temperature Shock Test.
TG-61320C High and Low Temperature Impact Test ChamberProduct Features:
1: The new generation of Tai Gui instrument productionHigh and low temperature impact test chamber(2 boxes)The box structure, refrigeration system, and control technology have undergone significant technological reforms, resulting in more reliable operation and easier maintenance.
2:The refrigeration machine adopts知名genuineImportTaikangorBizelle.
3:controlThe system adoptsColor touch screen display in both Chinese and EnglishTouch-toneoperation,The appearance is simpler and more elegant,The operation setting is simple.
4:The basket is switched and transferred between high and low temperature chambers using pneumatic control. The conversion time is short, the temperature recovery time is short, the temperature change speed is fast, the overall structure of the equipment is compact, and the volume is small. The two box method is used to improve the temperature uniformity range of the working chamber. However, the test piece is always in motion, and the working chamber cannot have test holes, so it cannot be charged, have signals, or have gas sourcesmeasureTry.
5:Equipment for high and low temperature impact test chamberSD card storage, USB output, computer connected printing, large cabin with paperless recording and other optional features.
6: Box processingIt is processed and formed using CNC machine tools, with a beautiful and elegant appearance, and adopts a non reactive handle for easy operation.housingadoptHigh quality carbon steel platePhosphating electrostatic spraying treatmentOr (optional)SUS304 stainless steel matte surface line hairline treatment,All internal materials are made ofSU304 high-grade stainless steel material.
7:thermal shock chamberequipLarge observation window attachedinternational brandThe lighting fixtures keep the inside of the box bright and use tempered glass embedded in the heating body to observe the condition of the box clearly at all times.
TG-61320Cthermal shock chamberTechnical Specifications:
Device Model |
Studio size (mm) |
Dimensions (mm) |
volume |
note |
Total power of the power supply |
|
TG-61320A |
350x350x400 |
1100x2400x1800 |
50 L |
Experimental volume can be customized according to customer requirements |
380v/7kv |
|
TG-61320B |
500x400x500 |
1400x2500x1800 |
100 L |
380v/8.5kv |
||
TG-61320C |
500x500x600 |
1500x2600x1850 |
150 L |
380v/9.5kv |
||
TG-61320D |
600x500x700 |
1700x2650x1900 |
210 L |
380v/9.5kv |
||
TG-61320E |
800x800x800 |
2500x3200x2100 |
512 L |
380v/13kv |
||
TG-61320F |
1000x1000x1000 |
3000x3500x2100 |
1000 L |
380v/15kv |
||
TG-61320G |
1500x1000x1000 |
4000x4200x2200 |
1500L |
380v/20kv |
||
temperature |
high-temperature chamber |
RT~200℃ |
||||
Low-temperature chamber |
RT~-70℃ |
|||||
Impact temperature range |
-40℃、-50℃、-60℃~ 120 ℃ and 150 ℃ can be selected as needed |
|||||
Temperature fluctuation ≤ ± 0.5 ℃ |
Temperature uniformity ≤± 2 ℃ |
Noise dB ≤ 65 |
||||
ramp rate |
warm up |
60min/RT~200℃ |
||||
cool down |
60min/0~70℃ |
|||||
temperature conversion |
The test piece basket is switched and transferred between high and low greenhouses for dynamic operation |
|||||
Experimental method |
Transfer method of test piece |
Pneumatic specimen transfer time: ≤ 5s |
||||
Temperature recovery time |
≤5min |
|||||
refrigeration |
system |
French fully enclosed Taikang compressor/or Bizelle compressor, single/stacked refrigeration |
||||
refrigerant |
1:R~404A 2: R-23 (fluorine free) 3; Tai Gui R&D refrigerant (stable and excellent) |
|||||
cooling |
Air cooling/water cooling optional |
|||||
sensor |
temperature |
A-grade platinum resistor A (PT100) or digital sensor (optional) |
||||
humidity |
A-grade platinum resistor A (PT100) or digital sensor (optional) |
|||||
control |
Original temperature control instrument, easy to operate, convenient to set, control accuracy of 0.01 ℃, exceeding 1200 programming segments. |
|||||
Standard Configuration |
SUS304Board storage rack (second floor) |
|||||
safety protection |
Compressor overheating, overpressure, overtemperature, fan motor overheating, overall equipment under phase/Reverse phase overall equipment timing, leakage protection, overload and short circuit protection |
|||||
note |
Tai Gui Company can customize products according to customer requirements. |
|||||