Product Description:
Tie a dry or damp white cotton cloth on the surface of the friction hammer of this machine, rub the colored test piece with a certain load and frequency, and compare it with the gray mark to evaluate the dye friction firmness level It can also be used as a friction test for organic solvents
Reference standard:JIS-L0801, 0823, 0849, 1006, 1084, K6328, P8136
Machine specifications:
Friction speed: 30cpm
Friction hammer load: 200g
Auxiliary load: 300g
Friction hammer size: 45 × 50mm
Test piece: 22 × 3cm
White cotton fabric: 5 × 5cm
Machine weight: approximately 58kg
Friction area of white cotton cloth: 1 square centimeter
Friction distance: 100mm
Counter: Electronic 6-digit number
Number of friction groups: 6 groups
Power supply: 220V
Machine size: approximately 50 × 55 × 35cm

Inspection standards:
The staining determination of white cotton cloth for friction shall be carried out in accordance with the provisions of Article 9 (Determination of Color Fastness) of JIS L 0801.
According to the test results, the following judgments are made
Excellent: The wet cloth test leaves no color on the white fine cloth.
B Shangjia: There is color retention on the white fine cloth during the wet cloth test, but no color retention on the white fine cloth after the dry cloth test.
C Defect: After the dry cloth test, the white fine cloth retains color.
Test steps:
1. Plug in the power supply (AC220V, 3A);
2. Turn on the power switch
3. Set the required number of experiments on the counter
Schematic diagram of operation panel

POWER:Power button, turn on/off the power of the instrument
RUN:Start button
STOP:Stop button
CLR:Reset key to reset the value to zero
SET:Set key, transition from normal state to modified state, modify test times, and finally confirm and return to normal state.
↑ Numerical increment key
↓ Numerical decrement key
← Left Shift Key
→ Right shift key

Figure 3
As shown in the picture:
SP:test speed
TM:The set number of tests
ADD TIMES:Actual number of tests
Turn on the power and pressSETKey, display window as shown in the following figure

Figure 4
Press the ↑↓ keys again to change the counting method, where O is positive and 1 is negative
Press the ← → key again to enter the set number of times to modify, and move to the corresponding position that needs to be modified
Use the ↑↓ keys to increase or decrease, set the required number of tests, and then pressSETPress the key to exit the modification state. After setting, pressRUNThe key starts the test, and the instrument automatically stops after completing the set number of movements. If you need to stop halfway, pressSTOPThe key. press againRUNContinue testing with the key. Before conducting the next test, the following steps should be takenCLRPress the key to reset the record to zero.
4. When the number of experiments reaches the set value, the machine stops
5. Repeat the test for the next product or turn off the power
At the end of the test, record the test results
|
Attention If an emergency situation requires stopping the machine, press the STOP button to stop the testing work. |
6. If any abnormalities are found during the testing process, please stop the machine in a timely manner and disconnect the power if necessary. During the testing process, users are not allowed to leave their posts without authorization