Shanghai Shifu Air Technology Co., Ltd
Home>Products>Japanese style dry mist humidifier
Japanese style dry mist humidifier
Japanese style dry mist humidifier
Product details

Shifu's new dry mist humidifier

principle

Dry mist industrial humidifiers use the siphon vacuum principle of nozzles to operate. Compressed air forms a negative pressure vacuum when sprayed, which then attracts water from the waterway to the nozzle nozzle and mixes it with compressed air to form ultrafine dry mist particles, thus achieving the purpose of humidifying the working environment. The nozzle of the humidification system is manufactured using a unique production process, drawing inspiration from relevant Japanese technology,When the air pressure is 0.3Mpa, the spray amount of one nozzle can reach 2.4L/H, and a single unit * can install more than four nozzles, which is very suitable for humidification in a narrow space and will not wet the wall.

filename


Technical Parameter


[Product Features]

-High performance industrial humidifier, operating at an air pressure ofAt 0.3MPa, the maximum humidity can reach up to 9.6L/H

-The spray distance of the nozzle can reachHigh quality spray of more than 4M, with remarkable humidification effect

-Adopting ultra small water storage tanks that are difficult for bacteria to reproduce, to avoid secondary pollution

-Non clogging nozzle, quick detachable and easy to maintain

-Intelligent automatic control of the system can be achieved through timers and controllers

-If equippedShifuPure water treatmentdevice, then there is no need to clean the humidifier

-In conjunction with the intelligent aerosol host, intelligent control can be achieved, providing 485 protocol and upper computer software

wisdomabilityControl System Description1. In order to maintain the stability and long-term performance of the entire humidification system, a Siemens PLC control system is used to stably control the water and gas supply of the current humidification system. The system has the functions of variable frequency voltage regulation for water supply, processing and filtering for gas supply, and functional expansion.

2. Adopting Swiss Weituo sensors, it has high precision and high display of temperature and humidity in the workshop.3In order to prevent possible dripping during humidification in the future, the water system in the host system also has electromagnetic clearance function.4. When abnormal water and gas pressure occurs, the host has an alarm function, which facilitates personnel to check the situation in a timely manner. The humidification host has computer functional self checking capability, which can provide alarms and warning reminders for problems that exist in the entire system.



Product accessory diagram


undefined

Installation example diagram






Precautions for using a dry mist humidifier

1. No need for liquid pressure control unit, the required water pressure is 0.5-3 bar;

2. If there is a leak in the nozzle or piping system, or similar hazardous factors may exist, please stop using it;

3. Ensure that the water and gas pipes are firmly connected and have good sealing to prevent air and water leakage;

4. When the dry fog humidifier stops spray, the water circuit must be closed first, and then the air circuit must be closed after an interval of 1 minute;

5. Install the dry mist humidifier horizontally and do not place any other objects in close proximity directly below the nozzle;

6. Maintain an air pressure of 1-4 bar, a water pressure of 0.5-3 bar, and a pressure resistance of 8 bar for the connecting hose. Excessive air pressure can cause the nozzle to detach from the pipeline. Excessive water pressure can cause water leakage in humidifiers, and a pressure reducing valve can be used to lower the water pressure;

7. Do not open the humidifier when there is air or water pressure present;

8. Do not use in the following environment. The ambient temperature is above 60Directly exposed to the sun or rain;

 9Please confirm if there is any water leakage in the equipment;

 10Do not disassemble or assemble the nozzle without proper maintenance;

 11If the temperature and humidity are automatically controlled, the air compressor needs to be constantly in the on state.

Daily maintenance methods for dry mist humidifiers

1. Regularly inspect and clean filtering equipment such as air filters and water filters to avoid blockages that may affect the supply of air and water sources. The cycle is once a month or more;

2. Regularly check whether the water and gas pipelines are blocked by dirt, with a cycle of once a month or less;

3. Regular useDry mist humidifierComes with a small tool to clean the nozzle hole and internal filter screen of its waterway, avoiding blockage by dirt.



Shanghai Shifu Air Technology Co., Ltd

Urban Road, Minhang District, ShanghaiRoom 305, Lane 384

Telephone:

Fax:

Sun Baojun:

Website: www.____shifuair.com





Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!