Zhejiang Xinou Automatic Control Instrument Co., Ltd
Home>Products>KLP series pneumatic quick installation single seat regulating valve
KLP series pneumatic quick installation single seat regulating valve
Technical parameters: KLP series single seat regulating valve adopts a top guided unbalanced structure, with high strength, heavy load, S-shaped strea
Product details

Introduction to Pneumatic Control Valve

The KLP series pneumatic quick installation single seat regulating valve adopts a top guided unbalanced structure, with high strength, heavy load, S-shaped streamlined channel, low pressure drop loss, large flow coefficient, wide adjustable range, and high precision of flow characteristics. This regulating valve is suitable for heavy loads, normal or harsh working conditions, with tight closure, suitable for controlling fluids or gases of various pressures and temperatures, and adaptable to various actuators, playing a regulating role. The quick installation valve cage compression valve seat design reduces lateral load and valve core vibration, reduces friction, and extends the service life of the control valve. Flow open design, the flow direction of the medium tends towards the direction of the control valve opening, and the controllability of small flow states is good. According to the working conditions, special valve cages that reduce noise and resist cavitation can be selected

※ Product specifications for pneumatic control valves

canonical name

Industrial Control Valve

Structure length

Flange standard

pneumatic control valve

Pressure and temperature rating

international standard

IEC 60534-1

IEC 60534-3-1

ASME B16.5

IEC 60534-4

ASME B16.34

national standard

GB/T17213

GB/T17213.3

JB/T79, HG/T20592, etc

GB/T4213

GB/T9131

Main parameters of pneumatic control valve body

Form

Top guided straight through single seat valve

Nominal Diameter

DN20~DN300

nominal pressure

PN16、40、63、100,ANSI CL150、300、600

Valve body and valve cover material

WCB, WC6, WC9, CF8, CF8M, HC276, Ti alloy, etc

Material of valve internals

304, 316, HC276, Ti alloy, etc

Packing material

PTFE V-shaped, flexible graphite, PTFE packing, flexible graphite with nickel wire

actuator

Pneumatic, electric, hydraulic

Connect with the actuator

Bolt compression type, round nut locking type

Valve cover type

Standard type, high temperature type, low temperature type, corrugated pipe type

Connection method

Flange type (RF, MFM, RJ), welded type (SW, BW)

flange distance

See the table below

operation temperature

-29~+230 (standard),+230~+560 (medium high temperature), -30~-196 (low temperature, ultra-low temperature)

Leakage level

ANSI B16.104 IV、VI、 Zero Leakage

Traffic characteristics

Equal percentage, linear, switch

Inherent adjustable ratio

50:1

※ Pneumatic control valve structure length (flange distance)

Nominal Diameter

20

25

32

40

50

65

80

100

125

150

200

250

300

Flange distance L

PN16、25

184

184

200

222

254

276

298

352

410

451

543

673

737

PN40

194

197

210

235

267

292

317

368

425

473

568

708

775

PN63、100

206

210

220

251

286

311

337

394

440

508

610

752

819

Rated flow coefficient and stroke of pneumatic control valve

Nominal Diameter

20

25

32

40

50

65

80

100

125

150

200

250

300

Valve seat diameter

20

25

32

40

50

65

80

100

125

150

200

250

300

Rated Cv

linear

7

14

20

30

44

68

110

175

275

440

690

1000

1600

Equal percentage

6.3

10

17

25

40

63

99

160

250

360

640

900

1440

rated travel

16

25

40

60

100

Note: For DN250 and DN300, it is recommended to use a balanced cage valve. When using a small pressure difference, a single seat valve can be selected (please consult the company's technical service center for details)

For valve seat diameters below 20mm, please refer to the Small Flow Valve Manual

※ Installation precautions


In order to ensure the normal operation of the regulating valve during start-up and ensure the safe operation of the system for the newly designed and installed control system, the nameplate markings on the valve should be checked for compliance with the design requirements before installation. At the same time, the following items should also be debugged: basic error limit; Full journey deviation; Return difference; Dead zone; Leakage rate (when strictly required).

If the control valve in the original system is overhauled, in addition to the calibration of the above items, the sealing inspection shall also be carried out on the stuffing box and connection of the old valve.

In the use of regulating valves, many of them are often not caused by the quality of the regulating valve itself, but by improper installation and use of the regulating valve, such as improper installation environment, installation position and direction, or unclean pipelines. Therefore, attention should be paid to the following aspects when installing and using regulating valves:

(1) The regulating valve is a field instrument, and it is required that the ambient temperature should be within the range of -25 to 60 ℃ and the relative humidity should be ≤ 95%. If installed outdoors or in high-temperature environments, waterproof and cooling measures should be taken. In areas with seismic sources, it is necessary to stay away from the source or increase anti vibration measures.

(2) Regulating valves should generally be installed vertically, and in special cases, they can be tilted. For example, if the tilt angle is too large or the valve itself weighs too much, supporting components should be added to protect the valve.

(3) The pipeline for installing regulating valves should generally not be too high above the ground or floor. When the pipeline height is greater than 2 meters, a platform should be set up as much as possible to facilitate the operation of the handwheel and maintenance.

(4) Before installing the regulating valve, the pipeline should be cleaned to remove dirt and welding slag. After installation, in order to ensure that impurities do not remain in the valve body, the valves should be cleaned again. That is, when introducing the medium, all valves should be opened to prevent impurities from getting stuck. After using the handwheel mechanism, it should be restored to its original neutral position.

(5) In order to enable the production process to continue in case of malfunction or maintenance of the regulating valve, a bypass pipeline should be added to the regulating valve, and special attention should be paid to whether the installation position of the regulating valve meets the requirements of the process.

(6) The installation of the electrical part of the regulating valve should be carried out according to the relevant electrical equipment construction requirements. If it is a flameproof product, it should be installed according to the requirements of the "Installation Specification for Electrical Equipment in Explosive Hazardous Areas". During use and maintenance, it is strictly prohibited to use electricity to open the cover for repair and to strike the explosion-proof surface in explosive areas. At the same time, do not damage or scratch the explosion-proof surface during disassembly and assembly, and restore it to its original explosion-proof state after maintenance.

(7) After disassembling and repairing the actuator, attention should be paid to oiling and lubrication. Generally, low-speed motors should not be disassembled, washed, or oiled. After assembly, it is also necessary to check whether the valve position matches the valve opening indication.

morepneumatic control valvePlease click here for installation instructions

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!