English

Beijing Jiahua Zhongxin Technology Co., Ltd
Home>Products>Kane 9206 Smoke Analyzer from the UK
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13671068345
  • Address
    Tiantong Xiyuan Third District, Dongxiaokou Town, Changping District, Beijing
Contact Now
Kane 9206 Smoke Analyzer from the UK
1、 Product Introduction: The new version of kane9206 Quintox is a new flue gas analyzer and emission monitor developed on the basis of the original ka
Product details

1、 Product Introduction:
The new version of kane9206 Quintox is a new flue gas analyzer and emission monitor developed on the basis of the original kane9106. KM9206 not only retains all the functions of KM9106, but also utilizes flexible modular system design and standard complete configuration to provide users with a complete monitoring solution platform.
The KM9206 comprehensive flue gas analyzer uses six electrochemical sensors to monitor the emission concentrations of carbon monoxide, nitric oxide, nitrogen dioxide, sulfur dioxide, hydrogen sulfide, and oxygen, and combines infrared measurement technology to complete the concentration monitoring of carbon monoxide (10%), carbon dioxide, and hydrocarbons.

2、 Product features:
1. Through TUUML; V SUUML; D EM50379 certification
2. Can monitor the emission concentrations of O2, CO, NO, NO2, SO2, H2S, CO2, and HC
3. Combination of 5 additional electrochemical sensors and 1 infrared sensor
4. Large format display of 15 lines of text/data
5. Provide wireless/USB cable connection to PC
6. GPS positioning function
7. KANE LIVE software provides real-time analysis of monitoring data
8. Can store 64000 test data
9. Allow the probe to reset the sensor in the flue
10. Sensor overload protection function ensures the service life of the sensor
11. Powerful gas pump
12. Optional all-in-one printer or external infrared printer
13. Detachable multi specification probe, suitable for different flue environments

3、 Technical parameters:
Project resolution accuracy range overload protection
Measure O2 0.1% -0.1%+0.2% 0-25% 30%
CO 1ppm ±5ppm <100ppm
±5% >100ppm <2000ppm
±10% >2000ppm <4000pp 0~ 2000ppm 4000ppm
SO2(H) 1ppm ±5ppm <100ppm
±5% >100ppm <2000ppm
±10% >2000ppm <5000ppm 0 ~ 2000ppm 5000ppm
SO2(L) 1ppm ±5 <100ppm
±10% >100ppm <300ppm 0 ~ 100ppm 300ppm
NO(H) 1ppm ±5ppm <100ppm
±5% >100ppm <2000ppm
±10% >2000ppm <5000ppm 0 ~ 1000ppm 5000ppm
NO(L) 1ppm ±5 <100ppm
±10% >100ppm <300ppm 0 ~ 100ppm 300ppm
NO2 1ppm ±5 <100ppm
±10% >100ppm <1000ppm 0 ~ 100ppm 1000ppm
H2S 1ppm ±5ppm <100ppm
±5% >100ppm <200ppm
±10% >200ppm <300ppm 0 ~ 200ppm 300ppm
HC (IR) 1ppm ±5% 0 ~ 5000ppm 10000ppm
CO2 (IR) 0.1% ±5% 0 ~ 20% 40%
CO (IR) 0.1% ±5% 0 ~ 10% 20%
Smoke temperature 0.1 ℃+1 ℃± 0.3% 0-1100 ℃
Environmental temperature 0.1 ℃+1 ℃ 0-55 ℃
Supply air temperature 0.1 ℃+1 ℃± 0.3% 0-600 ℃
Pressure 0.01mbar+0.5% 0-150mbar
Calculate CO2 0.1%+0.3% 0-99.9%
NOx 1ppm +5ppm<100ppm
+5%>100ppm 0 ~6000ppm
Net temperature 0.1 ℃+1 ℃ 0-1100 ℃
Efficiency 0.1%+1.0% Reading 0-99.9%
Void coefficient 0.1%+0.2% 0-2885.0%
Loss of 0.1%+0.2% 0-99.9%
CO/CO2 0.0001 +0.01 0 ~0.9999
T90(S) <30s
Sampling pump 2L/min
Preheating time 3 minutes
Working temperature 5-50 ° C
Working humidity 10-80% RH
Handheld device 240 * 135 * 70mm
Host 420 * 345 * 225mm
Nickel hydrogen rechargeable battery (12V, 2AH)
Usage time 8 hours
Charging time 12 hours/4 hours fast charging
Probe KMCP6 285mm long 600 °

Optional KMCLP6 1m long 600 °, KMCHP6 285mm long 1000 °, KMCHLP6 1m long 1000 °, KHPURQ electromagnetic pump, WTS9206P drainage system, sensor heater, etc

Physical display


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!