Keithley 2000 Digital Multimeter
Product introduction: 18 measurement functions: DC voltage/current, AC voltage/current, AC and DC superimposed voltage/current, 2-wire/4-wire resistan
Product details
Product Introduction
·18 measurement functions: DC voltage/current, AC voltage/current, AC and DC superimposed voltage/current, 2-wire/4-wire resistance, frequency/period, dB and dBm, crest factor, spike, time scale, online current, RTD/thermocouple temperature measurement, lead resistance measurement.
·Simultaneous measurement and display of multiple parameters;
·Peak value, average value, and true effective value response;
·Data storage options include 8K/32K/128K;
·CMRR-140dB,NMRR-90dB;
·The integration period can be adjusted from 0.01-10PLC, with two types of digital filtering;
·Switch quantity 1 in and 4 out;
·Can set high and low limits, pass/fail indication;
·488 interface can directly drive the printer (hard copy of data);
·Trigger connection function, trigger delay<2 μ s;
·The rear panel slot can be equipped with a 10 channel scanning card or thermocouple temperature measurement card, as well as a 1801 nanovolt preamplifier.

Function Description

function describe
DC Voltage Range: 100.0000mV to 1000.000V
Resolution ranging from 0.1 μ V to 1mV
Basic accuracy of 35ppm+6ppm (90 days); 45ppm+10ppm (1 year)
resistance Range: 100000 Ω to 100000 M Ω
Resolution of 100 μ Ω~ 100 Ω
Basic accuracy of 80ppm+10ppm (90 days); 100ppm+10ppm (1 year)
Conduction Range 1k Ω
Test current 1mA
dc current Range 10mA~3A
Resolution 10nA to 10 μ A
Basic accuracy of 500ppm+40ppm (90 days); 800ppm+40ppm (1 year)
True RMS AC voltage (bandwidth 1Hz-2MHz)
Range: 100mV to 750V
Resolution 0.1 μ~1mV
Basic accuracy 0.03+0.015 (90 days); 0.05+0.015 (1 year)
True effective value AC current Range 1.000000A to 3.00000A
Resolution 1 μ A to 10 μ A
Basic accuracy 0.12+0.015 (90 days); 0.12+0.015 (1 year)
Diode display Range 3V~10V
Test current 1mA~100 μ A~10 μ A
Frequency/Period (1Hz-15M 0.03% reading)
DC flow rate (maximum reading/seven and a half digits 30; four and a half digits 2000)
system speed Range changed by 4.5ms
Function change 4.5ms
RTD temperature measurement ± 0.020 ℃ (90 days); ± 0.021 ℃ (1 year)
Thermocouple temperature measurement (J,K,T,E,R, ±0.5℃ )
DC online current (100 μ A 5%+2 words)