Large sand and dust test chamber
Product use: The large sand and dust test chamber is suitable for testing the sealing performance of product shells, mainly used for testing the IP5X
Product details
Equipment model | Studio size (D * W * H) mm | Dimensions (D * W * H) mm | |
LRHS-2000-PS | 1000×2000×1000 | According to the three views of the contract | |
---|---|---|---|
LRHS-4000-PS | 2000×2000×1000 | ||
LRHS-6000-PS | 2000×3000×1000 | ||
LRHS-8000-PS | 2000×2000×2000 |
Technical Parameter
Sales Hotline: 021-608 99999
sexually ability finger treetop |
Time setting range | Adjustable from 1 to 9999H | |||||
Airflow velocity | Not exceeding 2m/s | ||||||
Dust blowing method | ±0.5℃/±2℃ | ||||||
Sand and dust concentration | 2~4kg/m³ | ||||||
Experimental dust | Dry talcum powder, Portland cement, chimney ash, etc | ||||||
Vacuum pump flow control | 60~600L/H | ||||||
---|---|---|---|---|---|---|---|
Dust dehumidification | Electric heating for temperature rise and dehumidification | ||||||
Vibration time | 1S-99H adjustable | ||||||
Dust blowing time | 1S-99H adjustable | ||||||
Cycle period | Dust blowing time, stop time, and total time can be set arbitrarily | ||||||
Observation window | 395 × 395mm (effective field of view) | ||||||
send use material material |
External material | High quality A3 steel plate electrostatic spraying | |||||
Inner box material | Imported high-grade stainless steel SUS304 | ||||||
temperature controller | Taiwan Weilun 7.0-inch color touch instrument panel | ||||||
Standard configuration | Sample rack, dust scraper, talcum powder | ||||||
Select accessories | Vacuum system: rotary vane vacuum pump (equipped with vacuum pumping pipeline components) | ||||||
Safety protection | Fan motor overheating, overall equipment under/reverse phase, leakage protection Test timing, overload and short circuit protection, automatic shutdown after fault alarm |
||||||
supply voltage | AC380V±10% 50Hz | ||||||
Power | 4.5kW | 4.5kW | 6.0kW | 6.5kW | |||
Usage environment | 5℃~+28℃ ≤85% RH | ||||||
Note: 1. The test data were measured under good ventilation conditions at an ambient temperature of 25 ℃ 2. The above parameters are for reference only and can be customized according to the specific testing parameters of the user 3. This technical information is subject to change without prior notice |