Technical parameters of mask particle filtration rate tester:
1. Test flow range: 0L/min~100L/min, accuracy 2%
2. The cross-sectional area through which the airflow passes is 100cm ²
3. Resistance test range: 0~250Pa, accuracy up to 3Pa
4. Filter efficiency test range: 0~99.999%, resolution 0.001%
5. Test particle size: 0.3um
6. Aerosol: Sodium Chloride
7. Foggy dust source: NaCl
8. Test time: Resistance is tested separately for 5 seconds, while efficiency and resistance are tested simultaneously for 70 seconds
9. Structural composition: Imported aerosol generator, imported flow detection device, imported particle counter
10. Sample quantity: 1 route
11. Power supply: 220V, 50Hz, 1KW
12. Dimensions: (800mm x 700mm x 1450mm) (length x width x height)
13. Weight: Approximately 120Kg
The mask particle filtration efficiency testing machine meets the standards:
GB/T 19083-2010Technical requirements for medical protective masks5.4 Filtration efficiency
YY/T 0469-2011 Medical Surgical Masks 5.6.2 Particle Filtration Efficiency
GB/T 32610-2016 Technical Specification for Daily Protective Masks Appendix A Filtration Efficiency Test Method
GB 2626-2019 Respiratory Protection Self priming Filter Anti particle Respirator 6.3 Filtration Efficiency
GB 19082-2009 Technical Requirements for Medical Disposable Protective Clothing 5.7 Filtration Efficiency
EN 1822-3:2012 EN 149-2001
EN 14683:2005 IEST-RP-CC021.1 NIOSH 42 CFR Part 84, etc
The main features of the mask particle filtration rate tester are:
1. Dual particle counter, simultaneous detection before and after filtering(Optional photometer method for measurement)
2. 0.3um, 0.5um, 1.0um, 2.5um, 5.0um, 10.0um particle size particle filtration efficiency display;
3. Equipped with a 7-inch touch screen, the detection results are directly displayed on the interface, and users can choose to print, export, or save directly;
4. Efficiency testing: Imported brand high-precision dust particle counters or optical particle testers are used to detect upstream and downstream particle concentrations, ensuring accurate and stable sampling;
5. Flow detection: The system testing flow is mainly provided by dry and clean compressed air from the outside. Internally, there is a voltage and current stabilizing device installed to ensure the stability of the detected flow rate, and an automatic control system is used for simplicity, speed, and stability.
6. Resistance detection: The resistance pressure difference of the filter material will be obtained through the static pressure rings of its upstream and downstream testing chambers, and high-precision imported brand pressure difference transmitters will be used to ensure the accuracy and stability of the pressure difference;
7. Easy to operate: Users only need to place the sample in the fixture, press the button, adjust the test flow rate, and the system will automatically test the resistance and efficiency through the controller. The entire process is simple, fast, and efficient
Random accessories for mask filtration tester:
1. Oil mist generator
2. Flow meter
3. Pressure sensor
4. Particle counter
5. Control button
6. Touch screen display
7. Printer
8. Emergency close/open button
9. Vacuum pump
10. Flow control valve and on/off switch