industrymicroscopeECLIPSE LV100NDA and LV100ND
Equipped with both reflective and transmissive lighting, there are multiple mirror inspection methods to choose from. It can be paired with a digital camera and comes with a variety of accessories to meet the inspection and research needs of various industrial products and materials.
Modular design, available in both electric and manual versions
Designed with Nikon CFI60-2 optical system, the imaging is clear; Can be paired with a digital camera for photography; Modular design facilitates the expansion of various functions.
Nikon ECLIPSE LV100NDA and LV100ND
A microscope with both reflective and transmissive illumination, used for inspecting industrial materials and components, as well as product development.

Nikon CFI60-2 Optical Series Objective Lens
Nikon's innovative design supports clear and high contrast bright field, dark field, polarization (POL), differential interference (DIC) mirror inspection, as well as dual beam interferometry measurement.

Nikon Digital Sight digital camera
Nikon's entire range of Digital Sight digital cameras can efficiently take photos and transfer current parameters such as objective lens, magnification conversion settings, and illumination brightness to the NIS Elements microscope image processing software.

Product Highlights
Multiple microscopic examination methods
The available mirror inspection methods under reflected illumination include bright field, dark field, polarization (POL), differential interference (DIC), fluorescence, and dual beam interference;
The available mirror inspection methods under transmissive illumination include bright field, dark field, polarization (POL), differential interference (DIC), and phase difference.

Various accessories
There are multiple accessories available for users to choose from.
Stage, objective lens, objective lens converter, eyepiece, eyepiece tube, digital camera, filter and polarizer, etc.

Digital intelligent communication
LV100NDA can use Nikon image processing software to check the currently used objective lens, control electric objective lens conversion, illumination brightness, aperture action, mirror inspection mode switching, etc.
LV100ND can inspect and report the objectives used on LV-NU5I and LV-INAD.

Ergonomic Design
The use of an adjustable angle eyepiece tube allows the operator to observe the sample more comfortably and eliminate fatigue.
Mainly used for observing raw materials, semiconductors, and industrial components.

core functionality



size
| host: | Maximum sample height: 38 mm (when used with LVNU5AI U5AI objective converter and LV-S32 3x2 stage/LV-S64 6x4 stage) *When used with a 12V50W internal power supply on a pillar, the 73mm knob is used for dimming, coarse adjustment, and fine adjustment Left: coarse adjustment and fine adjustment/right: fine adjustment, 40mm stroke coarse adjustment: 14mm/rev (with torque adjustment and refocusing mechanism) Fine tuning: 0.1 mm/rev (1 μ m/scale), mounting hole spacing for stage: 70 x 94 (fixed with 4-M4 screws) |
| Objective lens converter: | C-N6 ESD six hole objective lens converter ESD LV-NU5 universal five hole object converter ESD LV-NBD5 BD five hole objective lens converter ESD LV-NU5I intelligent universal five hole objective lens converter ESD |
| 反射照明器: |
LV-UEPI-N LV-LH50PC12V50W pre centering light box light/dark field switch and link aperture stop (can be centered), field stop (can be centered) accept ø 25 mm filter (NCB11, ND16, ND4), polarizer/analyzer, plate, excitation light balancer; Equipped with a noise terminator LV-UEPI2 LV-LH50PC12V50W pre centering lightbox HG pre centering fiber optic lighting fixture: C-HGPIE (with dimming) * option with bright/dark field switch and linked aperture stop (can be centered), field stop (can be centered), automatic optical element switching function matching bright field, dark field, and falling fluorescence switch accepting ø 25 mm filters (NCB11, ND16, ND4), polarizer/analyzer, λ plate, excitation light balancer; Equipped with a noise terminator |
| Transmitting Illuminator |
LV-LH50PC12V50W preset lightbox (Fly Eye optical system) Internal aperture. Field aperture, filter (ND8. NCB11); Transmission/reflection selection switch; Also available is 12V100W (optional) |
| Eyepiece: |
LV-T13Three eye eyepiece tube ESD (upright image). FOV:22/25), LV-TT2TT2 tilted three eye eyepiece (upright image. FOV: 22/25). P-TBBinocular tube (inverted image, FOV: 22),P-TT2Triple tube (inverted image, FOV: 22) |
| Carrier platform: |
LV-S323x2 platform (travel: 75 x 50 mm, with glass plate) ESD compatible LV-S646x4 platform (travel: 150 x 100 mm, with glass plate) ESD compatible LV-S66x6 platform (travel: 150 x 150 mm) ESD compatible |
| Eyepiece: | CFI Eyepiece Series |
| objective lense: | industrymicroscopeCFI60-2/CFI60 Optical System Objective Series: Combination according to observation method |
| ESD 性能: | 1000 to 10V, within 0.2 sec. (excluding certain accessories) |
| Energy consumption: | 1.2A/75W |
| Weight: | Approximately 8.6kg |