Hangzhou Jiuhuan Fuqi Industrial Co., Ltd
Home>Products>Non standard automated testing
Non standard automated testing
Non standard automated testing is a testing equipment used in the fields of aviation, automotive, home appliances, scientific research, etc., to test
Product details

Non standard automated testingModel and Parameters

model Working size mm External dimensions in millimeters common ratio
JMS-100 450×450×500 1150×900×1650. 3.5KW
JMS-225 500×600×750 1200×1100×1900 4.5KW
JMS-500 700×800×900 1350×1280×2200 5.3 KW
JMS-800 800×1000×1000 1450×1480×2300 7 KW
JMS-010 1000×1000×1000 1650×1480×2300 7.5 KW
JMS-013 1000×1000×1300 1650×1480×2600 8.2KW

Non standard automated testingTemperature parameters:
Temperature range: 20 ℃ -80 ℃. Non standard test chambers and constant temperature laboratories can also be customized according to customer needs
Temperature fluctuation: ±0.5(When unloaded)
Temperature deviation: ≤± 2 ℃
Humidity range:4598% R? H
Humidity deviation: 2-3% R? H
Average rate of temperature rise and fall: 0.7 ℃~1.0 ℃/min (when unloaded)
Time setting range: 0-9999 hours
Power requirements:AC380V
Non standard automated testingCompliant with standards
This product meets the requirementsGB/T10588-2002Waiting for national standards, corresponding national and military standards; We can also manufacture non-standard products according to customer requirements.

The water tank of the constant temperature circulating water bath should be placed on a fixed platform, and the power supply voltage must be consistent with the required voltage of this product. The power socket should use a three hole safety inspection socket. A grounding wire must be installed, and clean water must be added to the sink to a height of 1/2-2/3. Turn the power switch to the temperature controller panel, and a digital display will show that the power is connected. Press the temperature button on the temperature controller, and the displayed temperature will be the actual measured temperature. Simultaneously rotate the temperature adjustment knob, observe the displayed value, and select the desired operating temperature. Press the setting button again, and the temperature displayed on the number is the temperature measured in the sink. The heat indicator light is on, and the instrument enters automatic temperature control mode. When the temperature in the constant temperature circulating water bath reaches the set temperature, the heating is interrupted and the heating indicator light is turned off. After being powered on for 60 minutes in a standard environment, the temperature can remain stable. When the required working temperature is low, a 2-time setting method can be used. If the working temperature is 39 degrees, set it to 36 degrees for the first time. When the temperature overshoot starts to fall back, set it to 39 degrees for the second time to strongly reduce the temperature overshoot phenomenon and enter a constant temperature state as soon as possible.