A p-type metal oxide H2S sensorH2S-A31 M31 P31Product Introduction
This sensor can respond well to extreme humidity and temperature environments in the oil and gas industry. In addition, the sensor is equipped with an integrated filtering device, which enables it toH2SSelective. Compared to commonnDifferent types of sensors, this metal oxide sensor has a large dynamic range, repeatable response, is less affected by humidity, and encountersH2SThe resistance will increase.
Sensors provided3Seed shell:TO-05The shell,6Needle plastic shell andExExplosion proof casing.
Bip type metal oxide H2S sensorH2S-A31 M31 P31Main features
1)Range:1-100ppm H2S
2)Sensor resistance(R0):220±50 kΩ(50% rh, 23 (±2)℃)
3)Sensor resistance(Rg):1900 ±500 kΩ( H2S@24ppm << span="">in air>)
4)Sensor resistance ratio(Rg/ R0*100%):860 ±250 % ( H2S@24ppm << span="">in air>)
5)Gas response relationship(Rg/Ro - 1 = k.Conc): 0.30 ± 0.09 ppm-1(5 - 30 ppm)
Gas response relationship (Rg/Ro - 1 = k.Conc): 0.24 ± 0.07 ppm-1(30 - 100 ppm)
6)Heater resistance(RH @ 23±1℃):10 ±1.5Ω
7)Heater resistance(RH @400±10℃):22 ±3Ω
8)Heater resistance(RH @ 525±10℃):26 ±3Ω
9)Heater power consumption(mW): 340 ±30 (400℃)(VH= 2.7±0.2V)
530 ±50 (525℃)(VH= 3.7±0.3V)
10)Working temperature:-20~120℃