PAP temperature control type
Product specification table PAP10A1 type PAP05A1PAP05A1-FPAP10A1PAP10A1-FPAP20APAP20A-F Possible temperature range for performance settings ※ 1 ℃ 18-3
Product details

Product specification table

PAP10A1

type PAP05A1 PAP05A1-F PAP10A1 PAP10A1-F PAP20A PAP20A-F
performance Set possible temperature range ※ 1 18 ~ 30
Temperature control accuracy ※ 2 ± 0.1
冷却+加熱能力 (50/60Hz) kW 2.3 / 2.6 4.7 / 5.3 9.4 / 10.5
(Cooling capacity) (kW) (1.6) / (1.8) (3.2) / (3.6) (6.5) / (7.2)
Freeze processing air volume ㎥/min 3 ~ 5 7 ~ 10 13 ~ 20
External static pressure ※ 3 Pa 110 620 250 560 250 690
environmental conditions Weekly temperature and humidity range (air absorption) * 1 ℃,% 15 ~ 35,30 ~ 70
Absorption temperature fluctuation hook ℃/h Within ± 1
吸込湿度変化勾配 %/h Within ± 5
External dimensions (height * depth * width) * 4 mm 1140×700×600 1423×700×600 1305×822×661 1565×822×661 1610×1150×770 2010×1150×770
product quality kg (130) (155) (185) (210) (290) (365)
Control the air vent mm φ 100 φ 100 HEPA Built in filter φ 150 φ 150 HEPA Built in filter φ 200 φ 200 ※ 5 HEPA Filter box
Electrical Characteristics Power supply ※ 6 V(Hz) Three phase 200 ± 10% (50/60)
Consumption of electricity ※ 7 kW 1.4 1.8 3.9
Current ※ 7 A 6.2 7.5 14.9
Power capacity ※ 8 kVA 2.2 2.6 5.2
Sound value (50/60Hz) * 9 dB 66/66 71/71 68/68 73/73 69/69 76/76
Operational control mode   Heat pump balance control
refrigerant   R410A
Output of refrigeration compressor kW 0.7 1.7 3.0

* 1 The controllable temperature range varies with suction air temperature and humidity. * 2 suction air temperature and humidity stability. Discharge point 1, controller display value accuracy. 3. External air pressure when the engine is operated by the control air outlet. * 4 height includes discharge port. ※ 5HEPA The filter box is separated from the main body, so it is necessary to install it.

6. 7 values within the specification range. 8 operating current within the specification range. 9 it is possible to lower the noise by taking out the noise absorption duct.

Please note that the connection duct must be insulated from the insulated duct. (recommended m Within