QL series ozone aging test chamber+model selection
1、 Product use: It can be used for rubber products such as vulcanized rubber, thermoplastic rubber, cable insulation sheaths, etc. Under static tension or continuous dynamic tension deformation, or under intermittent dynamic tension and alternating static tension deformation, it is exposed to sealed and unlit air containing a constant concentration of ozone and a constant temperature test chamber. The samples are tested for a predetermined time to evaluate the ozone aging resistance of the rubber by detecting the degree of cracking or other performance changes that occur on the surface of the samples.
2、 Model and parameters
| Product Model | QL-100 | QL-225 | QL-500 | QL-010 |
| Internal dimensions D × W × Hmm | 450×450×500 | 500×600×750 | 700×800×900 | 1000×1000×1000 |
| Dimensions D × W × Hmm | 1100×870×1600 | 1150×1020×1850 | 1350×1220×2000 | 1650×1420×2100 |
| temperature range | A:0℃~70℃、 B:RT+10℃~70℃(Instructions at the time of ordering) | |||
| humidity range | A:40%~98%R.H、B:85%~98%R.H | |||
| temperature fluctuation | ≤±0.5℃ | |||
| Temperature Uniformity | ≤±2℃ | |||
| temperature deviation | ≤±1.5℃ | |||
| Humidity fluctuation | +2、-3%R.H | |||
| heating rate | 0.7~1.0℃/min | |||
| 降温速率 | Reduce the room temperature to 10 ℃ ≤ 20min/unrestricted | |||
| ozone concentration | 10-1000pphm (low concentration), 1-500ppm (high concentration)Instructions for ordering | |||
| gas flow rate | 12~16mm/S | |||
| Ozone sample rack | Static and dynamic tensile test specimen racks | |||
| Sample rack speed | 360 degree rotating sample holder (rotation speed 1r/min) | |||
| Time setting range | 0-9999 hours | |||
| Power requirements | AC380 (± 10%) V/50HZ three-phase five wire system | |||
3、 Test method
Static tensile test
The standard stipulates that the two ends of the sample should be clamped on a fixture, and a tensile elongation of 20% should be selected. The fixture should be installed on a rotating sample holder with a rotation speed between (20-25) mm/S. The test should be conducted at a temperature of (40 ± 2) ℃, a relative humidity of no more than 65%, and a specified ozone concentration. Check the cracking condition of the sample after the specified time. The general selection of ozone concentration is (50 ± 5) × 10-8.
Dynamic tensile test:
The standard stipulates that the sample fixture can automatically stretch and reset the sample, with a stretching frequency of 0.5 ± 0.025Hz. The two ends of the sample are clamped on the fixture, and the sample is cyclically stretched from 0 to the maximum elongation. The fixture is installed on a rotating sample holder, with a rotation speed of (20-25) mm/S. At a temperature of (40 ± 2) ℃, a relative humidity of not more than 65%, and a specified ozone concentration, the fixture is cyclically stretched and reset and rotated with the sample holder for testing. After the prescribed time, check the cracking condition of the sample, and generally select an ozone concentration of (50 ± 5) × 10-8;
QL series ozone aging test chamber+model selection
4、 Ozone system:
1. The main component of the ozone generator is a silent discharge tube ozone generator (with the characteristics of small noise volume and high purity) with an output control accuracy of ± 10% for 4-20mA
2. Electrode cooling method: air cooling
3. Ozone generation gas source: direct air
4. The ozone detection probe consists of an imported CT electrochemical sensor, housing, electronic circuit board, shielded wire, etc
5. Ozone detection probe output signal: 4-20mA
6. Ozone detection probe collection accuracy: ≤± 5% F.S
5、 Refrigeration system:
1. Compressor: 1 set of fully enclosed French Taikang
2. Cooling method: air-cooled
3. Refrigerant: R404A, R23 (environmentally friendly)
6、 Box structure:
1. The shell is made of A3 steel plate, and the surface of the shell is treated with spray coating, making it more smooth and beautiful
2. The inner liner is made of mirror stainless steel plate
3. The bottom of the machine adopts high-quality fixed PU movable wheels
7、 Circuit control system:
1. 7.0-inch color touch screen controller
2. Accuracy: 0.1 ℃ (display range)
3. Resolution: ± 0.1
4. Temperature sensor: PT100 platinum resistance tester;
5. Control mode: thermal balance temperature regulation mode;
6. The temperature control adopts the coordinated control of the same channel by the P.I.D system
7. Equipped with automatic calculation function, it can reduce the inconvenience caused by manual setting
8. Ozone concentration control adopts imported Siemens PIC programmable module and PLC analog expansion module
9. Display: Equipped with a "4.3-inch" high-definition LCD screen
Free home delivery, after the installation and debugging of the equipment is completed, relevant technical personnel will receive free basic operation training at the user's site, with no limit on the number of people.