·Specifications and technical parameters of box type rain test chamber
model | LX-500 | LX-1000 | |
Studio size D × W × H | 800×800×800(mm) | 1020×1200×1000(mm) | |
sexually | Spray ring radius | 375 or 500 (mm) | |
pipe diameter | Φ16mm | ||
Orifice diameter | Φ0.4mm | ||
Aperture spacing | 50mm | ||
Pipe swing amplitude | ± 45 degrees, ± 60 degrees, ± 90 degrees, ± 180 degrees (theoretical values) | ||
Test bench speed | 1r/min can also be used for stepless speed regulation (optional) | ||
move | controller | Imported FM frequency converter | |
Time controller | Imported microcomputer time programmable integrated controller (Golden Bell Moller) | ||
Water pressure control | flowmeter | ||
Observation surface | Large area visualization tempered glass door | ||
Water supply system | Water storage tank, booster pump | ||
Safety protection | Leakage, short circuit, motor overheating |
For more products, please click on: High and low temperature test box, salt spray corrosion test machine, UV weather resistance test machine, high and low temperature humid heat alternating test box, xenon lamp weather resistance test box, high and low temperature low-pressure test box, rain test, sand and dust test box, vibration test bench, NM-T12TABER wear resistance test machine
The water tank of the constant temperature circulating water bath should be placed on a fixed platform, and the power supply voltage must be consistent with the required voltage of this product. The power socket should use a three hole safety inspection socket. A grounding wire must be installed, and clean water must be added to the sink to a height of 1/2-2/3. Turn the power switch to the temperature controller panel, and a digital display will show that the power is connected. Press the temperature button on the temperature controller, and the displayed temperature will be the actual measured temperature. Simultaneously rotate the temperature adjustment knob, observe the displayed value, and select the desired operating temperature. Press the setting button again, and the temperature displayed on the number is the temperature measured in the sink. The heat indicator light is on, and the instrument enters automatic temperature control mode. When the temperature in the constant temperature circulating water bath reaches the set temperature, the heating is interrupted and the heating indicator light is turned off. After being powered on for 60 minutes in a standard environment, the temperature can remain stable. When the required working temperature is low, a 2-time setting method can be used. If the working temperature is 39 degrees, set it to 36 degrees for the first time. When the temperature overshoot starts to fall back, set it to 39 degrees for the second time to strongly reduce the temperature overshoot phenomenon and enter a constant temperature state as soon as possible.