Xi'an Pinggao High Voltage Switchgear Manufacturing Co., Ltd
Home>Products>Sichuan customized 35KV high-voltage isolation switch
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    18049074494
  • Address
    Xi'an City
Contact Now
Sichuan customized 35KV high-voltage isolation switch
Description: Sichuan customized 35KV high-voltage isolation switch is not suitable for places with flammable substances, explosion hazards, chemical c
Product details

Sichuan customized 35KV high-voltage isolation switch

This series of products includes the following varieties:
1) Divided by the presence or absence of a grounding switch: ungrounded, single grounded (left and right grounded), and double grounded;
2) Grounding switches are classified into types I, II, and III based on their ability to withstand short-circuit currents;
3) Divided by usage area: ordinary type, anti fouling type, anti fouling type, and high-altitude type.
This series of products meets the requirements of standards and IEC standards, with good seismic resistance and the ability to meet the requirement of a seismic intensity of 9 degrees.
Sichuan customized 35KV high-voltage isolation switch
Conditions of Use
1. The altitude shall not exceed 1000m, and the plateau type shall not exceed 4000m;
2. Environmental temperature: -40 ℃ to+40 ℃;
3. Wind speed not exceeding 35m/s;
4. Earthquake intensity: 8 degrees;
5. Ice thickness: ≤ 10mm;
6. Anti pollution products are suitable for polluted areas;
7. Not suitable for places with flammable substances, explosion hazards, chemical corrosion, and severe vibrations.
Explanation: When the above environmental conditions cannot meet the usage requirements, it shall be resolved through negotiation between the user and the manufacturer.

Technical Parameter

Rated voltage KV: 40.5

Rated frequency Hz: 50/60

3 Rated current A: 630/1250/2500

4 rated short-circuit breaking current KA: 20/25/31.5

5 rated short-circuit current breaking times: 30

6 rated peak withstand current KA: 63/80

7 rated short-circuit closing current (peak) KA: 63/80

8 mechanical life cycles: 10000

9 4S short-time withstand current KA: 25/31.5

10 power frequency withstand voltage (1 minute): dry test (phase to phase, ground/fracture) KV: 80 95/95

11 lightning impulse withstand voltage (peak) phase to phase, relative/fracture KV: 185

12 rated operating cycles: on-off -0.1s-on-off -3s on-off -6-son-off -60s on-off -60s restoration

13 institutions control voltage AC/DC220

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!