Overview
Name |
ID |
Product Description |
Δpmax |
Δps |
threaded connection |
kvsRated flow coefficient when the valve is fully open |
nominal diameter |
|---|---|---|---|---|---|---|---|
MXG461.15-0.6 |
100325544 |
Continuous regulating three-way mixed flow/two-way electromagnetic regulating valve, threaded connection, PN16, DN15, kvs 0.6, AC 24 V |
300 kPa |
300 kPa |
G1B " |
0.6 m3/h |
15 |
MXG461.15-1.5 |
100325546 |
Continuous regulating three-way mixed flow/two-way electromagnetic control valve, threaded connection, PN16, DN15, kvs1.5, AC 24 V |
300 kPa |
300 kPa |
G1B " |
1.5 m3/h |
15 |
MXG461.15-3.0 |
100325548 |
Continuous regulating three-way mixed flow/two-way electromagnetic control valve, threaded connection, PN16, DN15, kvs 3, AC 24 V |
300 kPa |
300 kPa |
G1B " |
3 m3/h |
15 |
MXG461.20-5.0 |
100352212 |
Continuous regulating three-way mixed flow/two-way electromagnetic regulating valve, threaded connection, PN16, DN20, kvs 5, AC 24 V |
300 kPa |
300 kPa |
G1?B " |
5 m3/h |
20 |
MXG461.25-8.0 |
100325550 |
Continuous regulating three-way mixed flow/two-way electromagnetic regulating valve, threaded connection, PN16, DN25, kvs 8, AC 24 V |
300 kPa |
300 kPa |
G1?B " |
8 m3/h |
25 |
MXG461.32-12 |
100325551 |
Continuous regulating three-way mixed flow/two-way electromagnetic regulating valve, threaded connection, PN16, DN32, kvs 12, AC 24 V |
300 kPa |
300 kPa |
G2B " |
12 m3/h |
32 |
MXG461.40-20 |
100325552 |
Continuous regulating three-way mixed flow/two-way electromagnetic regulating valve, threaded connection, PN16, DN40, kvs 20, AC 24 V |
300 kPa |
300 kPa |
G2?B " |
20 m3/h |
40 |
MXG461.50-30 |
100325553 |
Continuous regulating three-way mixed flow/two-way electromagnetic regulating valve, threaded connection, PN16, DN50, kvs 30, AC 24V |
300 kPa |
300 kPa |
G2?B " |
30 m3/h |
50 |

function
BPZ:MXG461..
Continuous regulating electromagnetic control valve for chilled water or hot water, threaded connection
Two way valve or three-way mixed flow valve with electric magnetic actuator, PN16, Suitable for regulating and controlling chilled water or low-temperature hot water in closed-loop systems. Equipped with positioning control, valve position feedback signal, spring reset and manual adjustment functions.

technical specifications
rated pressure |
PN 16 |
Working Voltage |
AC 24 V |
Positioning signal |
DC 0...10 V; DC 2...10 V; DC 4...20 mA |
positioning time |
< 2 s |
Equipped with spring reset function |
A ->AB closed loop |
position feedback |
DC 0...10 V |
Protection level |
IP54 |
ambient temperature |
-5...45 °C |
Installation location |
Vertical to horizontal |
Allow work pressure |
1000 kPa |
leakage rate |
A -> AB: 0...0.02 % kvsvalue |
Bypass leakage rate |
< 0.2 % of kvsvalue |
medium temperature |
1…130 °C |
Valve flow characteristics |
Equal ratio; linear |
Travel accuracy Δ H/H100 |
1:1000 |
valve body |
Cast iron EN-GJL-250 |
Valve internal material |
Chromium nickel stainless steel, brass |
Technical Specifications Table |
N4455 |