HLZn1-1 typeZinc water qualityOnline monitoring analyzer
Working Principle:AtIn an aqueous solution with a pH of 4.0-5.5, zinc ions form a red chelate with dithizone, causing a change in the color of the mixture. The degree of color change in the solution is proportional to the zinc content in the water sample, and the zinc value of the water sample can be calculated by colorimetry.
Performance parameters:test scope (0.1-50) mg/L has automatic range switching function, which can achieve automatic measurement of water samples with different concentrations.
Actual water sample measurement error±10%
zero drift±5%(≤0.02mg/ L)
Span Drift±8%
reproducibility±3%
test cycle≤15min
Interface output Standard configuration:RS232/RS485、 Two 4-20mA channels;
volume 550 * 390 * 830mm (length * width * height)
weight 35kg
Application fields:Monitoring of Municipal Wastewater Discharge
Monitoring of sewage discharge from all polluting units
Water monitoring of natural environment in Rivers and Lakes
Environmental conditions:ambient temperature 5-40℃
relative humidity ≤85%
power supply voltage AC(220±22)V
voltage frequency (50±1)Hz
Instrument features:fully automatic operation
Having self diagnostic function
Low drug consumption, short preparation time
The amount of waste liquid in a single measurement is about9 milliliters
High definition touch screen display, easy to operate
After power failure, it has the functions of automatic startup and self-cleaning when receiving power
Long term self-control, low maintenance, and low operating costs
Fault alarm, easy to identify in a timely mannercause of failure、timelyTroubleshooting
equipdot matrix printerYes, yesmeasurementReal time data printing
Can set online automatic monitoring cycle and have online automatic calibration function; There are also specially designed for third-party operating companiesAutomatic calibration function for inspection.
