| Overview: |

The UBW series blind spot glass plate level gauge is a direct reading instrument widely used in the fields of petroleum, chemical, power, metallurgy, etc. to measure the liquid level in pressure vessels and open vessels.
| Main technical parameters: |
Center distance: ≤ 6000mm
(Can be specially made according to user needs)
● Nominal pressure: ≤ PN6.3MPa
Working temperature: 0-250 ℃
● Automatic sealing pressure: ≥ 0.3MPa
● Flushing and sewage interface: NPT1/2 "internal thread
(Can be specially made according to user needs)
● Heat tracing steam pressure: ≤ 1.0MPa
● Heat tracing jacket joint: G1/2 "external thread
(It can also be made according to user requirements)
| model | nominal pressure Mpa |
Relationship between medium temperature and working pressure | Liquid receiving material | ||||
| Working pressure Mpa |
Medium temperature ℃ | ||||||
|
UB(S)W-1
UB(S)W-2
UB(S)W-3
UB(S)W-4 |
|
2.5 | 250 | Class I: 20 25 25Mn Class II: 304 304L 316 316L 321 |
|||
| 4.0 | 200 | ||||||
| 3.6 | 250 | ||||||
| 6.3 | 200 | ||||||
| 5.4 | 250 | ||||||
| Product features: |
● No leakage, no blockage, and good sealing performance.
The liquid level display is clear, intuitive, without blind spots, uninterrupted, and continuous.
● It can achieve continuous indication of red and green colors without blind spots.
Simple structure, easy installation, operation, and maintenance, safe and reliable operation.
| Product Category: |
UB (S) W-1 blind spot transmission (dual color) glass plate liquid level gauge
UB (S) W-2 blind spot transmission jacket type (dual color) glass plate liquid level gauge
UB (S) W-3 blind spot reflective (dual color) glass plate level gauge
UB (S) W-4 blind spot reflection jacket type (dual color) glass plate liquid level gauge
UB (S) W-5 no blind spot transmission frost proof (dual color) glass plate liquid level gauge
UB (S) W-6 no blind spot reflection anti frost (dual color) glass plate liquid level gauge
| Connection process: |
● Flange connection: HG/T20592-2009 DN20
(Can be specially made according to user needs)
● Threaded connection: G3/4 "external thread
(Can be specially made according to user needs)
Note: When the center distance exceeds 1700mm, the instrument itself comes with a support bracket
| Structural principle: |
The UBW series blind spot glass plate level gauge is installed on the level gauge body with the observation glass staggered left and right. In this way, the blind spot between the two observation glasses of a regular glass level gauge is eliminated, achieving the goal of continuous indication throughout the entire measurement range. It is also possible to make a single row, front and rear staggered display without blind spots liquid level gauge, that is, the blind spots between the two sections on the front can be observed on the back, achieving full range without blind spots display.